Gebruiksaanwijzing /service van het product 232SDD16 van de fabrikant B&B Electronics
Ga naar pagina of 27
232SDD16-1005 Manua l Cover Page B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 RS-232 Digital I/O Module Model 232SDD16 Documentat ion Number 232SDD16-1005 pn#3604-r1 This product Designed and Manufactur ed In Ottawa , Illinois USA of domestic and impor ted parts by B&B Electronics Mfg.
232SDD16-1005 Manua l Table of Contents i B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Table of Contents Chapte r 1- Introduction ........................... ................ 1 232SDD16 Fe atures .
232SDD16-1005 Manua l 1 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Chapter 1- Introduction 232SDD16 Features The 232SDD16 is a ge neral purpose contro l module that is connected to your computer’s RS-232 serial port.
232SDD16-1005 Manua l 3 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 232SDD16 Speci ficat ions I/O Lines Total: 16 (Factory default = inputs) Digital Inputs Voltage Range: 0 Vdc to 5 Vdc Low Voltage: 1.
232SDD16-1005 Manua l 5 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Chapter 2 - Connections This chapter will cover the connections re quired for the 232SDD16. There are thre e sets of conne ctions: digital I/ O, serial port, and power supply.
232SDD16-1005 Manua l 7 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Table 2.2 - RS-232 Connector Pinout DB-25S Pin # Signal Signal Direction at 232SDD16 Notes 2 Transmit Data (TD) Input Connection is required.
232SDD16-1005 Manua l 9 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Chapter 3 - Comm ands There are only two commands required to control the 232S DD16: set output lines, and read I/O li nes.
232SDD16-1005 Manua l 11 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 A byte represents an eight-bit binary numbe r (1111 1111 ), therefore each byte can repre sent eight I/O lines. Each bit is assigned a bit position and a weight (value ).
232SDD16-1005 Manua l 13 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Command: !0SO Argument: {I/O msb}{I/ O lsb} Response: none ASCII Example: !0SOUA Dec. Example: !0S O<85><65> Hex. Example: !0SO <55><41> Bin.
232SDD16-1005 Manua l 15 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Command: !0RC Argument: none Response: definit ion of th e sixteen I/O lin es in two 8 bit bytes, and the power-up states in two 8 bi t byt es.
232SDD16-1005 Manua l 17 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Chapter 4 - I/O Interfacing This chapter will explain "HIGH" and " LOW" states and show some general examples of how to interf ace to the I/O lines.
232SDD16-1005 Manua l 19 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Figure 4.4 - Isolated Solid State Input Digital Outputs Digital outputs are used to turn exter nal devices on or of f. Digit al outputs are CMOS/TTL compatible and oper ate betwe en 0Vd c and +5Vdc.
232SDD16-1005 Manua l 21 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Chapter 5 - Softwar e This chapter will be divided into t wo sections. The first section covers programming techn iques for constructing a command string, receiving data and manipulatin g dat a in QuickBAS IC.
232SDD16-1005 Manua l 23 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Step 5 - Determining the I / O line de fin itio ns: MSdefs = MSdefs AND mask.
232SDD16-1005 Manua l 25 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Define I/O Lines Command Step 1a - Cons truct the comma nd string: Define an.
232SDD16-1005 Manua l 27 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Demonstration Program The 232SDD16 Demonstration (SDD16) Program (IB M PC or Compatible) provi des the user with example s of how to receive and transmit commands to the 232 SDD16.
232SDD16-1005 Manua l Appendix A A-1 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 APPENDIX A ASCII Character Codes A-2 Appendix A 232SDD16-1005 Ma.
232SDD16-1005 Manua l Appendix B B-1 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 APPENDIX B Hexadecimal/Decimal Conversions B-2 Appendix B 232SDD.
232SDD16-1005 Manua l Appendix B B-3 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Hexadecimal to Decima l Conve rs ion: Decimal = (1st Hex d igit .
232SDD16-1005 Manua l Appendix C C-1 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 APPENDIX C Interface Modules for SDD16 Models C-2 Appendix C 232.
232SDD16-1005 Manua l Appendix C C-3 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Table C.1 - DTB25 Connections DB-25P Pin # Function T.B. # DB-25P Pin # Function T.B. # 1 Unused. 1 14 I/O #15 14 2 Unused.
232SDD16-1005 Manua l Appendix C C-5 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 DBM16 Interfacing This section will show some general examples of how to interface the DBM16 I/O lines t o external d evices.
232SDD16-1005 Manua l Appendix C C-7 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Figure C.6 - Isolated Solid State Input Outputs Digital outputs are used to turn "ON" or t urn "O FF" external devices.
232SDD16-1005 Manua l Appendix C C-9 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 DBM16 Specifications I/O Lines Total: 16 (Fa ctory default - set to inpu ts) Inputs Voltage range: 0Vdc to +50Vdc Low Voltage: 0Vdc to +1.
232SDD16-1005 Manua l Appendix C C-11 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104.
232SDD16-1005 Manua l Appendix D D-1 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Appendix D Adding Data Field Confirmation D-2 Appendix D 232 SDD.
232SDD16-1005 Manua l Appendix D D-3 B&B Electronics -- PO Box 1040 -- O ttawa, IL 61350 PH (815) 433-5100 - - FA X (815) 433-5 104 Table D-1 Extended Commands Function Co mmand Response Read I /O.
Een belangrijk punt na aankoop van elk apparaat B&B Electronics 232SDD16 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen B&B Electronics 232SDD16 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens B&B Electronics 232SDD16 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding B&B Electronics 232SDD16 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over B&B Electronics 232SDD16 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van B&B Electronics 232SDD16 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de B&B Electronics 232SDD16 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met B&B Electronics 232SDD16 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.