Gebruiksaanwijzing /service van het product CMH1822 van de fabrikant Sanyo
Ga naar pagina of 18
SERVICE MANUAL (Basic Information) CMH1822 / KMH0922 ( ✕ 2) SPLIT SYSTEM AIR CONDITIONER 8526481017400 REFERENCE NO. WM – 700700 W Indoor Unit Outdoor Unit CMH1822 KMH0922 92-144 S/M (Basic) 00.
92-144 S/M (Basic) 00.12.13 10:32 AM ページ B.
ii WM – 700700 SER VICE MANUAL CMH1822 / KMH0922 ( × 2) (Basic Information) 92-144 S/M (Basic) 00.12.13 10:32 AM ページ ii.
WM – 700700 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
T able of Contents Page 1. OPERA TING RANGE ............................................................................................................................... 1 2. SPECIFICA TIONS ..........................................................
1 WM – 700700 1. OPERA TING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95°F DB / 71°F WB 115°F DB Minimum 67°F DB / 57°F WB 67°F DB CMH1822 / KMH0922 ( × 2) 92-144 S/M (Basic) 00.
DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering air temperature 80°F DB / 67°F WB Heating: Outside air temperature 47°F DB / 43°F WB Indoor unit entering air temperature 70°F DB Model No.
3 WM – 700700 DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering air temperature 80°F DB / 67°F WB Heating: Outside air temperature 47°F DB / 43°F WB Indoor unit entering air temperature 70°F WB Model No.
WM – 700700 4 3. DIMENSIONAL DA T A Outdoor Unit: CMH1822 Indoor Unit: KMH0922 O.D. 3/8" wide tubing service valve 2-9/32 3-3/4 11-7/32 1-3/16 2-1/4 32-11/16 3/4 24-13/16 Air discharge Air intake Air intake 21-3/16 5-3/4 12-3/12 13-1/4 4 × 15/32 dia.
4. COOLING CAP ACITY 230V CMH1822 / KMH0922 ( × 1) 5 WM – 700700 TC: Total Cooling Capacity (BTU/ H) SHC: Sensible Heat Capacity (BTU/ H) kW: Compressor Input (kW) Remarks: Rating conditions (* mar.
6 WM – 700700 208V CMH1822 / KMH0922 ( × 1) TC: Total Cooling Capacity (BTU/ H) SHC: Sensible Heat Capacity (BTU/ H) kW: Compressor Input (kW) Remarks: Rating conditions (* mark) are: Outside ambie.
7 WM – 700700 5. HEA TING CAP ACITY 1 Phase 60Hz 230V Model Name: CMH1822 / KMH0922 ( × 1) Indoor Entering Air Temperature 70 ° F Temperature of Air Entering Outdoor Coil ( ° F D.B. at 75% RH) Heating Capacity (BTU/h) 30,000 25,000 20,000 15,000 10,000 5,000 23 ( – 5) 32 (0) 41 (5) 50 59 (15) 68 (20) 75 ° F (23.
8 WM – 700700 1 Phase 60Hz 208V Model Name: CMH1822 / KMH0922 ( × 1) Indoor Entering Air Temperature 70 ° F Temperature of Air Entering Outdoor Coil ( ° F D.B. at 75% RH) Heating Capacity (BTU/h) 30,000 25,000 20,000 15,000 10,000 5,000 23 ( – 5) 32 (0) 41 (5) 50 59 (15) 68 (20) 75 ° F (23.
Heat exchanger Narrow tube O. D. 1/4" (6.35mm) Wide tube O.D. 3/8" (9.52mm) Service valve Muffler Accumulator Compressor A Reversing valve Service valve Dehydrator Capillary tube ( ) Check valve Strainer Heat exchanger Narrow tube O.D. 1/4" (6.
10 WM – 700700 7. ELECTRICAL DA T A ● Electrical Characteristics CMH1822 / KMH0922 ( × 1) Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering.
11 WM – 700700 ● Electrical Wiring Diagram Outdoor Unit: CMH1822 CMA S C R BLK RED Compressor motor A PTC. A WHT BLK WHT OLR. A CMB R C S RED Compressor motor B WHT OLR. B BLK WHT BLK PTC. B BLK 1 2 7 6 5 4 3 2 1 3 4 12 3 4 12 1 2 1 2 CONTROLLER S.
12 WM – 700700 Indoor Unit: KMH0922 1 1 2 1 2 1 1 12 12 2 2 5 5 4 4 3 3 1 1 5 5 4 4 3 3 1 1 2 2 6 6 Thermistor 2P Supply CONTROLLER Remote control switch Fan motor FM 2 3 1 2 1 2 BRN PNK GRY YEL WHT.
For parts or service contact SFS Corporation: 1200 West Artesia Blvd., Compton, California 90220 Printed in U.S.A. CORPORATION 1991/Nov./12M SANYO Canada Inc.: Toronto, Ont. M4H 1M6 In Canada WM – 700700 H407/12M Printed in U.S.A. 92-144 S/M (Basic) 00.
Een belangrijk punt na aankoop van elk apparaat Sanyo CMH1822 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sanyo CMH1822 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sanyo CMH1822 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sanyo CMH1822 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sanyo CMH1822 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sanyo CMH1822 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sanyo CMH1822 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sanyo CMH1822 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.