RuggedCom Inc. I 30 W hitmore Road, W oodbr idge, Ontario, C anada L4L 7Z4 Tel: (905) 856-528 8 I Fax: (905) 8 56-1995 I Toll Free: (888) 264-0006 Rugg edSwitch Rugg edSwitch Rugg edSwitch Rugg edSwitch RS9 00G RS9 00G RS9 00G RS9 00G 10-Port M anaged Eth ernet Switc h with Gigabi t Upli nk Ports Installatio n Guide www.
2 2008 Rugge dCom Inc . All rights reserv ed Rev104 Federal Communications Commission Radio Frequency Interference Statement This equipmen t has been tested and found to comply with the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules.
3 2008 Rugge dCom Inc . All rights reserv ed Rev104 Table of Contents 1 Product Overview .....................................................................................................................4 1.1 RS900G Family Fr ont Panel D escription .
4 2008 Rugge dCom Inc . All rights reserv ed Rev104 1 Product Overview The RuggedSwitch ™ RS900G is an industriall y hardened, fully managed Ethernet switch providing dua l fiber optic al Gigabit Ethernet ports a nd eight Fast Ethernet co pper ports.
5 2008 Rugge dCom Inc . All rights reserv ed Rev104 1.1 RS900G Family Front Panel Description Figure 1.1.1 RS9 00G Front Panel View ITEM Activity Comments Solid Link Established LINK LED (Yello w).
6 2008 Rugge dCom Inc . All rights reserv ed Rev104 1.2 RS900G Family Bottom View Figure 1.2.1 RS9 00G Family Bottom View.
7 2008 Rugge dCom Inc . All rights reserv ed Rev104 2 Inst allation 2.1 DIN Rail Mounting An optional DIN ra il mounting bracket is available for the RS90 0G.
8 2008 Rugge dCom Inc . All rights reserv ed Rev104 2.2 Power Supply Wiring and Ground ing 2.2.1 HI Pow er Suppl y Wiring an d Ground ing Figure 2.2.1 RS9 00G Family Power Supply Inputs The RS900G fa mily HI power supply inputs are identical and are connected as follows: 1.
9 2008 Rugge dCom Inc . All rights reserv ed Rev104 2.2.2 DC Pow er Suppl y Wiring and Gro unding Figure 2.2.2.1 DC Power supply wiring and grounding d iagram The RS900 low voltage DC power supply features reve rse polarity protection and dual indepen dent inputs.
10 2008 Rugge dCom Inc . All rights reserv ed Rev104 2.3 HIPOT (Dielectric Strength) Testing Units which a re to be “HIPOT” tested in the field must have the braided g round cable disconnected (see Figure 2.
11 2008 Rugge dCom Inc . All rights reserv ed Rev104 2.4 Failsafe Output Wiring and Specific ations The “Failsafe” outpu t relay is provided to signal critical error co nditions that may occur on the RS900G series switch.
12 2008 Rugge dCom Inc . All rights reserv ed Rev104 2.5 RS232 Port Wiring The RS232 po rt is used for configuring the unit. A stra ight-through serial cable with a DB-9 connector is re quired. There is no need to crossover the Transmit and Receive signals f rom the PC side since this has been done internally as shown in the figu re below.
13 2008 Rugge dCom Inc . All rights reserv ed Rev104 2.6 RJ45 Ports – Signal Description The RS900G se ries switches have several 10/100BaseTX ports that allow connection to standa rd CAT-5 UTP cab le with RJ45 male connectors.
14 2008 Rugge dCom Inc . All rights reserv ed Rev104 3 T echnical Speci fications 3.1 Operating Environment Parameter Range Comments Ambient Operat ing Temperatu re -40 to 85 ° C Ambient Temp erature as measured f rom a 30cm ra dius surrounding the center of th e RS900G enclo sure.
15 2008 Rugge dCom Inc . All rights reserv ed Rev104 3.4 Twisted Pair Data Port Specifications Data Port Media Distance Connect or Type 10/100 Mbp s Cat 5 UTP or STP 100m RJ45 3.5 Fiber Optical Port Specifications For maximum flexibility Ru ggedCom Inc.
16 2008 Rugge dCom Inc . All rights reserv ed Rev104 3.6 Physical Dimensions Parameter Value Commen ts Dimensions 7,4 x 2,6 x 5,0 inches (187,96) x (66,04) x (1 27,0) mm (Length x Width x Depth) Weight 2.
17 2008 Rugge dCom Inc . All rights reserv ed Rev104 3.7 Agency Approvals Agency Standards Commen ts CSA CS A C22.2 No . 60950, UL 6 0950 Approved CE EN 60950, EN 61000-6-2 CE Compliance is claime.
Een belangrijk punt na aankoop van elk apparaat RuggedCom RS900G (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen RuggedCom RS900G heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens RuggedCom RS900G vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding RuggedCom RS900G leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over RuggedCom RS900G krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van RuggedCom RS900G bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de RuggedCom RS900G kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met RuggedCom RS900G . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.