Gebruiksaanwijzing /service van het product CVW-EXA284 van de fabrikant Sanyo
Ga naar pagina of 30
CVW-EXA284 / CVW-EXA224 (H: 84 7/8”, L: 96 3/8”) / (H: 84 7/8”, L: 144 5/8”) MULTI-DECK FRESH PRODUCE CASES INSTALLATION & SERVICE MANUAL REMOTE TYPE DISPLAY CASE 2010 CVW-EXA184 / CVW-EXA.
2 Activity Safety Precautions In order to prevent any i njuries to person, equi pment and/or damage to the SANYO Cases, sections requi ring additi onal care to be undertaken will hav e one or all of t.
3 T ABLE OF C ONTENTS 1 SPECIFICAT IONS .................................................................................................................................................. 5 1.1 CVW-EXA284 / CVW-EXA224 ..................................
4 6 CARE AND CLEANING GUIDELINES ................................................................................................... .......... 21 6.1 E XTERIOR P ANELS (D AILY C LEANING ) ..............................................................
5 1 Specifications 1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”) Model Name CVW-EXA284 CVW-EXA224 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce) Cooling Capacity: 1224 BTU/h/ft.
6 1.2 CVW-EXA184 (H: 80 7/8”, L: 96 3/8”) / CVW-EXA124 (H: 80 7/8”, L: 144 5/8”) Model Name CVW-EXA184 CVW-EXA124 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh produce) Cooling Capacity: 1146 BTU/h/ft. ( 2682W ) 1146 BTU/h/ft.
2 Dimensions 2.1 External Dimensions 2.2 Footprint ① Waste Outlet ② Electrical Connection ③ Refrigeration Outlet * Dimensions given in inches and millimeters (mm in parentheses).
2.3 External Dimensions 2.4 Footprint * Dimensions given in inches and millimeters (mm in parentheses). CVW-EXA184 / CVW-EXA124 ① W a s t e O u t l e t ② E l e c t r i c a l C o n n e c t i o n .
9 3 Unloading and Carpentry P rocedures 3.1 NSF Certification The SANYO Cases described in this manual are built to meet the requirements of American Nation al Standard/NSF International Standard 7.
10 3.5 Aligning Cases WARNING SANYO Cases are heavy and bulky, an d require at least two people for unloading, mov ing, and inst allation. Do not walk on the top of the SANYO Case s. Walking on the top of the SANYO Case may lead to serious injury and/or damage to the SANYO Case.
11 3.7 Joining Instructions 3.7.1 Applying gasket (for connecting cases or installing side panels). ① Make sure that all SANYO Cases are resting level. ② Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.
12 3.7.2 Connecting cases. ① Apply gasket as described above. ② Connect cases by using the attached bolts, joint covers, and nuts. Silicone seal Note: Gasket ends that are open must be sealed off by applying silicone at the installation site. Note: Connection point must be silicone sealed.
13 3.8 Installing Patch Ends 1. Apply gasket to case body (per previo us inst ructions). 2. If present, remove protective film from inside wall of Patch End. 3. Place Patch End to line up with bolt holes. 4. From inside unit ratchet in M8 & op tional M5 bolt into Patch End until secure.
14 3.9 Installing Kickplate 1. Align the mounting hole in the Kickplate with the sl ot in the Kickplate Mounting Bracket on the SANYO Case and tighten accordingly.
15 3.10 Installing Handrail and Bumper Attaching the Bumper 1. Attach Maintenance Bumper (length 39-3/8 inches ) to Bumper Brackets over the electrical connection box (“Raceway”) on each SANYO Case. Th e Raceway is located on the right end of each SANYO Case.
16 4 R efrigeration, Plumbing & Electrical P rocedures 4.1 Piping (Plumbing, Refrigeration) ● U-trap installation Install U-trap referring to the drawing below.
17 4.2 Electrical Data Please refer to Specifications sectio n and nameplate attached to merchand iser for electrical information. 4.3 Electrical – Guidelines & Precautions All wiring and electrical field wo rk must comply with the National Electrical Co de (“NEC”) and other applicable local codes.
18 4.4.2 Wiring Diagram CVW-EXA284/184 C VW-EXA224 / 124.
19 5 Operation 5.1 Load Limits In order to maintain proper temperatur e and unit performance, the Dual Air Curt ains in each SANYO Case must remain unobstructed: Do not stock shelves beyond the marked load limits. Do not block Honeycombs or Return Air Grilles.
20 Installing FDA/NSF Thermometer Suggested locations for the thermometer re quired by NSF/ANSI 7 and the FDA Food Code are indicated above. It is the respon sibility of the Purchaser/End User of the SANYO Case to determine the location wi th in the food storage area that best meets these code requirements.
21 6 Care and Cleaning Guidelines In order to keep SANYO Cases sanitary and in good working order, we recommend thorough periodic cleaning as follows: 6.1 Exterior Panels (Daily Cleaning) a. Exterior panels should be cleaned wi th water only. Wet a soft cloth and wring it out to wip e down panels.
22 Please make sure to check and clean the drain trap at least once a month. Remove any material that has gathered in the drain trap and dispose of it.
23 7 Service 7.1 Replacing Fan Motors and Blades HAND PROTECTION REQUIRED! Activities to be undertaken require finger and palm protection to prevent personal injuries. To replace the fan motors: ① Remove the outer Air Curtain Duct Cover and socket covers.
24 For models with Standard-type (AC) Fan Motors: CVW-EXA124/224 CVW-EXA184/284 No. Part Name Model Part Number Quantity Quantity Hex Nut - HN44162520U18 5 3 Spring Washer - SW49266225U18 5 3 ① -a .
25 For models with high-efficiency-type (DC) fan motors: CVW-EXA124/224 CVW-EXA184/284 No. Part Name Model Part Number Quantity Quantity Hex Nut - HN44162520U18 5 3 Spring Washer - SW49266225U18 5 3 .
26 7.2 Replacing Electronic Ballasts CVW-EXA124/224 CVW-EXA184/284 Type Model Part Number Quantity used Quantity used 3-lamp QHE3X32T8/UNV ISN-SC-1-CC-B 8FC05400000301 2 - 2-lamp QHE2X32T8/UNV ISN-SC-.
27 7.3 Replacing Fluorescent Lamps The unit comes with covers placed over each fluorescent lamp. Ensure that these covers are placed over the new lamps before reinstallation. LAMP END CAP CAUTION! Always use Sanyo lamp covers and end caps wh en replacing lamp covers and end caps.
28 7.3 Expansion Valve D a n f o s s MODEL Valve Body P.N. Body Type Refrig erant Valve Orifice P.N. Orifice Type 9FT2450000110 TUAE 068U2287 R404A 9FT2450000100 TU7 068U1037 CVW-EXA124 CVW-EXA224 9FT.
29.
SANYO E & E Corporation 2001 Sanyo Avenue, San Diego, CA 92154-6229 USA Toll Free USA 800-95-SANYO (72696) · Fax 619-661-4183 http://us.sanyo.com/Food-Solutions Manufactured and Distributed by: MCVW V01.
Een belangrijk punt na aankoop van elk apparaat Sanyo CVW-EXA284 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sanyo CVW-EXA284 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sanyo CVW-EXA284 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sanyo CVW-EXA284 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sanyo CVW-EXA284 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sanyo CVW-EXA284 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sanyo CVW-EXA284 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sanyo CVW-EXA284 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.