X X L L - - 2 2 0 0 0 0 0 0 OIL-FIRED W A TER BOILERS/NO . 2 OIL INST ALLA TION AND OPERA TING INSTR UCTIONS SAFETY W ARNING: KEEP BOILER AREA CLEAR AND FREE FROM COM- BUSTIBLE MA TERIALS, GASOLINE AND O THER FLAM- MABLE V APORS AND LIQUIDS.
XL-2000 2 XL-20 0.65 91,000 78 68 8 x8x15 6 x 15 83.56 8 11 / 16 4 9 / 16 6¶ 1 1 / 4 25 3 / 8 XL-30H 0.85 119,000 104 90 8 x8x15 6 x 15 86.00 12 3 / 16 6 5 / 16 61 1 / 4 28 7 / 8 XL-30 1.00 140,000 121 105 8 x8x15 6 x 15 85.04 12 3 / 16 6 5 / 16 6 1 1 / 4 28 7 / 8 1.
T HE INST ALLA TION INSTRUCTIONS IN THIS MANU AL ARE ABBREVIA TED . SEE THE FRONT CO VER OF THIS MANU AL FOR REFERENCES TO CODES AND ST AN- D ARDS. BOILER LOCA TION Provide a le vel, solid f oundation f or the boiler . Location should be near the chimney so that the Flue Pipe Connector or B reeching to the chimney is short and direct.
tion, heavy sooting and health hazards . Any oil-fired boiler must ha ve a steady dr aft* and an ample supply of combustion air at all times during fir ing. If air supply or chimne y draft* is unreliable , CO 2 and ov erfire draft* will change unpredictably .
XL-2000 5 Figure 3a. Appliances located in confined spaces. Air from inside the building. See T able 2 (2.3). Figure 3b. Appliances located in confined spaces. Air from out- doors. See T ab le 2 (2.4). Figure 3c. Appliances located in confined spaces.
XL-2000 6 The opening size recommendation just giv en is for guidance only . It is the installer’ s responsibility to provide air for comb us- t ion and ventilation to all appliances , under all operating con- ditions, f or each installation. See NFP A 31, latest edition for more specific details.
DOMESTIC HO T W A TER F or Indirect-fired storage water heater application, see S lant/Fin publication WH-10, Sizing Guide WH-SG and Installation manual WH-40. The installation manual includes se ver al control systems and relay centers f or space and domestic water heating in addition to plumbing.
smoke and dry soot formation in the fire box. F . If smoke reading is satisf actor y , but CO 2 can not be increased to a satisf actor y lev el (12%) or overfire dr aft of 0 .
6. Use the flue br ush to clean the pinned fluew ays b etween the sections.† A wire brush ma y be used to remov e any carbon accumulation that may ha ve d e veloped in the comb ustion chamber. V acuum the loose soot and debris from the boiler . 7. Inspect the burner combustion head.
XL-2000 10.
BURNER D A T A—CARLIN BURNERS FOR P A CKA GED BOILERS ONL Y XL-2000 11 XL-20 99-FRD 0.65 0.65 70° A DELA V AN 100 0 50 Closed 71399-00F-XL-20 0.65 70° W DELA V AN 100 0 50 Closed XL-30 99-FRD 1.00 1.00 70° A DELA V AN 100 2 80 Closed 71399-00F-XL-30 1.
XL-2000 12 BURNER D A T A—BECKETT BURNERS FOR P A CKA GED BOILERS ONL Y XL-20 (4) AFG F0 0.65 0.65 80° A DELA V AN 100 7 Blank/Closed 3 3 / 8 SF2201 XL-30H AFG F3 0.85 0.85 70° W DELA V AN 100 6 Blank/Closed 2 3 / 4 SF2204 XL-30 AFG F3 1.00 1.00 80° W DELA V AN 100 8 0 2 3 / 4 S F2202 1.
BURNER DA T A - RIELLO BURNERS FOR P A CKA GED BOILERS ONL Y (RIELLO R-40 SERIES W/SHORT TUBE) † Air shutter and head settings shown are appro ximate ONL Y .
XL-2000 14 BURNER DA T A - RIELLO (continued) REGULA TION OF THE TURBULA TOR AND AIR SHUTTER F OR PROPER COMB USTION T urbulator Setting 1. Loosen n ut, 1, then turn the screw , 2, until the index marker , 3, is aligned with the correct inde x number .
SLANT/FIN CORPORA TION, Green vale, N.Y . 11548 • Phone: (516) 484-2600 F AX: (516) 484-5921 • Canada: Slant/Fin L TD/L TEE, Mississauga, Ontar io www .
Een belangrijk punt na aankoop van elk apparaat Slant/Fin XL-2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Slant/Fin XL-2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Slant/Fin XL-2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Slant/Fin XL-2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Slant/Fin XL-2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Slant/Fin XL-2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Slant/Fin XL-2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Slant/Fin XL-2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.