Rugg edSwitch Rugg edSwitch Rugg edSwitch Rugg edSwitch RS50 0 RS50 0 RS50 0 RS50 0 Installation Guide Installation Guide Installation Guide Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, On tario Canada L4L 7Z4 Web: www.
2 2008 Rugge dCom Inc. All rights r eserved Rev101 Federal Communications Commission Radio Frequency Interfe rence Statement This equipmen t has been tested and found to comply w ith the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules.
3 2008 Rugge dCom Inc. All rights r eserved Rev101 Table of Contents 1 Product Overview ..................................................................................................................... 4 1.1 Functional O verview ..............
4 2008 Rugge dCom Inc. All rights r eserved Rev101 1 Product Ov erview 1.1 Functional Overview The RuggedSw itch RS500 is a substation harde ned, fiber optical Ethe rnet switch specifically designed to ope rate in harsh environments such as those found in ele ctric utility substations and harsh industria l environments.
5 2008 Rugge dCom Inc. All rights r eserved Rev101 1.3 RS500 Front Panel Description Fig. 1.3.1 RS500 Fro nt Panel Detail ITEM Activity Comments Solid Link Established LINK LED (Yello w) Blinking .
6 2008 Rugge dCom Inc. All rights r eserved Rev101 1.4 RS500 Top and Bottom View Fig. 1.4.1 RS500 To p and Bottom View Surge Ground DC(+) DC(-) Safety Ground Stud Failsa fe Output Relay Botto m Vi.
7 2008 Rugge dCom Inc. All rights r eserved Rev101 2 Installation 2.1 DIN Rail Mounting Fig. 2.1.1 RS500 Ra il Mounting DIN RAI L DIN R AIL Mounting Latch Screw Driver Release Action Release Slot .
8 2008 Rugge dCom Inc. All rights r eserved Rev101 2.2 Power Supply Wiring and Grounding Fig. 2.2.1 RS500 P ower Supply Inputs The power supp ly input is connected as follows: 1. + = DC (+) is connect ed to the positive (+) termina l if the power source is DC or to the (Hot) terminal if t he power source is AC.
9 2008 Rugge dCom Inc. All rights r eserved Rev101 2.2.1 Powe r Supply - DC Input Fig. 2.2.2 Powe r Supply – DC Input Note: Ground bus can either be connected to the G round Stud on the rear of the RS50 0 chassis, or the Surge G round port on the screw-in termina l block.
10 2008 Rugge dCom Inc. All rights r eserved Rev101 2.3 HIPOT (Dielectric Strength) Testing HIPOT Dielectric st rength testing cannot be performed in the fie ld due to transient/surge suppression circu itry connected to the RS50 0 Surge/Chassis Ground.
11 2008 Rugge dCom Inc. All rights r eserved Rev101 2.4 Failsafe Output Wiring and Specifications The “Failsafe” outpu t relay is provided to signal critical e rror conditions that may occur on the RS500. The conta cts are energized upon power up o f the unit and remain energized until a critical error occurs.
12 2008 Rugge dCom Inc. All rights r eserved Rev101 3 T echnic al Specification s 3.1 Power Supply Specifications Power Su pply Type Minimum Input Maximum Input Fuse Rating Maximum P ower Consumption 24 VDC 18 VDC 36 VDC 5A(F) 48 VDC 36 VDC 59 VDC 3.
13 2008 Rugge dCom Inc. All rights r eserved Rev101 3.4 Fiber Optical Specifications Parameter Ports 1 to 4 10Mbps Por ts Uplink 100Mbps Port Multi-Mode Single-Mode* Multi-Mode Single-Mode* Speed .
14 2008 Rugge dCom Inc. All rights r eserved Rev101 3.6 Type Test Specifications Electrical Sa fety Levels Comments Dielectric Withstan d 2 kV rms for 1 minu te ANSI/IEEE C37.
15 2008 Rugge dCom Inc. All rights r eserved Rev101 3.7 Operating Environment Parameter Range Comments Ambient Ope rating Temperatu re -40 to 85 ° C Ambient Temperature a s measured from a 30cm radius surround ing the center of the R500 enclosure.
16 2008 Rugge dCom Inc. All rights r eserved Rev101 3.9 Agency Approvals Agency Standards Comments cCSAus, CE CSA C22.2 No . 60950, UL 60950, EN 60950 EN 61000-6 -2 Approv ed FCC FCC Part 15, Class A Approved 4 W arranty RuggedCom wa rrants this product for a period of five (5) years from date of purchase.
Een belangrijk punt na aankoop van elk apparaat RuggedCom RS500 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen RuggedCom RS500 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens RuggedCom RS500 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding RuggedCom RS500 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over RuggedCom RS500 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van RuggedCom RS500 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de RuggedCom RS500 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met RuggedCom RS500 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.