Gebruiksaanwijzing /service van het product DS41 van de fabrikant Standard Horizon
Ga naar pagina of 17
DS41 Digital Depth Sounder Owner’ s Manual Standard 2 Inch Installation Dual Station Operation NMEA Repeater Reads in Feet Fathoms or Meters Adjustable Prop or Surface Offset Shallow and Deep alarms.
DS41 Owner’s Manual DS41 Owner’s Manual DS41/HS/2G Contents Specifications ................................................................................................................. 2 Operation ..............................................
DS41 Owner’s Manual 2 Specifications • Size Mount 2" (51mm) diameter hole Depth behind face plate 3.75" (95mm) max. Display 3-character LCD • Color Black with texture on bezel. • Backlighting Red colored diffused lighting for displa y .
DS41 Owner’s Manual 3 Operation Whenever power is applied the depth sounder is active and water depth is displayed. If the sonar signal does not show a bottom the display will indicate “- -”. This can occur if the water is aerated or the maximum depth is exceeded.
DS41 Owner ’ s Manual 4 Deep Alarm T o set the deep alar m: 1. Press the # ke y for three seconds. The display will show: dAL OFF OFF ON ^ V V 2. After two seconds the display will indicate the current Deep Alarm depth setting. 8 8 50 3. Use the " and # keys to change the value.
DS41 Owner ’ s Manual 5 4. Use the " and # keys to change the value. If either key is held depressed for more than one second the reading will increase or decrease rapidly . 5. The offset can be programmed in 0.1 unit steps from -9.9 ! 9.9 feet (or equivalent).
DS41 Owner ’ s Manual 6 T roubleshooting No display: 1. Check DC po wer connections and DC polar ity with voltmeter . 2. Check fuse. No depth reading ( ## ## ## ## ## ) at all depths: 1. Check transducer for growth or multiple coats of paint. 2. Check the transducer cable for cuts and sharp bends.
DS41 Owner ’ s Manual 7 What comes with your Digital Depth Sounder Standard Mounting Bracket ................................................................. With mounting hardware Extension P ower Cord ......................... 6 feet long with quick-disconnect connectors T wist Lock F ace Plate .
DS41 Owner ’ s Manual 8 2.75" 2.125" 13 ° Note: All transducers come with 30 feet of cable. Replacement Parts The follo wing par ts may be ordered from the P ar ts Depar tment. T o order , call T oll-free Number: 1-800-487-2788. Square F ace Plate .
DS41 Owner ’ s Manual 9 Installation Face Plate Installation 1. T o install a face plate: a ) Attach the face plate to the front panel of the instrument. b ) T wist the face plate cloc kwise until tight. 2. T o remov e f ace plate, twist it anticlockwise until loose and detach.
DS41 Owner ’ s Manual 10 6. Connect the power cord at the back of the instrument to a 12 V power supply which is active whenever the ignition switch is on. The red lead should be connected to the positive terminal of the power supply via a 1 amp fuse or a 1 amp circuit breaker .
DS41 Owner ’ s Manual 11 T ransducer Installation Note: The installation of a transducer is a job for a professional boat yard that performs numerous installations. The following is an informational guide- line on the installation of transducers. General Correct installation of the transducer is essential for optimum operation of the instrument.
DS41 Owner ’ s Manual 12 Sailboats On sailboats, the transducer should be mounted where the acoustic beam will not be shaded by the keel. A spot forward of the keel is usually best. T ry to find an accessible spot with a minimum deadrise angle. See Figure 4.
DS41 Owner ’ s Manual 13 RUBBER GROMMET SEAL CAP OIL DEADRISE ANGLE CUT PVC PIPE TRANSDUCER Figure 7. In-Hull Installation In-Hull Installation T ransducer installation inside a solid fiberglass hull ma y degrade perf or mance of depth sounder. Therefore, this type of installation is not preferred over thru-hull and transom installations.
DS41 Owner ’ s Manual 14 Multiple DS41 instruments can be installed on a single vessel. These instr uments can be connected together and configured to operate in a dual station configuration. One instrument is designated as a master and all other instruments, connected to it, are configured as slav es.
DS41 Owner ’ s Manual 15 4. Continue to hold the # key until the display indicates the current linked/ separate selection. Linked Separate 5. Use the " and # keys to change the selection. 6. T o exit this mode , press and hold both the " and # k eys sim ultaneously .
DS41 Owner ’ s Manual 16 The DS41 can be configured to operate as a NMEA repeater . In this mode it will display depth information from any depth sounder outputing DPT or DBT NMEA depth data (no other NMEA depth sentences are supported). Notes: 1 ) The only information displayed from the DPT and DBT sentence is depth below the transducer .
Een belangrijk punt na aankoop van elk apparaat Standard Horizon DS41 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Standard Horizon DS41 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Standard Horizon DS41 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Standard Horizon DS41 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Standard Horizon DS41 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Standard Horizon DS41 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Standard Horizon DS41 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Standard Horizon DS41 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.