VPL-PX35/PX40/FX51 ! W ARNING This manual is intended f or qualified ser vice personnel only . T o reduce the risk of electr ic shock, fire or injury , do not perf or m any ser vicing other than that contained in the operating instructions unless you are qualified to do so.
1 VPL-PX35/PX40/FX51 Table of Contents 1. Introduction .............................................................................................. 1 2. RS-232C 2-1. Communication Specifications ......................................................
2 VPL-PX35/PX40/FX51 Appendix A. Setup Method For VPL-PX35 and PX40 A-1. Command ..................................................................................................... 18 A-1-1. Setting ..................................................
1 VPL-PX35/PX40/FX51 EVEN Parity.....Total number of “1”s from D0 to D7 is an even number. D4 D5 D6 D7 (MSB) (LSB) (EVEN) BIT PARITY STOP BIT START D3 D2 D1 D0 1. Introduction This protocol manual describes the basic configuration and basic operations of various commands used for projector.
2 VPL-PX35/PX40/FX51 2-2. Command Block Format The code from B0 to B7 as described below are transmitted. START CODE : 0 x A9 B0 B1 B2 B4 B3 DATA ITEM NUMBER ACK / NAK ITEM NUMBER SET / GET ACK DUMMY .
3 VPL-PX35/PX40/FX51 2-3. Block Format START CODE B0 B1 B2 B4 B3 DATA ITEM NUMBER SET / GET CHECK SUM END CODE B5 B6 B7 START CODE B0 B1 B2 B4 B3 DUMMY DATA ACK / NAK ACK CHECK SUM END CODE B5 B6 B7 S.
4 VPL-PX35/PX40/FX51 2-5. Communication Procedure 2-5-1. Outline of Communication All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the command block format. Communication is started by the issue of a command at CONTROLLER and ended when the return Data is sent to CONTROLLER after DEVICE receives the command.
5 VPL-PX35/PX40/FX51 2-6. Communication Rules . When sending a command from CONTROLLER, the return Data from PROJECTOR should be received first before sending the next command. Even if the next command is sent before receiving the return Data, since PROJECTOR will not be able to receive that command, it does not return a response to CONTROLLER.
6 VPL-PX35/PX40/FX51 3. NETWORK 3-1. Introduction This section describes the specifications, performance and operations of the network service that is going to be installed in the target projector.
7 VPL-PX35/PX40/FX51 3-1-2. Remote Control The remote control service is provided that can control the target equipment from remote location via network. The SDCP protocol that serves to acquire the basic information such as equipment name and serial numbers is installed in this projector.
8 VPL-PX35/PX40/FX51 3-2. SDAP Protocol This section describes the SDAP packet structure. Fig.1 Packet structure 1) Header The header consists of ID (16 bit), version (8 bit) and category (8 bits). Fig. 2 Header ID It is fixed to “ DA ” . Version This indicates the version number of protocol.
9 VPL-PX35/PX40/FX51 3-3. SDCP Protocol This section describes the packet structure of version 2. Fig. 1 Packet structure 3-3-1. Format 3-3-1-1. Header The header consists of Version (8 bits) and Category (8 bits). Fig. 2 Header structure Version This indicates the version number of protocol.
10 VPL-PX35/PX40/FX51 3-3-1-3. Command This section describes the format of the request command and the response command. (1) Request This section describes the format of the request command that is issued from the host PC to the projector.
11 VPL-PX35/PX40/FX51 00h Item No. n Set Data (n byte) Request Item No. Data Length Data OK (01h) Item No. 0 3-3-1-4. SET Request The SET request is used to set a new value in the specified item. Details of the request and the response are described below.
12 VPL-PX35/PX40/FX51 3-3-2. Items Category Contents SET GET 00**h Used to control and to change the various setups. OO 01**h Used to acquire the status. O 03**h Used to reset memory. O 17**h Sircs (15 bit category) O 19**h Sircs (20 bit category) O 80**h Used to acquire equipment information.
13 VPL-PX35/PX40/FX51 3-3-2-3. Network Information Acquisition (90**h) Used to acquire the network setup information. Lower bytes Contents SET GET 00h MAC Address O 01h IP Address O 02h Subnet Mask O .
14 VPL-PX35/PX40/FX51 3-3-3. Error Code The error code list is shown below with a detailed description of each. Category Error Error Code Item Error (01**h) Invalid Item 01h Invalid Item Request 02h I.
15 VPL-PX35/PX40/FX51 3-3-3-1. Item Error This error occurs when the Item No. of a request is illegal or its Data is illegal. The conditions for occur- rence of the respective errors are shown below. Invalid Item An unsupported Item No. is specified. Example 1: The unsupported category 0xA ** is specified.
16 VPL-PX35/PX40/FX51 3-3-3-3. Request Error This error occurs when Header or Command is illegal. The conditions of occurrence of the respective errors are shown below. Invalid Version The version of the Header is other than 2. n When another version is supported, an error occurs in all versions other than the supported version.
17 VPL-PX35/PX40/FX51 3-3-3-5. Comm Error This is an error in communication with the main control microprocessor of the display. Timeout Reception Data is not returned after Data is sent. Check Sum Error A check sum error occurred in the main control microprocessor of the display.
18 VPL-PX35/PX40/FX51 Appendix A. Setup Method For VPL-PX35 and PX40 Establishing the network setup such as IP address can be implemented from the PC browser, and the information such as installation location can be viewed on the PC browser. A-1. Command A-1-1.
19 VPL-PX35/PX40/FX51 A-1-2. Display Enter the following command using the format shown below in a browser as URL, and then value of the setting item is displayed. Format http://IP address/Item IP address The IP address that is assigned to the network block Item Name of the setup item Response The following HTML is returned.
20 VPL-PX35/PX40/FX51 A-2. Setting Command Each setting item is described below. Equipment information Item Description Default location Sets location of the equipment installation. (Maximum 24 alphanumeric characters) _ Community Sets the equipment community.
21 VPL-PX35/PX40/FX51 <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte VIDEO 00h 00h Set/Get S VIDEO 00h 01h INPUT 00h 01h INPUT A 00h 02h.
22 VPL-PX35/PX40/FX51 <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte STANBY 00h 00h Get only START UP 00h 01h STARTUP LAMP 00h 02h POWER.
23 VPL-PX35/PX40/FX51 (VPL-PX35, PX40) <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte Input 00h 01h Video 00h 00h Set/Get S-Video 00h 01.
24 VPL-PX35/PX40/FX51 <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte STATUS ERROR 01h 01h NO ERROR 00h 00h Get only LAMP ERROR 00h 01h F.
25 VPL-PX35/PX40/FX51 List of SIRCS CODE (1) 15BIT Category (VPL-FX51 only) <Table 4> POWER ON/OF HUE + PURPLISH HUE _ GREENISH SHARPNESS + SHARP SHARPNESS _ SOFT ADJ R ADJ G ADJ B W/B GAIN W/B .
26 VPL-PX35/PX40/FX51 (2) 20BIT Category (VPL-FX51 only) <Table 5> x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE LENS ZOOM LENS SHIFT LENS FOCUS FREEZE LE.
27 VPL-PX35/PX40/FX51 (3) 15BIT Category (VPL-PX35, PX40) <Table 6> POWER ON/OF AUDIO MUTING VOLUME- DOWN VOLUME+ UP HUE + PURPLISH HUE _ GREENISH SHARPNESS + SHARP ADJ G ADJ R ADJ B W/B GAIN W/.
28 VPL-PX35/PX40/FX51 (4) 20BIT Category (VPL-PX35, PX40) <Table 7> x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE FREEZE LENS CONT TOGGLE DIGITAL ZOOM + V.
VPL-PX35/PX40/FX51 The material contained in this manual consists of inf or mation that is the proper ty of Sony Cor poration. Sony Corporation e xpressly prohibits the duplication of any portion of t.
Printed in Japan Son y Cor por ation 2003. 4 16 B&P Company ©2002 VPL-PX35 (SY) VPL-PX40 (SY) VPL-FX51 (SY) E 9-870-346-64.
Een belangrijk punt na aankoop van elk apparaat Sony VPL-FX51 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sony VPL-FX51 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sony VPL-FX51 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sony VPL-FX51 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sony VPL-FX51 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sony VPL-FX51 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sony VPL-FX51 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sony VPL-FX51 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.