1 Introduction The 2-Port RS-232/422/485 Serial over IP Ethernet Device Server is designed to operate serial ports over 10/100 Mbps Ethernet networks, transmitting via TCP/IP protocol. Features and Benefits • ARM Cortex-M3 32-bit high performance CPU • Auto reset on Idle detection • Easy to use Web Server Management • 115.
2 RS-232/422/ 485 (Port 2) RS-232 (Port 1) DC-In (power) LAN Reset Button LED Indicators (SYS, Port-2, Port-1) Package Contents • 2-Port RS-232/422/485 Serial over IP Ethernet Device Server • Powe.
3 Device Server Configuration Follow the instructions below to configure your Serial over IP Ethernet Device Server , if needed. The default IP address of the Serial over IP Ethernet Device Server is 192.
4 4. Click the Modify MAC button and change the MAC address from the prompted Dialog Frame window, if needed. 5. Click the Web Browse button to open the Web Browser Configuration webpage. See Figure 6. Figure 4 1. Double click IP Search Utility in the included software CD, then double click CVBrowser.
5 Type in password and click the Login button, then make your changes from the Web Browser Configuration webpage. See the section for more information. Web Console Configuration In addition to basic IP address and subnet mask, specific device settings can be set through HTTP protocol with popular browsers, e.
6 • Firmware version : The Serial over IP Ethernet Device Server's firmware version is identified by date code. • Serial number : Product serial number as provided by the factory • Ethernet.
7 • Subnet mask : Subnet mask of 255.255.255.0 is usually used for small networks, 255.255.0.0 for larger networks. If your IP address is provided by an ISP or network administrator, please obtain that information and enter it correctly.
8 Figure 8 • Serial I/O Port 1 (RS-232) : One RS-232 serial port for connecting RS-232 serial device • Serial I/O Port 1 (RS-422/485) : One RS-422/485 serial port for connecting RS-422/485 serial device • Local Port : A socket port assigned to the serial port.
9 • Interface - Port 1 - RS232 GTxD, RxD for data stream, no flow control - RS232 (RTS/CTS) GTxD, RxD for data stream, RTS/CTS for flow control • Interface - Port 2 : The Auto Detect feature will .
10 Device Server Updated Press the Update button after you complete your changes. The Serial over IP Ethernet Device Server will save all setting into internal non-volatile memory and then reboot. The Web Console webpage will refresh in around 5 seconds.
11 COM Port Setup IMPORTANT : Copy the VirtualCOM folder from your driver CD to your PC's hard drive, then follow the instructions below to add the virtual COM port. 1. Open the VirtualCOM folder, double click 32-bit or 64-bit folder ( based on your system), then double click VSerPortConsole .
12 4 . Click Install this driver anyway or Continue Anyway , then a COM port would be assigned. 5. Right click under the assigned COM port and click Add Net . Figure 12 COM 3 Add Net 6. Type in the IP address of the Serial over IP Ethernet Device Server in the Remote Address field.
13 8. A (Unconnceted) TCP Client... will be established. Figure 14 (Unconnected) TCP Client... 9. Right click on the Virtualserial Port Console , click Add Port , then follow steps 3-7 to add the second serial port, if needed. 10. Close the Virtualserial Port Console and reopen it to make sure the COM port is successfully added.
14 Figure 15 Enter a terminal name, choose an icon, and press OK button. Figure 16.
15 Figure 17 Sele ct the assigned COM port at the Connect using field, see Figure 17 . For example, if the virtual COM port was assigned COM 3, then select COM 3. Figure 18 Select the same values with the Controller Setup to the COMX Properties , then click OK .
16 If Hyper Terminal connects with the Serial over IP Ethernet Device Server successfully, the time clock at the lower left corner, Connected hh:mm:ss , will start counting, see Figure 19 . Figure 19 H yper Terminal for COM Port Initiate another Hyper Terminal as a COM Port Terminal.
17 Wiring Architecture PC Ethernet switch / hub RS-232 RS-232 (RTS / CTS) LAN cable Serial Device Rx Tx GND RTS CTS Serial to TCP/IP Tx Rx GND CTS RTS Serial Device Rx Tx GND Serial to TCP/IP Tx Rx GN.
18 FAQ Q1 . Why can't ETM.exe detect the Serial over IP Ethernet Device Server on the network? A1 . Please check the followings: (1) The power adapter is properly connected and powerd on ; (2) Th.
19 Technical Support and Warranty QUESTIONS? SIIG ’ s Online Support has answers! Simply visit our web site at www.siig.com and click Support . Our online support database is updated daily with new drivers and solutions. Answers to your questions could be just a few clicks away.
About SIIG, Inc. Founded in 1985, SIIG, Inc. is a leading manufacturer of IT connectivity solutions (including Serial ATA and Ultra ATA Controllers, FireWire, USB, and legacy I/O adapters) that bridge the connection between Desktop/ Notebook systems and external peripherals.
Een belangrijk punt na aankoop van elk apparaat Siig ID-DS0711-S1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Siig ID-DS0711-S1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Siig ID-DS0711-S1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Siig ID-DS0711-S1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Siig ID-DS0711-S1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Siig ID-DS0711-S1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Siig ID-DS0711-S1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Siig ID-DS0711-S1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.