Gebruiksaanwijzing /service van het product LX5000 van de fabrikant AVerMedia Technologies
Ga naar pagina of 60
AVerMedia LX5000 Digital Video Recorder & Remote Surveillance System User’ s Manual 300AAABX / V3.0 / 0 612 AVerMedi a LX5000 Us er’s Manua l 2 FCC NOTICE This device h as been t ested and fo und to comply with the limits for a C lass a digital d evice, pursuant to Part 15 of the FCC Ru les.
AVerMedi a LX5000 Us er’s Manua l 3 DISCLAIMER No warra nty o r repr esentat ion, ei ther exp ress ed or imp lied, is made with resp ect to the c ontents o f this documen tation, its quality, performanc e, merchant ability, or fitness for a parti cular purpose.
AVerMedi a LX5000 Us er’s Manua l 5 6.4 S TA RT R ECORDING .................................................................................... 100 6.5 E XIT R EMOTE M AN AGER .........................................................................
AVerMedi a LX5000 Us er’s Manua l 7 1.2 Package Conte nts AVerMedi a LX5000 • LX500 0: 1/2 x A V erMedia Vid eo Captur e Card • 1 x LA N Car d (RE AL TE K R TL81 39) • 1 x CD (include s LX5000 sof tware, Linux Op erating System, RemoteManager S/W , and User’s Manual) • Optiona l: I/O Box, and I/O Ca ble 1.
AVerMedi a LX5000 Us er’s Manua l 9 Modem List of modem s supp orted: • Lucent Venus Serial V oic e Modem • Rockwell (Connex ant) chipset V oice Modem • T opic chipset V oice Mod em • Zyxel .
AVerMedi a LX5000 Us er’s Manua l 11 2.2 Installing the AVer Media LX5000 Video Cards The follow ing instruc tions are for installing v ideo cards into the AV erMedia LX500 0. Befor e installing the video c ard, turn off the computer ’s power , unplu g the powe r cable a nd disc onnect a ll other cables attached to the back of the computer .
AVerMedi a LX5000 Us er’s Manua l 13 Cameras n eed to be i nstalled accord ing t o the n umerical order displa yed on t he diag rams abov e for each mo de l. Wi th the LX5000 , cameras will be installe d from top to bott om begi nning with t he left- most column.
AVerMedi a LX5000 Us er’s Manua l 15 CONT ACT RATINGS Conta ct Arrang ement 1 Form C ( SPDT) max. Switch P ower max. Switch voltage max. Swit ch curren t 125V A 60W 125V AC 3 0VDC 2A Contact R esist.
AVerMedi a LX5000 Us er’s Manua l 17 Chapter 3 Software Installation 3.1 In stalling Fro m the Soft ware CD This sectio n describes the instr uctions for ins talling the OS and sys tem softwa re from the A Ve rMedia LX50 00 system CD.
AVerMedi a LX5000 Us er’s Manua l 19 Chapter 4 Syst em Configura tion and Operation 4.1 Entering the Sy ste m Befor e you start running LX500 0 system, the s ystem will perfor m a routine har dware check -up and scan all har d disks. In general, the har d disk scan t akes on ly a few s econds.
AVerMedi a LX5000 Us er’s Manua l 21 4.2 System Config uration Main S creen Network S tatus Click this button to show the curr ent network st atus where you can see ev ery cli ent conn ecting to the server . Click 'clear all' to delete the record; click 'save to disk ' to save the record.
AVerMedi a LX5000 Us er’s Manua l 23 the grids will turn yellow on which the f urther infor mation will be shown. With the inform ation go to Sys tem setup Alarm setup Rel ay →→ alarm to find out the generated sensor . Time/ Date This field co ntains the curre nt time (hour:minute:second ) and date (year /month/date).
AVerMedi a LX5000 Us er’s Manua l 25 4-Camer a Displ ay The fir st click of this button disp lays cameras 1 through 4 on the scr een. Continue to clic k to view cameras 5 thro ugh 8, 9 throug h 12, 13 thro ugh 16, and finally returning to ca meras 1 through 4.
AVerMedi a LX5000 Us er’s Manua l 27 4.2.1 System Set up System c onfig uratio n Enter sy stem setti ng screen, user can do the following: s ystem sett ing, change pa ssword, cam era settin g, recor.
AVerMedi a LX5000 Us er’s Manua l 29 2. Date format : System provi de two di fferent date format: yy/mm/ dd(y ear/m onth/ day) a nd mm/d d/yy ( month /day/ ya r) 3. Repe ating sc anning interval: After sele cting the camera, enter the number of seconds for all cameras st aying during repeat scan ning.
AVerMedi a LX5000 Us er’s Manua l 31 K ey in”1 23456” ( defaul t root passwo rd) the on passwo rd field f or the initial log in from roo t. Click OK to bring the next dialog as follow s to change passw ord: In the C hange password field of the root ’s config uring area, type the new password and retype it to confirm the password.
AVerMedi a LX5000 Us er’s Manua l 33 Intellig ent search √ √ √ Change split √ √ √ Printer Setup √ √ √ Backup ◎ ◎ ╳ Save to floppy √ √ √ Show E -Map √ √ √ PTZ Control ◎ ◎ ╳ Star t Network Serv ice ◎ ◎ ╳ Exit ◎ ◎ ◎ √ : No passwor d neede d ◎ : Needs password ╳ : Not authorize 2.
AVerMedi a LX5000 Us er’s Manua l 35 PTZ Control ◎ ◎ ╳ Star t Network Serv ice ◎ ◎ ╳ Exit √ √ √ √ : No passwor d neede d ◎ : Needs password ╳ : Not authorize 3 . Wh e n o n ly t he enable opera tor button is activated, access es to the follow ing configurations are restr icted as follow s.
AVerMedi a LX5000 Us er’s Manua l 37 4. When neither the en ab le a dmin ist rat or no r t he enab le operat or buttons are activated, restrictio ns are as follows.
AVerMedi a LX5000 Us er’s Manua l 39 Click Camera Setu p . It will show a window like the follo wing: You can select the Camera based on the se rial nu mber, a nd do th e prope r adjustment f or each cam era: The adjustment includ es turning off the camera signal , display t he camera, camera name, picture adj ustment, and PTZ camera setting .
AVerMedi a LX5000 Us er’s Manua l 41 6. PTZ camera After you finish PTZ c amera installation, enter manuf acture name, COM port and add ress for P TZ came ra set ting in came ra o ption, and click sa ve butt on to fin alize the s ystem and camera communi cation setting.
AVerMedi a LX5000 Us er’s Manua l 43 Quality Adjust th e recor ding qua lity by dr agging t he scrol l bar . K eep in min d that th e more precise the recording qu ality , th e more space i s taken up on the h ard di sk. High speed recordin g The compre ssed ratio is lower, and re cording speed is hig her.
AVerMedi a LX5000 Us er’s Manua l 45 Please fo llow the following steps to set the electro nics map: 1. Input th e back g round map: Pr ess “Edit" button and get into B MP, JPE G edit pro gram t o mo dify a nd edit t he bac kgroun d ma p. Or press the “input" button to input the ex isting map directly.
AVerMedi a LX5000 Us er’s Manua l 47 the fu rthe r inform ation . Do ma in Na me & Pas swo rd Enter the domain name and passw ord given in the process of regis tering a domain name or obtain them by asking network administrator . Modem Co nnecting Port : Please swat the modem conn ecting po rt in this column.
AVerMedi a LX5000 Us er’s Manua l 49 Click Add to cre ate an alarm and the detailed co nfiguration window will pop up: This window contains Cond ition and Action configurations. Actions will be perfor med according to the setup of conditions. T o add an alarm following the steps below: 1.
AVerMedi a LX5000 Us er’s Manua l 51 Provide information for each fi el d. • SMTP Serve r: Th e domai n na me of you r mail serv er o r IP a ddress. (eg. AV er Media.com.tw ) • From: The sender’ s email ad dress. • T o : The receiver ’ s email addres s.
AVerMedi a LX5000 Us er’s Manua l 53 Sche dule Rec ording Setup T o setup a recordi ng se ssion c lick th e Sche dule Re cording button and then click Sc he d ule Se tu p. Use th e diag ram below an d fol low the instru ctions to set u p a reco rdin g session.
AVerMedi a LX5000 Us er’s Manua l 55 section you plan as long as the Time is due. T o exercis e the p rior priv ilege of Schedule r , the Alarm will perform by the scheduled time even though it is not enabled in Alarm section of Syste m Configu ration.
AVerMedi a LX5000 Us er’s Manua l 57 4.3 Sys tem O pe rat ion 4.3. 1 Sta r t / Stop Record ing Clicking the Start/ Stop Re cording button in the main menu will activate surveillanc e according to the configurations in the Recordin g Setup page and Alarm Setu p and Sche dule Recordin g Setup pag e.
AVerMedi a LX5000 Us er’s Manua l 59 1. Use t he search ing cha rt, follow t he hard disk-> year, m ont h, day - >camera-> dis play all the file names of the save d recorded files based on hour , minute, and second time period . Press “Enter" to quit the searching chart, and prepare to play the recorded file.
AVerMedi a LX5000 Us er’s Manua l 61 T o enable this functio n, complete the following tasks: 1. Sele ct event Firs t pick out one event from Motion de tection, Video lo ss, Recording, Relay output, Sensor input, Phone alar m, Alarm, and All.
AVerMedi a LX5000 Us er’s Manua l 63 7. Sear ch Res ult Click Search Re sult to recall the previo usly searched list if you have exited Video searc h list .
AVerMedi a LX5000 Us er’s Manua l 65 number of relay/record ing, trigger/clear alarm, alarm condition, sensor /camera number and hard disk number . Clicking o n t he column header s will sort the rows in the order of the column infor mation, alternating between ascending and descending with every cl ick.
AVerMedi a LX5000 Us er’s Manua l 67 Backup file s There are hard d isk, type, size (KB), use%, total (KB) lists to view all of the files in every hard disk. a. De termine work ing type of hard d isk by clic king Change mode . It is allowed to have the hard disk run either recor ding or backup.
AVerMedi a LX5000 Us er’s Manua l 69 Click the page Cre ation ses sion/im age to view the working and free space. Eventually , burn th e CD by cli cking Master a nd write o n-the- fly . a. Click Stat isti cs to cal culate t he free spa ce of backu p devic e accord ing to the backup setting you build up prev iously .
AVerMedi a LX5000 Us er’s Manua l 71 1. Chose a map to view by clicking the map button … . 2. Check out Ca meras, Senso rs, Relays on th e map Focus on the desired event by click ing on the event button on the map.
AVerMedi a LX5000 Us er’s Manua l 73 Auto Pan Click this butto n to instruct the PTZ camera to begin AutoPan based on the AutoPan configurations: preset positi ons , sp eed , and tim e to stay . Preset positions are the d ifferent views that the camera will pan to.
AVerMedi a LX5000 Us er’s Manua l 75 Direct ion but tons Use thes e buttons to navigate the camera’s directional fo cus during surveillance . PTZ Came ra Nu mber Y ou may view t he status o f each PTZ camer a by cl icking on t he correspon ding PTZ Cam era Number bu ttons.
AVerMedi a LX5000 Us er’s Manua l 77 confirms the password is valid, then you can sta rt or st op the internet f unction. Intern et Sett ing Functi on: Please get into the system setting, and do the setting in the interne t setting.
AVerMedi a LX5000 Us er’s Manua l 79 Selec t Sec urity pag e to config ure Int e rnet and Local inter net sec tors respecti vely. Click Cust om Lev el butto n to p up up t he following di alog. Chec k Enable or Promp t radio butto n both i n Downl oad signed ActiveX control s and Download unsig ned ActiveX con trols.
AVerMedi a LX5000 Us er’s Manua l 81 When the remote transmitting cameras are more than the split display number , you can click to swit ch the screen to displa y the followin g camera s. F or example, the s erver has a ssigned ca mera 1, 2, 3, 5, 7, 10, 13, and 16, in total 8 c ameras for remote transmission.
AVerMedi a LX5000 Us er’s Manua l 83 Chapter 6 R emoteManager 6.1 Accessing R e mote M anager Y o u need to install the remote surveillance program R emoteManager from t he C D-ROM (See Chapt er 3 - Softw are Insta llat ion.
AVerMedi a LX5000 Us er’s Manua l 85 Display Mode Select a displa y mode t o arra nge the presenta tion of the screen . Full Screen 1 Channel 4 Channels 9 Chan nels 16 Channels No matter what channel m ode you choose, y ou can assembl e the channels as y ou wish by cli cking Channel St atus to meet the amount o f the mode.
AVerMedi a LX5000 Us er’s Manua l 87 1. Click Us er Management . The following window will appear : 2. Us e Add/ Delete/R ename button to arrange User field. 3. Det ermine a pa ssword and make a confi rmation . 4. Click Save to save the setup of password.
AVerMedi a LX5000 Us er’s Manua l 89 2. Change channel’ s names by di rectly click on . 3. Arrow dow n the list to select the Server ’s and Camera’s nam es for each channel. 4. Check Display to sh ow the i mages on the sc reen and Recording to enable the rec ording funct ion for each chan nel.
AVerMedi a LX5000 Us er’s Manua l 91 1. First dete rmine a UDP p ort (De fault 9190 ) to rece ive the images from se rve r . 2. Select TCP port connecti ng to serve r via Auto ass ignment or spe cify at least 32 por ts at a range from 1025 to 6553 5 for transferring image and receiving commands.
AVerMedi a LX5000 Us er’s Manua l 93 6.3 Operating Re moteM anage r 6.3. 1 Center M anageme nt Users c an take advantage of this sectio n to manage the connec table servers ’ detailed informatio n. The setting s hould be placed bef ore you commence configuring the system at the first time.
AVerMedi a LX5000 Us er’s Manua l 95 If the port number has been chan ged in se rver end, plea se del ete th e server and set a new one. 5. Y o u will be prompted to c lick OK in the fo llowing window to into the Camera S etup window o nce o ne of the us ers of s erver has bee n delete d.
AVerMedi a LX5000 Us er’s Manua l 97 Sli de Bar Y ou can drag the slide bar direct ly to the fr am e you wan t to pla y . / Zoom In/Out Click the b uttons to zoom in or out the images. Image Q uality Y ou can adjust the brightness, cont rast, hu e and satura tion.
AVerMedi a LX5000 Us er’s Manua l 99 Directi on Speed There are f our speeds t o deci de the movi ng speed of the P TZ camera during a djusti ng Dire ction C ontro l Focus in Decrease t he focal len gth of t he camera to focu s on the i mage. Focus ou t Increase th e focal lengt h of the came ra t o focus on the ima ge.
AVerMedi a LX5000 Us er’s Manua l 101 AVerMedi a LX5000 Us er’s Manua l 102 Chapter 7 AV e rMedia FAQs 1. Q: What is the limit for the length of the camera cable that is used to connect the camera to the LX5000 system? A: The maximum leng th is 150m for 5C coaxial cables.
AVerMedi a LX5000 Us er’s Manua l 103 7. Q: Why can’t I add a new mask? A: Y ou cannot add a new mask when previous masks are hidden. 8. Q: Do you offer a development kit fo r the LX5000 sy stem? A: We will provid e Center SDK in the near future. 9.
AVerMedi a LX5000 Us er’s Manua l 105 3. Use r Inform ation Please p rovide the following user information, Ho st N am e , Password , E-mail , Comp any , and Cou ntry to complete the regist ration proce dures. Note that Host Name and Domain Name (A V erMedi a.
AVerMedi a LX5000 Us er’s Manua l 107 This progr am can only v erify u n-compr essed bm p ima ge fil e C. verif y image file . Click 've rify' butt on to begi n the pr ocess AVerMedi a LX5000 Us er’s Manua l 108 D.
AVerMedi a LX5000 Us er’s Manua l 109 Using Ima geVerify pr ogram in Window 9 8SE / ME / 2000 Pro / XP Pro envi ronment If you are using Wind ows 98SE / Me / 2000 Pro / X P Pro system, pleas e open 'to ols' folder in Dig ital video surveillanc e system CD and execute 'ImageVerification.
AVerMedi a LX5000 Us er’s Manua l 111 (2) If the file is modified, it will display a wa rnin g dial og box. In result box, it will highlight the area which is been changed.
AVerMedi a LX5000 Us er’s Manua l 113 3. Go back to the Dial- up Networki ng wind ow and do uble - click th e connect ion you just create d. In the Connect to dial og box, enter a ny U ser name and the P assword set in ste p F of th e serve r’s ISDN setup proce dure.
AVerMedi a LX5000 Us er’s Manua l 115 5. Click the Finish button to complete the conn ection setup. 6. Go back to the Networ k and Dial- up Connec tions window and doub le-click the connec tion you just create d. In the dial og box, enter any User name and the P assword set in ste p E of t he server’ s ISDN setu p procedu re.
AVerMedi a LX5000 Us er’s Manua l 117 4. Select Conne ct using a dial- up modem a nd cli ck the Next button. 5. Enter the name of this connec tion and click the Next butto n. 6. Provide the ser ver’s teleph one num ber , including the area code, and click the Next button.
AVerMedi a LX5000 Us er’s Manua l 119 Limited Warranty AVerMedia TEC HNOLOGY, Inc. warra nts that this product to be free of d efects res ulting fro m faulty manuf acturing or com ponents under the fo llowing terms: WARRANTY LENGTH Labor is warranted for 15 months from the date of purchase.
Een belangrijk punt na aankoop van elk apparaat AVerMedia Technologies LX5000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen AVerMedia Technologies LX5000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens AVerMedia Technologies LX5000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding AVerMedia Technologies LX5000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over AVerMedia Technologies LX5000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van AVerMedia Technologies LX5000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de AVerMedia Technologies LX5000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met AVerMedia Technologies LX5000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.