Gebruiksaanwijzing /service van het product SG-PAC-10E5 van de fabrikant Soleus Air
Ga naar pagina of 15
10,000 BTU Portable Air Conditioner Operating Instructions Model No. SG-P AC-10E5 Reference No. KY-100E5 V.121016.
Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product.
S PEC IFICA TIONS • The cooling c apacity is measured at an ambient tem perature of DB 86 °F, WB 78 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in coolin g mode. • Power consum ption is measured when the fan runs at the highest speed setting.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Inter r uption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the lo ad side and a LCDI attachm ent plug on the line side.
PRODUCT DIAGRAM Control Panel Louvers Louver Guides Casters Power Cord Filters Upper Air Intake Lower Air Intake Remote Control Holder Air Exhaust Vent 5.
P ARTS & WINDOW KIT ASSEMBL Y PARTS EXHAUST HOSE & ADAPTERS ASSEMBLY & INSTALLATION INSTALLATION When the uni t is operating as an air conditioner or deh u m idi fier, the window kit a nd exhaust h o se must be installed. When the unit is operating in fan mode, the window ki t and exhaust hose do not need to be inst alled .
SINGLE HOSE WINDOW KIT INSTALLATION When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If be nding or an angle is necessary , use single 90 ° angles like the pictures above.
CONTROL P ANEL, DISPLA Y , & OPERA TING INSTRUCTIONS CONTROL PANEL & LED DISPLAY CONTROL PANEL OPERATING INSTRUCTIONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
1) Power On and Off - Press the ON/OFF (POWER) butto n once to manually turn the unit on . Press the Power button once more to turn the unit off. When you manually power the unit on an d off by pressing the ON/OFF button, the preset timer will be cancelled.
5) Auto-on Timer: When the air conditione r is off, it can be set to automatically turn on in 30 minutes to 24 hou rs at the previous set mode and fan setting. To set the Auto-on Timer, press the TIMER butt on on the unit or rem ote control. Each touc h of the +/- buttons on the remote will change the timer setting in 30 minute increments (.
When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture that is un able to be evaporated is placed in a small bank up water tank in- side the unit.
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an el ectrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volum e may reduce. It is recommended to clean the filter onc e every two weeks or as needed.
PROBLEM The Air Conditioner will not start POSSIBLE CAUSES The air conditioner is unplu gged o r not connected well. The fuse is blown/circuit breaker is tripped.
PROBLEM The LCD Display is showing “E5” POSSIBLE CAUSES Low Voltage Protection SOLUTIONS • Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service.
W ARRANTY One Year Limited Warranty Soleus International Inc. warrants the ac comp anying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications sp ecified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.
Een belangrijk punt na aankoop van elk apparaat Soleus Air SG-PAC-10E5 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Soleus Air SG-PAC-10E5 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Soleus Air SG-PAC-10E5 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Soleus Air SG-PAC-10E5 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Soleus Air SG-PAC-10E5 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Soleus Air SG-PAC-10E5 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Soleus Air SG-PAC-10E5 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Soleus Air SG-PAC-10E5 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.