www.schneider-electric.com Siemens AG SIMATIC S7 Ethernet 04/2010.
2.
3 Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About the Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 1 SIMATIC S7 Ethernet . . . . . . . . . . . . . . . . . . . . .
4.
5 § Safety Information Important Information NOTICE Read these instru ctions carefully, and look at the equipment to become familiar with the device before trying to install, operat e, or maintain it.
6 PLEASE NOTE Electrical equipment should be installed, o perated, serviced, and maintained only by qualified personnel. No re sponsibility is assumed by Schnei der Electric for any consequences arising out of the use of this material .
7 About the Book At a Glance Document Scope This manual describes the device driver commu nication settings in the Vijeo- Designer screen editing software. Vijeo-De signer enables you to design Magelis target machines that communicate with PLCs, drives, field devices, and oth er equipment.
8 Product Related Infor mation * For additional information, refer to NEMA ICS 1.1 (latest edition) , “Safety Guidelines for the Application, Installa tion, and Maintenance of Solid State Control.“ User Comments We welcome your comments about this do cument.
9 1 SIMATIC S7 Ethernet SIMATIC S7 Ethernet Subject of this Chapter This chapter explains the SIMATIC S7 Ethernet. What's in this Chapter? This chapter contains the following topics: Topic Page S.
SIMATIC S7 Ethernet 10 System Structure Overview The following table describes the basic system setup fo r connecting the target machine to Siemens S7-200/300/400 Series PLCs over a netwo rk.
SIMATIC S7 Ethernet 11 *2 PLC supports a maximum of 64 conn ections. Because 2 conn ecti ons are required for each target machine, one for Fetch and one for Write, the PLC can support up to 32 target machines. *3 The direct connection to the Ethern et Interface on th ese CP Us only supports the “OP Communication” type.
SIMATIC S7 Ethernet 12 Supported Device Addresses Overview The following tables list the device addre ss ranges you can enter from the Device Address keypad. For actual device address range s supported by the PLC, refer to the corresponding PLC manual.
SIMATIC S7 Ethernet 13 *6 Data blocks are created by the user. Available a ddresses depend on what the user has created. *7 PLC word addresses defined for integer, float, and string variab les mu st be even-numbered. i.e., IW5 is not a valid device address for an integer variable.
SIMATIC S7 Ethernet 14 *7 PLC word addresses defined for integer, float, and string variabl es must be even-numbered. i.e., IW 5 is not a valid device address for an integer variable. Must be either IW4 or IW6. *8 16-bit and 32-bit data , High and Low, refer to data as defi ned in the following example s.
SIMATIC S7 Ethernet 15 Consecutive Equipment Add resses Overview The following table lists the maximum number of consecutive addresses that can be read by each PLC. Refer to this table w hen using block transfers. Note : z To speed up data communicatio n, use consecutive variable addresses on the same panel screen.
SIMATIC S7 Ethernet 16 I/O Manager Configuration Overview The driver and equipment, which enab le communication between the target machine and the PLC, depends on the PLC type. Screen example of I/O Manager Configuration Note : z For informatio n on how to display the [New Driver] dialog box, see the online help.
SIMATIC S7 Ethernet 17 Equipment Configuration Overview To set up details about the communicati on process between the target machine and the PLC, use the [Equipment Configuration ] di alog box. For an overview of the driver and equipment settings, see Equ ipment Configuration .
SIMATIC S7 Ethernet 18 Fetch/Write Screen Description Area Description IP Address Enter the PLC unit’s IP address. PLC Ports Fetch Specify the PLC’s TCP port number for the Fetch operation. Specify values between 1024~65535. Write Specify the PLC’s TCP port number for the Write operation.
SIMATIC S7 Ethernet 19 S7-300/400 Series Screen De scription Note : z The IP Address and PLC Ports field s s hould match the communication settings on the PLC unit. z The connection configuration on the PLC can be configured t o accept onl y specified host IP addresses and specifie d host ports.
SIMATIC S7 Ethernet 20 Device Address Configuration Overview To set up a PLC variabl e in the Variable List, use the Device Address Keypad from the variable properties.
SIMATIC S7 Ethernet 21 Screen De scription Area Description Memory Area Lists the device type. Data Block D efines a number for a valid dat a block. This field is available when DB is selected as theMemory Area. To enter a valid data block, click the Data Block field’s ellipsis to display the[Data Block Selector] keypad.
SIMATIC S7 Ethernet 22.
Een belangrijk punt na aankoop van elk apparaat Schneider Electric S7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Schneider Electric S7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Schneider Electric S7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Schneider Electric S7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Schneider Electric S7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Schneider Electric S7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Schneider Electric S7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Schneider Electric S7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.