OWNER’S MANUAL Model: PST -1000 Carbon Pile Charging System Analyzer For 6 and 12 V olt Batteries 00-99-000443/1004 Questions? Call Customer Service 1-800-621-5485 Send Warranty Product Repairs To: Customer Returns P.O. Box 280 1025 E. Thompson Avenue Hoopeston, IL 60942-0280 ELECTRIC CORPORA TION MT .
2 PST -1000 IMPORT ANT OPERA TING & SAFETY NOTES READ BEFORE PROCEEDING WITH TESTS 1. Always work in a well ventilated area. Never start a vehicle’ s engine in an enclosed area. 2. Never smoke or allow any other open flame to come within 25 feet of the vehicle being tested.
3 EXTERNAL VOL TS LEADS (1 mg ohms) These leads may be used for measuring any DC voltage on a vehicle when the test selector switch is placed in External posi- tion. The voltmeter circuit is isolated and has an automatic polar- ity indication. T ypical applications are for measuring load volt- ages and cable connection voltage drop s.
4 readings are taken, the battery should be charged five minutes to stimulate mixing. (Refer to battery manufacturer ’s instructions regarding removal of vent caps while charging battery). ELECTROL YTE CAUTION Battery electrolyte is SULFURIC ACID. It can eat holes in clothes and skin.
5 Figure 2 Connections For ST ARTER TEST BA TTERY CHASSIS BLACK RED KEY SWITCH TRANSMISSION SAFETY SWITCH ST ARTER SOLENOID RELA Y + + - DIAGNOSTIC TEST PROCEDURE 1. Engine should be at normal operating temperature. 2. Hook-up the analyzer as described in the general instructions.
6 Figure 3 Connections For INSULA TED-POS CIRCUIT TEST BLACK ST ARTER SOLENOID RELA Y BA TTERY CHASSIS POS + + - 1. Disable ignition (as described earlier) to prevent engine from starting during test. 2. Operate starter and read voltmeter while cranking.
7 AL TERNA TOR SYSTEM TESTS The following test procedures will determine if there is a problem in the diode stator , voltage regulator , electrical load requirements, or in the alternator amperage output. The test s can pinpoint prob- lems to the wires and connection between the charging output terminal, the regulator , the field, and the battery .
8 Causes of high voltage drop s can be from LOOSE OR COR- RODED CONNECTIONS at the output terminal of the alternator , the car ’s ammeter , battery terminal connection on the starter so- lenoid, battery cable connections, faulty wiring from alternator to regulator , to ammeter , to starter solenoid, or between the alter- nator and the engine.
9 Figure 10 BLACK SOLENOID RELA Y BA TTERY CHASSIS RED + + - A B DISCONNECT REGULA TOR JUMPER AL TERNAT OR OUT FIELD STEPS FOR EXTERNAL REGULA TOR (TYPE) AL TERNA- TOR 1. Make connections according to figure 10 above. 2. With ignition key OFF , unplug regulator or disconnect field wire.
10 3. Place the Amp Probe around the starter cable. 4. Connect the external volts positive lead to the positive terminal of the starter . 5. Connect the external volts negative lead to the starter ground. 6. Set the V olts Selector to External V olts ± 199.
11 24 V olt Output The 24 volt TRANSFORMER-RECTIFIER output only charges the CRANKING battery after the starter motor has drawn current from the battery . The following procedure should be used to simu- late a recent starter draw and test for output current.
12 LIMITED W ARRANTY SCHUMACHER ELECTRIC CORPORA TION, 801 BUSINESS CENTER DRIVE, MOUNT PROSPECT , ILLINOIS 60056-2179 MAKES THIS LIMITED W ARRANTY TO THE ORIGINAL PURCHASER A T RET AIL OF THIS PRODUCT .
Een belangrijk punt na aankoop van elk apparaat Schumacher PST-1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Schumacher PST-1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Schumacher PST-1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Schumacher PST-1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Schumacher PST-1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Schumacher PST-1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Schumacher PST-1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Schumacher PST-1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.