Reduced wiring system EX250 - SEN1 Instruction Manual EtherNet/IP™ Compatible SI Unit URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA.
Contents Thank you for purchasing the SMC reduced wiring system EX250 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference.
2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.
4 5 Pr oduct Summar y Power supply for Output Block (for high wattage load) 24VDC Connecting to bus at upper level (EtherNet/IP) Power supply for output/input and control 24VDC Solenoid valve Output B.
6 7 SI Unit Model Indication Method Ti e-rod (2 pcs.) Accessory Note1 : For wiring method, refer to subsection "Wiring" (page 12) in this manual. Note2 : For display and setting method, refer to subsection "Display/Setting" (page 15) in this manual.
8 9 Mounting/Installation (continued ) Layout of the Input Block Position the Input Block on the left side of the SI Unit. Layout of the EX9 series Output Block / Power Block Position the Output Block / Power Block on the right side of the SI Unit and between the SI Unit and solenoid valve or End Plate R (on the Output Block side).
10 11 Specifications Sensor input area 1 0 I/O mapping Offset (word) Input data MSB LSB MSB LSB 15 8 70 0 1 Input area mapping 15 14 L : Fixed to Low Item Status Condition SP Solenoid power supply sta.
12 13 Wiring 43 2 1 1 34 2 M12 1 2 +Rx 3 - Tx 4 - Rx 1 2 3 4 5 6 7 8 Shield RJ45 6.7 47.3 45 2000 Model No. : EX9-AC020EN-PSRJ +Tx Wiring diagram Cable core wire external color Terminal No.
14 15 Wiring ( continued ) 24VDC 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blue : 24VDC (for input and control) Black : 0V (for input and control) Cable P ar t No .
16 17 12345678 ON 1 0 IP address 192.168.0.X 1 0 1 0 1 0 1 2 0 0 1 1 1 1 3 0 0 0 0 1 1 4 0 0 0 0 1 1 Remote control * 1 X 3 2 1 14 DHCP mode * 2 SW1 Communication setting CLEAR/HOLD Manual set up of I.
18 19 Input Bloc k Model Indication Method EX250 IE Block type 1 2 3 Input points : 2, M12 connector (2pcs.) Input points : 4, M12 connector (2pcs.) Input points : 4, M8 connector (4pcs.) Input Block Model indication method Pa rt Names No. Part names Application 1 Input equipment connector Connects the input equipment such as sensor, etc.
20 21 Wiring EX250-IE3 EX250-IE1/2 EX250-IE1 (M12 connector, 5 pin, Socket) EX250-IE2 (M12 connector, 5 pin, Socket) *1) Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly input from the input connector "0".
22 23 Displa y/Setting EX250-IE1 EX250-IE2/IE3 0 0 1 1 EX250 EX250 0 0 1 1 2 2 3 3 EX250 EX250 Display Description PWR Lights up Power supply for sensor is ON. Off Power supply for sensor is OFF. 0, 1, 2, 3 Lights up Sensor signal input corresponding to the number is ON.
24 25 Pa rt Names T ie-rod (2 pcs.) Accessory T ie-rod (2 pcs.) Accessory W aterproof cap (for socket)(1 pc.) Dimensions ( unit : mm ) 59.8 72.6 21 Output Block 59.8 80.3 21 PWR PWR Po wer Bloc k Mounting/Installation Refer to subsection "Mounting/Installation" (page 7) in this manual.
26 27 Wiring ( continued ) Output connector pin lay out EX9-OET1, EX9-OEP1 (M12 connector, 5 pin, Socket) Output No.1 *1 Output No.0 NC *2 1 NC *2 3 GND 5 NC *2 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5.
28 29 Wiring ( continued ) M12 connector, 5 pin, Reverse key 1 Power supply for output (24VDC) 2 Power supply for output (0VDC) 5 Ground ( 3 Power supply for sensor (24VDC)) * ( 4 Power supply for sen.
30 31 Wiring ( continued ) Displa y Output Block PWR PWR Po wer Bloc k The Power Supply Cable (for Power Supply Connector of Power Block) is a bypass cable which can be used when the Power Block is positioned next to the SI Unit.
32 33 Option ( continued ) Waterproof Cap Mounted on the unused ports of the Input Block, Output Block and Power Block. The proper use of this Waterproof Cap can achieve IP67 Enclosure. (The Waterproof Caps are delivered together with the Power Block as accessories.
34 Tr oubleshooting ( continued ) MS LED status Normal status : Green light ON Fatal failure : Red light ON 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch.
Een belangrijk punt na aankoop van elk apparaat Sierra Monitor Corporation EX250-SEN1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sierra Monitor Corporation EX250-SEN1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sierra Monitor Corporation EX250-SEN1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sierra Monitor Corporation EX250-SEN1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sierra Monitor Corporation EX250-SEN1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sierra Monitor Corporation EX250-SEN1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sierra Monitor Corporation EX250-SEN1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sierra Monitor Corporation EX250-SEN1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.