Gebruiksaanwijzing /service van het product 1000 van de fabrikant SPX Cooling Technologies
Ga naar pagina of 12
/ Mar le y Sigma 1 0 0 0/120 0 Cooling T ower /.
2 Y ou’ll enjoy single source r esponsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system.
3 / Sigma Adv antag e / • GuaranteedPerformance. Don’t r ely on outside agencies with limited enforcement powers. W e’ll stand by our responsibility for r eliable thermal performance. We designed it. W e rate it. We guarantee it! • Exclusive5-Y earMechanicalW arranty .
4 / Constr uction and Components / Fill/Louvers/Drift Eliminators Marley high-performance film fill is the heart of every Sigma tower . A repeating chevr on pattern provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airflow so you’ll save on fan power .
5 fans, used on larger models, include hollow GRE (glass- reinfor ced epoxy) blades and epoxy-coated cast iron hubs. Blades on both fan types are adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual job site restrictions.
6 W ater Distribution System The gravity-flow water distribution system designed into the Sigma tower essentially reduces pump head to its most basic component – static lift – saving you money on pump power . Y ou won’t have to for ce water through internal piping and pressur e spray nozzles, as you would in a counterflow tower .
7 The 4" x" 4 tower diagonals carry loads to heavy- duty hot-dip galvanized steel anchor plates or hot-dip galvanized anchor weldments. The system of longitudinal and transverse diagonal bracing provides stability in a true tension-compression design.
8 / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Plywood Cold W ater Collection Basin Pressur e-treated Douglas fir plywood collection basin for towers located above grade. See page 11. Bottom-Outlet Sump Square-plan galvanized steel sump with bottom outlet.
9 Cell Partition Options Every Sigma tower includes plenum chamber partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions ensure consistent thermal performance as you shut off one fan at a time.
10 Fire Pr otection Options The PVC fill, louvers and drift eliminators used on Sigma towers are fir e-retar dant, having flame spread ratings less than 25 per ASTM E-84. Standard fan decking material is pressur e-treated fir plywood which ignites poorly and burns slowly .
11 Cold W ater Collection Basins If you plan to locate your tower above grade, a treated Douglas fir Marley cold water collection basin is available, complete with the necessary operating accessories. The basin floor is exterior grade, pressur e-treated fir plywood, supported on joists.
/ Additional Services / SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project.
Een belangrijk punt na aankoop van elk apparaat SPX Cooling Technologies 1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen SPX Cooling Technologies 1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens SPX Cooling Technologies 1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding SPX Cooling Technologies 1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over SPX Cooling Technologies 1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van SPX Cooling Technologies 1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de SPX Cooling Technologies 1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met SPX Cooling Technologies 1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.