Linear Motors Installation & Operating Manual 1/01 MN1800.
T able of Contents T able of Contents i MN1800 Section 1 General Information 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview 1-1 .
ii T able of Contents MN1800 Bearing Maintenance 2-31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recirculating Bearing Rail And Block 2-31 . . .
Section 1 General Information General Information 1-1 MN1800 Overview This manual contains general procedures that apply to Baldor Linear Motor products.
1-2 General Information MN1800 Safety Notice : This equipment contains high voltage! Electrical shock can cause serious or fatal injury . Only qualified personnel should attempt installation, operation and maintenance of electrical equipment.
General Information 1-3 MN1800 Receiving Each Baldor motor is thoroughly tested at the factory and carefully packaged for shipment. When you receive your motor , there are several things you should do immediately .
1-4 General Information MN1800.
Section 2 Installation & Operation Installation & Operation 2-1 MN1800 Overview Installation should conform to the National Electrical Code as well as local codes and practices. When other devices are coupled to the motor , be sure to install protective devices to prevent accidents.
2-2 Installation & Operation MN1800 LMAC Linear Induction Motor General Description: Single or three phase, linear AC induction motor primary . Construction: Epoxy encapsulated and steel laminated.
Installation & Operation 2-3 MN1800 LMBR Series Brush DC Linear Servo Motor Mounting The motor primary must be aligned (parallel) to the equipment guide ways within 0.005 ″ (0.127mm) on each end. Use gauge blocks and shims as necessary . Precise parallel alignment of the motor to the equipment guideways is required.
2-4 Installation & Operation MN1800 LMBL Series Brushless Linear Iron Core Servo Motor Installation Refer to Figure 2-1. 1. Install the magnet assembly onto the machine mounting base. 2. With the slide assembly removed from the rails, install the coil assembly onto the slide, tightening the mounting screws.
Installation & Operation 2-5 MN1800 LMBL Series Continued Brushless Linear Iron Core Servo Motor Continued Multiple Coil Assembly Operation In addition to maintaining an air gap, multiple coil assemblies must also maintain a spacing factor of 1.8 ″ .
2-6 Installation & Operation MN1800 LMBL Series Continued Brushless Linear Iron Core Servo Motor Continued Modular Magnet T rack Installation Refer to Figure 2-3. Some magnets are provided in modular segments. This is the recommended procedure to install these modular magnet track sections.
Installation & Operation 2-7 MN1800 LMBL Series Continued Brushless Linear Iron Core Servo Motor Continued Modular Magnet T rack Continued 4. Install the remaining magnet track sections on the base plate. See Figure 2-5. 5. Remove the air – gap setting shim from the magnet track before use.
2-8 Installation & Operation MN1800 LMCF Series Brushless Linear Cog Free Servo Motor 1. Install the coil and magnet assemblies. While mounting the coil, be sure to adjust coil assembly so it is centered within the magnet assembly with equal air gap in the vertical and horizontal positions.
Installation & Operation 2-9 MN1800 LMCF Series Brushless Linear Cog Free Servo Motor Continued LD9073A00 Hall Sensor Cable Connections (6 pin to flying leads) Pin# Color Description 1 Black C 2 Red B 3 N.
2-10 Installation & Operation MN1800 LMNM Moving Magnet T ype Non Commutated DC Linear Servo Motor General Description: Bi – directional DC linear motor with integral bearing.
Installation & Operation 2-1 1 MN1800 LMPY Series Polynoid Linear Motor Holding Option Mounting: The rectifier package is wired externally in the stator circuit. For 1 15/60Hz, rectifier package CO0126A00 is provided. For 230/60Hz, rectifier package CO0125A00 is provided.
2-12 Installation & Operation MN1800 LMPY Series Continued Polynoid Linear Motor Holding Option Continued Operation Considerations The motor must always be operated within the specified operating parameter limits. Exceeding those limits will permanently damage the motor .
Installation & Operation 2-13 MN1800 LMSS Series Linear Stepper Roller Bearing Motor Installation Prior to placing the Forcer on the Platen both surfaces must be cleaned. Use this method: 1. Apply masking tape to lamination surface of the Forcer to remove any metallic contaminants.
2-14 Installation & Operation MN1800 LMSS Series Continued Air Bearing Motor Cleaning the Forcer and Platen Prior to placing the Forcer on the Platen both surfaces must be cleaned. Use this method: 1. Apply masking tape to lamination surface of the Forcer .
Installation & Operation 2-15 MN1800 LMDS Series Dual Axis Linear Stepper Motor Items Required but NOT Included 1. A regulated 80 PSI air supply with a 5 micron filter for each motor . A water separator is also required. 2. T wo or four phase, 2 ampere (micro) stepper motor driver/controller for each motor .
2-16 Installation & Operation MN1800 Leadwire Connection 1 2 3 4 5 6 7 8 9 Female (D Sub) 2 3 4 5 6 7 8 9 Female (D Sub) 1 10 11 12 13 14 15 17 16 18 19 20 21 22 23 24 25 Color Pin# Description (2.
Installation & Operation 2-17 MN1800 LSE Series Enclosed Position Stage General Description: Single axis linear stage with linear motor , linear bearings, linear encoder , limit switches, cable ca.
2-18 Installation & Operation MN1800 A Y1775A00 LSE, Encoder (RGH24) & Hall Connections for LinDrive/MintDrive (15 pin to flying leads) Color Pin# Description Green 1 A+ Blue 2 B+ Pink 3 C+ Wh.
Installation & Operation 2-19 MN1800 Internal Connections Leadwire Connection Limit Switch Pigtails 671P OUT L 1 2 3 4 1 2 3 4 671P OUT L 671P OUT L Home H – Limit Limit Color Pin# Description B.
2-20 Installation & Operation MN1800 LSE Stage Connector Locations Home Limit LD9123A00 LD9125A02 LD9124A00 LD9125A01 Limit.
Installation & Operation 2-21 MN1800 LSC Series Cross Roller Position Stage General Description: Single axis linear stage with linear motor , linear bearings, linear encoder , limit switches, cabl.
2-22 Installation & Operation MN1800 A Y1775A00 Leadwire Connection for LinDrive 15 pin Color Pin# Description Green 1 A+ Blue 2 B+ Pink 3 C+ White 4 Hall1 5 N/C Y ellow 6 A – Red 7 B – Gray 8 C – Black 9 Hall3 Red 10 Hall2 Brown 1 1 +5VDC 12 N/C White 13 Encoder GND (Halls Brown) 14 15 Outer shield to shell.
Installation & Operation 2-23 MN1800 Leadwire Connection Limit Switch Pigtails 671P OUT L 1 2 3 4 1 2 3 4 671P OUT L 671P OUT L Home H – Limit Limit Color Pin# Description Brown 1 Limit & Ho.
2-24 Installation & Operation MN1800 LSS Series Single Bearing Position Stage General Description: Single axis linear stage with cog – free linear motor , linear bearings, optical linear encoder , limit switches, cable carrier and bellows Construction: Magnet assembly/stage base is hard chrome plated steel.
Installation & Operation 2-25 MN1800 A Y1801A00 Stages with Renishaw Encoder (RGH22) Flying Leads Cable 1 (Hall Cable) Cable 2 (Motor Cable) Cable 4 (RGH22 Encoder Cable) Cable 3 Limit Cable (opti.
2-26 Installation & Operation MN1800 LSX Series Single Bearing Position Stage General Description: Single axis linear stage with linear motor , linear bearings, magnetic encoder , limit switches, .
Installation & Operation 2-27 MN1800 A Y1682A00 LSX Stage Endplate Internal Connections * Limit & Home power is +4 to +24VDC. A B C D E F G H J K L M N P R S T U V 19 Pin Circular Connector (M.
2-28 Installation & Operation MN1800 LD9102A00 LSX Motor/Limit Cable Connections (19 pin to flying leads) * Limit & Home power is +4 to +24VDC.
Installation & Operation 2-29 MN1800 LSX Leadwire Connection Limit Switch Pigtails 670P OUT L 1 2 3 4 1 2 3 4 Limit Color Pin# Description Brown 1 Limit & Home power * 2 N/C White 3 Limit Outp.
2-30 Installation & Operation MN1800 A Y1743A00 LSX Internal Encoder/Hall Cable (15 pin to 8 pin and 6 pin) Color Pin# Description Green 1 A+ Blue 2 B+ Pink 3 C+ White 4 Hall1 5 N/C Y ellow 6 A .
Installation & Operation 2-31 MN1800 Bearing Maintenance Recirculating Bearing Rail And Block Lubrication type: For grease lubrication, a lithium – soap base grease (consistency No. 2 of JIS) is most frequently used. For linear guides operating under a heavy load, a grease containing extreme pressure additive is recommended.
2-32 Installation & Operation MN1800 Encoder Maintenance RSF Series MSA6x Enclosed T ype T echnical Data: Linear encoders measure the position of linear axis without mechanical translation components. This reduces the potential error due to thermal behavior of the linear motor and backlash from mechanical translation.
Installation & Operation 2-33 MN1800 RSF Series MS6x Open T ype Glass Scale Encoder type: Non contact optical, glass scale, open type. Open scale linear encoders are used primarily where environmental conditions are clean, dry and free of oils.
2-34 Installation & Operation MN1800 Renishaw RGH22 series Open T ype Metal Scale Encoder type: Non contact optical, metal scale, open type. Open scale linear encoders are used primarily where environmental conditions are clean, dry and free of oils.
Installation & Operation 2-35 MN1800 Renishaw RGH22 series Open T ype Metal Scale Continued Specifications: DC Power: 5VDC @ 120mA Output Signal: Square wave dif ferential line driver to EIA RS422 (except limit switch Q and external set – up signal X).
2-36 Installation & Operation MN1800 ELGO Mix 4 series Magnetic T ype Encoder type: Non contact, magnetic, open type. Open scale linear encoders are used primarily where environmental conditions are clean, dry and free of oils. The magnetic encoder scale is susceptible to damage from magnetic fields.
Installation & Operation 2-37 MN1800 Mix 4 and Mix 5 Dial Settings Dial Setting Resolution (using 4x multiplier) 1000 1000 µ m/pulse (1mm) Note: These resolutions are only available with 4 edge counting mode. 500 500 µ m/pulse (0.5mm) 100 100 µ m/pulse (0.
2-38 Installation & Operation MN1800 Encoder Head Output Connector Pin Assignment ML6040A00 Cable Color Pin# Description Black 1 Encoder GND White 2 +5VDC Green 3 Encoder A+ Pink 4 Encoder B+ Brow.
Installation & Operation 2-39 MN1800 Cables and Cable Chain Procedures If your positioning stage is supplied with a cable chain, follow these recommendations regarding its use: S Y our stage is supplied with high flex cables that are designed to withstand millions of bend cycles.
2-40 Installation & Operation MN1800 Additional Cables LD91 10A00 LinDrive External Encoder Output X7 Leadwire Connection (9 pin to flying leads) 1 2 3 4 5 6 7 8 9 Male (D Sub) Color Pin# Description Green 1 A+ Pink 2 B+ Brown 3 C+ 4 N.C. Black 5 DGND Y ellow 6 A – Red 7 B – Gray 8 C – 9 N.
BALDOR ELECTRIC COMP ANY P .O. Box 2400 Ft. Smith, AR 72902–2400 (501) 646–471 1 Fax (501) 648–5792 Baldor Electric Company MN1800 Printed in USA 1/01 C&J1500 CH TEL: +41 52 647 4700 F A.
Een belangrijk punt na aankoop van elk apparaat Baldor iMN1800 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Baldor iMN1800 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Baldor iMN1800 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Baldor iMN1800 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Baldor iMN1800 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Baldor iMN1800 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Baldor iMN1800 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Baldor iMN1800 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.