Gebruiksaanwijzing /service van het product AP14236 van de fabrikant Ruud
Ga naar pagina of 36
VA CATION VE RY HOT WA RM A B C COOLER HOTTER VA CATION VE RY HOT WA RM A B C COOLER HOTTER AP14236 (05/07) ! FOR YOUR SAFETY! — Do not store or use gasoline or other flamm able vapors or liquids or other com bu st ib le ma te ria ls in the vicinity of this or any other appliance.
Care and Cleaning Draining ................ 27 Maintenance ............. 27 V ent System Inspection .... 28 Burner Inspection ........ 28 Extended Shut-Down ...... 29 Safety Information Safety Precautions ....... 3–6 LP Gas Models ........... 5 Installation Instructions Location .
Be sur e to read and understand the entire Use and Care Manual before attempting to install or operate this water hea te r . It may sa ve yo u tim e and mone y . Pay par ti cul ar at ten tion to the Saf et y Ins tru ct ion s. Fail ur e to foll ow th es e warnings could result in serious bodily injury or death.
Time/T emperature Relationship in Scalds W ater T em peratu re T ime T o Produce a Serious Burn 120°F More than 5 minutes 125°F 1 1 / 2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 1.
5 LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier .
6 IMPOR T ANT SAFETY INFORMA TION. R E A D A L L I N S T R U C T I O N S B E F O R E U S I N G . ! W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent pr operty damage, personal injury , or loss of life.
Combustion Air Inlet Openings Installing the water heater . This water heater must be installed in accordance with these instructions, local codes, utility company requir ements, and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code.
8 Installing the water heater . Combustion and V entilation Air V entilation (ambient) air temperature must be 100°F or less. Proper operation of the water heater requir es air for combustion and ventilation. Provisions for combustion and ventilation air must comply with refer enced codes and standards.
9 Thermal Expansion Determine if a check valve exists in the inlet water line. Check with your local water utility company . It may have been installed in the cold water line as a separate back flow preventer , or it may be part of a pressure reducing valve, water meter or water softener .
10 Installing the water heater . A new combinati on tempera tur e and pre ssur e r elief valve, complyi ng with the Standard for Relief V alves and Automatic Gas Shut-Off Devices for Hot W ater Supply Systems, ANSI Z21.22, is supplied and must r emain in the opening provided and marked for the purpose on the water heater .
W ARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could r esult in hazardous operating conditions. Leak T esting The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation.
12 Installing the water heater . The water heater must be installed with the factory supplied blower assembly in place. V enting The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing vent or chimney - it must be vented separately from all other appliances.
13 Maximum and Minimum V ent Lengths for Residential 40 & 50 Gallon Power V ents ONL Y NOTICE: The mixing of 2" and 3" vent pipe is not recommended. If 3" pipe is used, a 2" to 3" reducer fitting is recommended at the rubber coupling.
14 Installing the water heater . Number of 90° elbows with V ent Number of 45° Elbows Maximum V ent Pipe Length in Feet (ft) 0’ - 2,000’ Maximum V ent Pipe Length in Feet (ft) 2,001’ and above. See Maximum Altitude chart on left. One (1) None 45 35 One (1) One (1) 42.
15 Additional Considerations Do Not install vent terminal under any patio or deck. T o help prevent moisture from freezing on walls and under eaves, do not locate vent terminal on the side of a build ing with prevailing winter winds.
16 NOTICE: All pipe, fittings, solvent cement, primers and procedur es must conform to American National Standards Institute and American Society for T esting and Materials (ANSI/ASTM) standards.
17 Installing the water heater . All joints in the vent piping must be properly sealed and the following materials are recommended: PVC materials should use ASTM D2564 grade cement. CPVC materials should use ASTM F493 grade cement. ABS materials should use ASTM D2235 grade cement.
18 W iring If local codes permit, the water heater may be connected to electric service with the power cord provided (DO NOT use an extension cord). A grounding receptacle is required.
For increased energy efficiency , some water heaters have been supplied with two 24” sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements.
DO ❑ DO check inlet gas pressure to ensure that it is within the range specified on the rating plate. ❑ DO pr ov id e ade qu at e air for co mb us ti on and ventilation as discussed in the Use and Care Manual and the National Fuel Gas Code. ❑ DO maintain proper clearances to combu stible s as speci fied on the ratin g plate.
Installation Checklist A. W ater Heater Location B. W ater Supply C. Gas Supply D. Relief V alve E. V enting ❑ Close to area of vent. ❑ Indoors and protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed and water heater not installed on carpeted floor .
T ee fitting for vertical hot water supply lines. Hot water supply to house From HOT outlet on water heater Hot water supply to heating unit Supplemental instructions for gas water heaters installed in potable water/space heating applications.
T ypical Piping Diagram f or Combination P otable/Space Heating Installation Spring loaded check valve in heating unit hot water supply line and cold water return line (not supp li ed wi th wa ter h ea te r) NO TE: This check valve is incorporated in some heating units.
Safety Precautions Do turn off manual gas shut-of f valve if water heater has been subjected to over heating, fire, flood, physical damage or if the gas supply fails to shut off. Do Not turn on water heater unless it is completely filled with water . Do Not turn on water heater if cold water supply shut-off valve is closed.
25 Operating the water heater . W ater T emperature Setting… Maximum water temperatures occur just after the burner has shut off. T o determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream.
26 Sequence of Operation… During initial start-up or a call for heat, the control will verify the vacuum switch is open. Once the control verifies the blower vacuum switch is open, the control will energize the blower motor for the pre-purge sequence (approximately 5 seconds).
27 Car e and cleaning of the water heater . Draining the W ater Heater ! CAUTION: Shut off gas to the water heater at the gas control (thermostat) gas cock or manual shut-off valve befor e draining water .
28 Housekeeping V isually inspect the hot surface ignitor . T o ensure sufficient ventilation and combustion air supply , proper clearances must be maintained. When installed in a closet, DO NOT block or obstruct any of the combustion air inlet openings located around the perimeter of the water heater .
29 V acation and Extended Shut-Down If the water heat er is to rema in idle fo r an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas. The water heater and piping should be drained if they might be subjected to freezing temperatures.
30 Befor e Y ou Call For Service… T roubleshooting T ips Save time and money! Review the charts on the following pages first and you may not need to call for service.
31 Problem Possible Causes What T o Do Rumbling noise Scale and sediment Drain the water heater to remove scale and sediment from the tank. Refer to the top of page 26. Relief valve Pressure build up This is an unacceptable condition and must be producing popping caused by thermal corrected.
Gas V alve LED Codes 32 CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
33 Replacement Parts. For 40 and 50 gallon models using natural or LP gas. Instructions For Placing a Parts Order All parts orders should include: The model and serial number of the water heater from the rating plate. Specify type of gas (natural or LP) as marked on the rating plate.
34 Notes:.
35 Notes:.
36 IF YOU NEED SER VICE 1. Should you have any questions about your new water heater, or if it requires adjustment, repair , or routine maintenance, it is suggested that you first contact your installer , plumbing contractor or previously agreed upon service agency .
Een belangrijk punt na aankoop van elk apparaat Ruud AP14236 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Ruud AP14236 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Ruud AP14236 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Ruud AP14236 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Ruud AP14236 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Ruud AP14236 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Ruud AP14236 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Ruud AP14236 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.