Gebruiksaanwijzing /service van het product 360i van de fabrikant Rimage
Ga naar pagina of 27
Rimage 360i ™ User Guide This manual provides the information ne eded to operate the Rimage 360i and identify the parts. To set up and install your Rimage 360i, refer to the Rimage 360i Setup and Installation Gui de.
.
Corporate Headquarters: Rimage Corporation 7725 Washington Avenue South Minneapolis, MN 55439 USA European Headquarters: Rimage Eur ope GmbH Hans-Böckler-Straße 7 63128 Dietzenba ch, Germ any CD and.
Rimage 360i Support information For Rimage 360i™ Support, go to: www.rimage.com/Rimage360iSupport North America South America Asia/Pacific Europe Africa Rimage Corporation 7725 Washington Avenue Sou.
Contents Contents Introduction ..................................................................................................................... 1 Requirements .......................................................................................
Rimage 360i ii.
Introduction Introduction This manual provides the information ne eded to operate the Rimage 360i and identify the parts. To set up and install your Rimage 360i, refer to the Rimage 360i Setup and Installation Gui de. Requirements Software requirements The Rimage 360i will operate only with the Rimage 3 60i Software.
Rimage 360i 2 110808_C Label design requirements The Rimage 360i Software includ es a label editor called CD De sig ner ™ , which is installed on your system. You can use CD De signer to design you r label s. If you have another software application that you pref er, you can create a label and save it as an Acrobat ® (.
Identify the parts of the Rimage 360i Identify the parts of the Rimage 360i This section describe s the Rimage 3 60i hardware and its feature s. Front View Front Cove r Input Door Project Status Indic.
Rimage 360i 4 110808_C Rimage 360i Buttons On the right side of the Rimage 360i, there is one but ton. Pause button • Press this button once to pause the Rimage 360i. • Press this button again to return to normal operation. Inside the front cover of the 360i, there are three buttons.
Identify the parts of the Rimage 360i Rimage 360i Project St atus Indicator (PSI) On the front of the Rimage 360i is the Project Status Indicator (PSI), made up of 5 LEDs. LED: Light-emitting diode. A type of diode that emits light when current passes throu gh it.
Rimage 360i 6 110808_C Rear view Power Po Filter Rear Sw it ch wer Cord Port Cover Cove r USB 2.0 Port.
Operate the Rimage 360i Operate the Rimage 360i This section provides the information that y ou need to prod uce CDs or DVDs with the Rima ge 360i. Powering on the Rimage 360i 1. To power on the 360i, press the power switch on the rear of the 360i. The Rimage 360i initializes.
Rimage 360i 8 110808_C Loading the discs 1. Open the input door. 2. Place up to 25 discs in the disc input with the printable side facing out. 3. Close the input door.
Operate the Rimage 360i Select your printing preferences Printing Preferences allows you to set up and run your Rimage 3 60i to produce the best possibl e label on your discs. # Tip: For additional information about these features, access the online help in Printing Preferences.
Rimage 360i 10 110808_C Setting the print quality Use this procedure to change the print q uality for your images, if necessary. 1. Navigate to Printing Preferences (refer to page 9 ). 2. Select the Disc/Quality tab. 3. In the Disc Options panel, select the appropriate Ty pe from the drop-down list.
Operate the Rimage 360i Adjusting the ink volume used This functionality allows you to adjust the amount of ink that is u sed. 1. Navigate to Printing Preferences (refer to page 9 ). 2. Select the Basic s tab. 3. Select Advanced Features . The Advan ced Features wind ow open s.
Rimage 360i 12 110808_C # Tip If you print on areas of the disc where the surface is not suitable for printing, the ink can smear or run. Changing or enabling masking This functionality allows you to adj ust the non-printable are a, or mask, settings for standard CD/DVD 120 mm media.
Operate the Rimage 360i # Tip: The image below shows a disc with no stacking ring. # Tip: Rimage recommends that you set the inner diameter so that it is 1 mm greater than the actual measurement to prevent the ink from smearing. The inner diameter on Rimage media is 23 mm.
Rimage 360i 14 110808_C Centering the image on the disc The Rimage 360i provides two ways to cente r the image on the disc. You can use the Auto Centering method or the Manual Centering method. The Auto Centering m ethod is accurate to within +/- 0.5 mm.
Maintain the Rimage 360i Maintain the Rimage 360i The procedures in this section will help keep your Rimage 360i in optimum opera ting con dition. General Cleaning # Tip: To keep your Rimage 360i clean, keep it in a dust free environment. Cleaning the exterior If your Rimage 360i becomes dusty: 1.
Rimage 360i 16 110808_C Replace Consumables Replacing the fan filter The fan filter is a consumable item. You will need to change the fan filter after 20 ink cartri dges. Use this procedure to change the fan filter. 1. On the rear of the Rimage 360i, pre s s the tab on the filter cover and lift up the filter cover.
Maintain the Rimage 360i Replacing the ink cartridges Use this procedure to change the in k cartridges on your Rim age 360i. - Important! You must u se t he appropriate ink cartri dges in one of the configurations as stated on page 1 of this document .
Rimage 360i 18 110808_C Learn More Rimage 360i Specifications Standard System One disc recorder, Rimag e 360i with Rimage 360i Di sc Color Printer, and software. Software requirements Rimage 360i Software Input bin capacity 25 Discs Output capacity 25 Discs Physical size Width – 15.
Learn More Technical support and product updates Support for the Rimage 360i is available through your authorized reseller. - Important! Register your Rimag e 360i online or complete and return the registration ca rd so Rimage can notify you of upgrade s as they become available.
Rimage 360i 20 110808_C Safety testing Product name: Rimage 360i Model: RAS17 Notice for USA Tested to Comply with FCC Standards FO R HOME OR OFFICE USE. NOTE: This equipment has been tested and f ound to comply with the limits for a Class B digital device, pursuant to Part 15 of the F CC Rules.
Learn More Rimage 360i Limited 1 Year Warranty Rimage warrants, to the original end user onl y, that all non-consumable par ts of the Rimage 360i Autoloader products will be free from defects in mater.
Een belangrijk punt na aankoop van elk apparaat Rimage 360i (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Rimage 360i heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Rimage 360i vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Rimage 360i leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Rimage 360i krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Rimage 360i bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Rimage 360i kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Rimage 360i . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.