Gebruiksaanwijzing /service van het product 184748-001 van de fabrikant State Water Heaters
Ga naar pagina of 24
1 PRINTED IN THE U.S.A. 1004 P ART NO. 184748-001 supersedes 184748-000 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHEN EVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED T O THE LOCAL DEALER FROM WHOM THE W A TER HEA TER WAS PURCHASED.
2 SAFE INST ALLA TION , USE AND SERVICE Y our safety and the safety of others is extremely import ant in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
3 GENERAL SAFETY.
4 Thank Y ou for purchasing this water heater . Properly inst alled and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • ANSI - America.
5 TYPICAL INST ALLA TION FIGURE 1. INST ALL V ACUUM RELIEF IN COLD W A TER INLET LINE AS REQUIRED BY LOCAL CODES. INST ALL SUIT ABLE DRAIN PAN S UNDER HEA TERS TO PREVENT DAMAGE DUE TO LEAKAGE. REFER TO W A TER HEA TER LOCA TION ON P AGE 8. INST ALL THERMAL EXPANSION T ANK OR DEVICE IF W A TER HEA TER IS INST ALLED IN A CLOSED W A TER SYSTEM.
6 MIXING VAL VE USAGE FIGURE 2. W ater (Pot able) Heating: All models are considered suitable for water (potable) heating only . HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water.
7 Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor .
8 The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion.
9 The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Relief V alves and Automatic Gas Shut-off Devices for Hot Water Supply Systems, ANSI Z21.
10 T o fill the water heater with water: 1. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater . 2. Open the cold water supply valve to the water heater . NOTE: The cold water supply valve must be left open when the water heater is in use.
11 WIRING DIAGRAMS TURN OFF THE HEA TER ELECTRICAL SUPPL Y BEFORE SERVICING ANY ELECTRICAL COMPONENTS. FIGURE 7..
12 WIRING Never use water heater unless it is completely full of water . T o prevent damage to the tank and heating element, the tank must be filled with water . Water must flow from the hot water faucet before turning on power . Y ou must provide all wiring of the proper size outside of the water heater .
13 TEMPERA TURE ADJUSTMENT T o change the temperature setting: NOTE: It is not necessary to adjust the upper thermostat. However , if it is adjusted above the factory set point (120°F (49°C)/HOT) it is recommended that it not be set higher than the lower thermostat setting.
14 THERMAL EXP ANSION W ater supply systems may , because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc.
15 If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater , follow the draining instructions, and replace the temperature-pressure relief valve with a new one.
16 1 . Turn “OFF” the electric power supply to the water heater . 2 . Remove the outer door , insulation block and pad in the order they are installed. 3. A . Models with lower thermostat without high limit: Lift out the tab as shown below to unclip the terminal cover from the thermostat.
17 The water passing out of the drain valve may be extremely hot. T o avoid scalding, make sure all connections are tight and that the water flow is directed away from any person. 4 . Remove the two screws securing the outer door , and remove door . FIGURE 15.
18 1 1. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater . 1 2 . Open the cold water supply valve to the water heater . NOTE: The cold water supply valve must be left open when the water heater is in use.
19 LEAKAGE CHECKPOINTS Read this manual first. Then before checking the water heater make sure the electrical power supply has been turned “OFF” before checking the tank for leakage. *A. Condensation and dripping may be seen on pipes if the water temperature is low in humid weather or pipe connections may be leaking.
20 These guidelines should be utilized by a qualified service agent. TROUBLESHOOTING GUIDELINES Improperly sealed, hot or cold supply connection, relief valve or drain valve. Leakage from other appliances or water lines. Thermal expansion in closed water system.
21 REP AIR P ARTS LIST WHEN ORDERING REP AIR P ARTS, AL W A YS GIVE THE FOLLOWING INFORMA TION: • MODEL NUMBER • SERIAL NUMBER • VOL T AGE AND ELEMENT W A TT AGE • P AR T DESCRIPTION THIS IS A REP AIR P ARTS LIST , NOT A P ACKING LIST .
22 NOTES.
23 NOTES.
24.
Een belangrijk punt na aankoop van elk apparaat State Water Heaters 184748-001 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen State Water Heaters 184748-001 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens State Water Heaters 184748-001 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding State Water Heaters 184748-001 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over State Water Heaters 184748-001 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van State Water Heaters 184748-001 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de State Water Heaters 184748-001 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met State Water Heaters 184748-001 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.