Gebruiksaanwijzing /service van het product RMC40 van de fabrikant RuggedCom
Ga naar pagina of 16
Rugg ed Rugg ed Rugg ed Rugg ed MC MC MC MC RM C40 RM C40 RM C40 RM C40 Installation Guide RuggedCom Inc. 30 Whitmore Road Woodbridge, On tario Canada L4L 7Z4 Web: http://www.
2 2006 RuggedCom Inc. All rights re served Rev101 Federal Communications Commission Radio Frequency Interfe rence Statement This equipmen t has been tested and found to comply w ith the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules.
3 2006 RuggedCom Inc. All rights re served Rev101 Table of Contents 1 Product Overview .................................................................................................................... 4 1.1 Functional Overview .................
4 2006 RuggedCom Inc. All rights re served Rev101 1 Product Over view 1.1 Functional Overview The Rugged Me diaConverter TM is an industrially hardened fiber optical media converter specifically de signed to operate in harsh environ ments such as tho se found in electric utility substations an d factory floors.
5 2006 RuggedCom Inc. All rights re served Rev101 1.3 RuggedMC TM Front Panel Description Fig. 1.3.1 Rugged MC TM Front Panel Detail (Dual LC Style 100BaseFX fiber optic conn ector shown) ITEM Act.
6 2006 RuggedCom Inc. All rights re served Rev101 1.4 RuggedMC TM Side and Bottom View Fig. 1.4.1 Rugged MC TM Side and Botto m View.
7 2006 RuggedCom Inc. All rights re served Rev101 2 Inst allati on 2.1 DIN Rail Mounting Fig. 2.1.1 Rugged MC TM DIN Rail Mounting.
8 2006 RuggedCom Inc. All rights re served Rev101 2.2 Panel Mounting With the use of an optional panel-mount adapt er, the RuggeMC TM series of media converte rs can be panel mounte d. The drawing shown in Figure 2.2.1 shows an example of an RMC unit panel mounted u sing the optional panel mount ada pter.
9 2006 RuggedCom Inc. All rights re served Rev101 2.3 Power Supply Wiring and Ground i ng Fig. 2.2.1 Rugged MC TM Power Supply Inpu ts The Rugged MC TM power supply inputs are identical and a re connected as follows: 1.
10 2006 RuggedCom Inc. All rights re served Rev101 2.4 RJ45 Ports – Signal Description The RJ45 po rt accepts standard category 5 un shielded twisted pair (UTP), or screene d twisted pair (STP) cable with RJ45 male connectors. Fig. 2.3.1 shows th e RJ45 port pin configuration .
11 2006 RuggedCom Inc. All rights re served Rev101 3 Specifica tions 3.1 Power Supply Specifications Power Su pply Type Minimum Input Maximum Input Fuse Rating Maximum P ower Consumption 24 VDC 18 VDC 36 VDC 3.15A(T) 2 48 VDC 36 VDC 72 VDC 3.15A(T) 2 HI (88/300 VDC) 1 HI (120/240 VA C) 1 88 VDC 85 VAC 300 VDC 264 VAC 3.
12 2006 RuggedCom Inc. All rights re served Rev101 3.3 Fiber Optical Port Specifications Speed Standard Mode / Connect or Tx λ λ λ λ (nm) Cable Type 2 ( µ µ µ µ m) Tx Pwr (dBm p eak) 3 (Min / M ax) Rx Sensitivity (dBm Averag e) 3 Rx Saturation (dBm Peak) 3 Typical Distance (km) 1 Power Budget (dB) 100BaseFX MM / ST 1310 50/125 -15.
13 2006 RuggedCom Inc. All rights re served Rev101 3.5 Operational Specifications Parameter Specification Notes Conversion Type Cut-Through High-speed, non -blocking Mac Addre ss Table Length 2048.
14 2006 RuggedCom Inc. All rights re served Rev101 3.6 Mechanical Specifications Parameter Value Comments Dimensions 4.30 x 2.40 x 3.30 inches (110) x (61) x (84) mm (Length x Width x Height) Weight 1.
15 2006 RuggedCom Inc. All rights re served Rev101 4 T ype T est Specificati ons Electrical Sa fety Levels Comments Dielectric Withstan d 2 kV rms for 1 minu te ANSI/IEEE C37.
16 2006 RuggedCom Inc. All rights re served Rev101 4.1 Operating Environment Parameter Ra nge Comments Ambient Ope rating Temperatu re -40 to 85 ° C Ambient Tempe rature as measured from a 30cm radiu s surrounding the center of the Rugged MC TM enclosure.
Een belangrijk punt na aankoop van elk apparaat RuggedCom RMC40 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen RuggedCom RMC40 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens RuggedCom RMC40 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding RuggedCom RMC40 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over RuggedCom RMC40 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van RuggedCom RMC40 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de RuggedCom RMC40 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met RuggedCom RMC40 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.