Gebruiksaanwijzing /service van het product AFE325 van de fabrikant Scotsman Ice
Ga naar pagina of 23
AFE325 Product Manual Purpose of this manual: To provide detailed installation and operation instructions; to give insights into how the machine works; to list possible causes for problems; and to suggest procedures for specific types of service. The AFE325 is an ice maker that makes and stores flaked ice.
Specifications: . Model Dimensions Basic Electrical Condenser Type Min. Circ. Ampacity Max. Fuse Size Refrigerant Charge (R-134a) AFE325AE-1A 33 x 36 1 ⁄ 16 x 24 115/60/1 Air Cooled 10.7 15 11 oz. AFE325AE-6A 33 x 36 1 ⁄ 16 x 24 230/50/1 Air Cooled 5.
To The Installer: A professional installation of any product is critical to the long term satisfaction of the user. The AFE325 is designed to be installed indoors, near a drain. Determine the location from the anticipated use and any options planned for.
For The Plumber Drains: The ice maker requires a gravity drain for the reservoir overflow and bin drain. T he pit c h on the drain tubes must be at least 1/ 4 inch f all per foot of horizontal run. On long horizont al runs, a vent at the back of t he cabinet will improve draining, and is recommended.
For The Electrician Electrical connections: Follow All Local, State & National Codes Check the nameplate for voltage and current requirements. An electrical cord is not supplied. Connect the AFE325 to a separate electrical circuit. Wiring to the machine must conform to all codes.
Final Check List & Initial Start Up 1. Is the machine located indoors where the temperature limitations are not exceeded? 2. Is there at least 6" clearance on the left side and the back of the cabinet for adequate air flow? 3. Is the water supply adequate, and has a shut off valve been installed? 4.
User Operation The AFE325 is an automatic ice flaked machine. All it requires is cool air, clean water, a drain, and an adequate supply of electrical power. The user must regularly sanitize and clean the machine. Component Location & Function Evaporator.
Component Location: Control Box Auger Delay Pressure Control: This pressure switch, connected to the low side of the refrigeration system, controls the auger drive motor. On-Off switch: This toggle switch shuts off the machine. It is not a complete disconnect.
Refrigeration System Operation The AFE325 uses a forced draft air cooled condenser, capillary tube and hermetic compressor. The system uses R-134a as a refrigerant. High pressure, high temperature refrigerant is forced thru the condenser where it looses enough heat to condense.
Water System Operation: The water system consists of a float valve and reservoir. The water level in the reservoir tank is the same level as that inside the evaporator. Building water supply flows to the float valve and the float valve opens to add water to the reservoir as water flows out to the evaporator.
Mechanical Operation ELECTRICAL SEQUENCE There are two circuits in the AFE325: one is a series circuit with several switches connected in series to the compressor. The other is a parallel branch of the series circuit, controlling the gear drive motor.
Sanitation and Cleaning Mai ntenance : The water and ice makin g syste ms will n eed t o b e period ica lly sanitize d and de-min era lized . Th e air coole d con dens er will also ne ed to be kept clea n. Det aile d ins tru ctio ns are pro vide d on pag e 14.
Maintenance and Cleaning In some areas, the water supply to the ice maker will contain a high concentration of minerals, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year.
Maintenance: Air Cooled Condenser, Bearings 1. Disconnect electrical power. 2. Remove front louvered panel 3. Wipe the lint off the front of the condenser. If needed, clean the interior of the condenser. 4. Use pressurized air to blow the lint from the inside of the condenser.
Maintenance: Component Inspection Auger. The auger is made of stainless steel. It has a polished surface that may be very shinny or dull. Allow the auger to dry, if mineral scale is found on the auger’s surface, clean off the auger with ice machine cleaner and a scrubbing pad.
Service Diagnosis Problem Possible Cause Probable Correction No ice, nothing is operating. Unit has no power. Restore power. If breaker or fuse tripped, check for overloaded circuit or short circuit. Master switch off Switch unit on. Determine why switch was off.
Service Diagnosis PROBLEM POSSIBLE CAUSE PROBABLE CORRECTION Unusual noise Mineral scale in evaporator Clean water system with ice machine cleaner. Auger coupling dry Grease coupling Auger coupling worn Replace coupling and adapter stand. Bearings worn Replace bearings and water seal.
Removal and Replacement Water System The water system consists of the reservoir and inlet water valve. Reservoir. 1. Shut off the water supply. 2. Remove the top panel. 3. Remove the left side panel. 4. Drain the water reservoir and evaporator. 5. Disconnect inlet and outlet tubes from the reservoir.
Water Seal & Bottom Bearing Replacement: 1. Remove old rotating half from the auger. Clean the mounting area. 2. Place a bead of food grade sealant (such as Scotsman part number 19-0529-01) onto the shoulder of the auger where the rotating half of the water seal will be installed.
Refrigeration System This ice machine uses R-134a as the refrigerant. This refrigerant has no chlorine, and therefore requires polyolester type refrigerant oil. This oil requires specific service procedures. Service Recommendations: This ice machine has a sealed refrigeration system.
Gear Reducer Removal 1. Disconnect electrical power. 2. Shut off the water supply. 3. Remove the top, front and side panel. 4. Remove the control box cover. 5. Remove the centrifugal switch cover on the top of the auger drive motor. 6. Disconnect the electrical wires from the centrifugal switch.
Gear Reducer Rebuild 1. After the gear reducer has been removed, the internal components may be inspected and/or replaced. Remove all bolts holding the two case halves together. 2. T ap against the roll pins at each end of the gear cases to split them.
Motor Cover & Top Rotor Bearing Fan Stator Rotor First Gear Shaft Seals, 2 are used per shaft as shown Woodruff Key Spacer Washer, Use To Adjust Height of Gears to Avoid Rubbing Gear Reducer AFE32.
Een belangrijk punt na aankoop van elk apparaat Scotsman Ice AFE325 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Scotsman Ice AFE325 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Scotsman Ice AFE325 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Scotsman Ice AFE325 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Scotsman Ice AFE325 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Scotsman Ice AFE325 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Scotsman Ice AFE325 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Scotsman Ice AFE325 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.