Gebruiksaanwijzing /service van het product OQ234 van de fabrikant Sharper Image
Ga naar pagina of 22
Cable -F ree ™ In/Out Remote Thermometer with T rend Chart OQ234 Instructions Read and save these instructions..
Dear Sharper Image Customer , Thank you for your purchase of a Sharper Image product. W e appreciate your business very much. Please accept my personal assurance of your complete satisfaction with this product’ s quality and perfor mance. W e offer generous return privileges and excellent warranties on all our products.
• Do not immerse the unit in water . • Do not clean the unit with abrasive or corrosive material. • Do not subject the unit to excessive force, shock, dust, temper- ature or humidity . • Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnec- essary damage.
Battery Installation Remote Units: • Unscrew battery compartment cover for remote units first. • Designate a channel number (1, 2, 3) for each remote on the Channel Slide Switch; choose ˚F or ˚C temperature display unit on the ˚F/˚C Switch. • Insert two AAA (UM-4) batteries (included) into each battery compartment as specified.
temperature samplings at roughly 30-second intervals from the three remote units. If no signal is received, blanks will be displayed. Press the main unit’s CHANNEL and MEMORY simultaneously to enforce another search, or to synchronize the transmission and reception of the remote and main units if you find discrepancies in the temperatures shown.
Main Features A. OUTDOOR TEMPERA TURE - Displays current temperature, remote sensor unit. B. TEMPERA TURE TREND CHART - Outdoor CHANNEL 1 tem- perature variance display , last 12 hours.
C. INDOOR TEMPERA TURE - Shows the temperature collected indoors. D. ICE W ARNING ICON - Lights up when the ice warning func- tion is active. E. CHANNEL BUTT ON - Sets the remote sensor channel. F. MEMORY BUTT ON - T oggles between current, maximum and minimum temperatures.
A. LCD - Displays the current temperature monitored by the remote unit. B. LED INDICA T OR - Flashes when the remote unit transmits a reading . C. °F/°C SLIDE SWITCH - Selects between degrees F ahrenheit (°F) and Centigrade (°C).
D. CHANNEL SLIDE SWITCH - Designates the remote unit Channel 1, Channel 2 or Channel 3. E. RESET BUTT ON - Returns all settings to default values. F. BA TTERY COMP ARTMENT - Accommodates two UM-4 or AAA - size batteries. G. W ALL -MOUNT HOLDER - Supports the remote unit when wall-mounted.
1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the °F/°C slide switch. 4. Insert two UM-4 or AAA - size batteries. 5. Replace the battery compartment door and secure the screws.
Note: Once a channel is assigned to a unit, you can change it only by removing the batteries and repeating the above procedure. Battery Installation: Main Unit 1. Slide the battery compartment door open. 2. Insert two UM-3 or AA - size batteries. 3. Replace the battery compartment door .
4. Flip the table stand open and press the RESET button with a blunt stylus. This ensures easier synchronization between the transmission and reception of signals.
If no signals are received, blanks are displayed. Press CHANNEL and MEMORY simultaneously to enforce another search. This is useful in synchronizing the transmission and reception of the remote and main units.
The indoor temperature is shown on the bottom line of the dis- play . T emperature readings, received from a remote sensor , are displayed on the top line of the unit. Press CHANNEL to change from one channel to the next. If more than one remote sensor is being used, the unit can auto- matically scan all three of the outdoor channels.
The kinetic wave display on the channel icon indicates the status of reception. The unit is in searching mode T emperature readings are securely registered No signals If no readings are received from one particular channel for more than two minutes, blanks are displayed until further readings are successfully searched.
The maximum and minimum recorded indoor temperatures and those of each channel are automatically stored in memory . T o display them: 1. Press CHANNEL to locate the desired channel. 2. Press MEMORY to rotate through the maximum (MAX), mini- mum (MIN) and current temperatures.
The temperature variance for CHANNEL 1 for the past 12 hours is automatically scanned on the screen in six equal columns. The variance is represented in rows of degrees C above or below the current temperature at 0 Hr (current time) and 0°C (no variance).
To deactivate the ice warning function, slide the ICE W ARNING switch to OFF . T able Stand and W all Mount To place the main unit on a flat surface, flip open the table stand.
The remote unit comes with a removable table stand and a wall- mount holder . Reset Button The RESET button is used to enhance synchronization of signals after battery replacement or when the unit malfunctions. Use a blunt stylus to hold the RESET button down.
T emperature Measurement Main Unit Indoor T emperature Measurement Displayed IN temperature range 14.0°F to 158.0°F (-9.9°C to +70.0°C) Proposed operating range 23.
Number of remote units Maximum of three RF transmission range 100 meters T emperature sensing cycle 30 seconds User-selectable °F and °C P ower Main unit Use 2 UM-3 or AA 1.
What Is Covered This warranty covers any defects in materials or workmanship, with the exceptions stated below . How Long Coverage Lasts This warranty runs for 90 days from the date of original purchase.
Een belangrijk punt na aankoop van elk apparaat Sharper Image OQ234 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sharper Image OQ234 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sharper Image OQ234 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sharper Image OQ234 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sharper Image OQ234 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sharper Image OQ234 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sharper Image OQ234 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sharper Image OQ234 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.