Gebruiksaanwijzing /service van het product Residential Gas Water Heater van de fabrikant State Water Heaters
Ga naar pagina of 32
1 Instruction Manual PRINTED IN THE U .S .A 09 05 P AR T NO. 185244-001 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
3 GENERAL SAFETY.
4 SAFE INST ALLA TION, USE AND SER VICE ............................... 2 GENERAL SAFETY .................................................................. 3 T ABLE OF CONTENTS .............................................................. 4 INTRODUCTION .
5 TYPICAL INST ALLA TION GET T O KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe–Exhaust B V ent T erminal C V ent Adapter-Rubber Boot D Blower Assembly E Cold Water Inlet F Inlet Water Shut-off V alve G Union H Inlet Dip T ube J Anode** FIGURE 1.
6 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE USAGE This appliance has been design certified as complying with American National S tandard/CSA S tandard for water heaters and is considered suitable for: W ater (Potable) Heating and S pace Heating: All models are considered suitable for water (potable) heating and space heating.
7 FACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
8 and 12" (30.5 cm) from the top. (S tandard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater . Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc.
9 Chemical vapor corrosion of the flue, blower assembly and vent system may occur if air for combustion contains certain chemical vapors. S pray can propellant s, cleaning solvents, refrigerator and a.
10 The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion.
11 Figure 10 shows the typical attachment of the water piping to the water heater . The water heater is equipped with 3/4 inch NPT water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection.
12 GAS PIPING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5 kPa) for natural and propane gas (L.P .). The minimum inlet gas pressure shown on the rating plate is that which will permit firing at rated input.
13 SEDIMENT TRAPS A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap.
14 VENT CONNECTIONS TO BLOWER ASSEMBL Y Figure 15 shows the optimal placement of the 2" to 3" or 3" to 4" reducer; however , the vent can be reduced at any point in the vent system as long as the maximum and minimum vent length requirements are met.
15 The unit may be vented horizontally through a wall or vertically through the roof. Pipe runs must be adequately supported along both vertical and horizontal runs as follows: • For Schedule 40, 2" PVC, ABS, Coex Cellular Core vent pipe: Every 3 feet (0.
16 For 4" V enting, the maximum equivalent feet of pipe allowed is 160 feet (48.8 m). This does not include the V ent T ermination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2.
17 FIGURE 16. This unit can vent through 2", 3" or 4" nonmetallic pipe and fittings. The vent pipe installation can be started from either the blower discharge or the termination wall. Keep in mind the total vent system (pipe and elbows) when installing the vent system, see VENTING AND INST ALLA TION, pages 14 - 16.
18 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specific application you are attempting. B . Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use.
19 B . Deburring Use a knife, plastic pipe deburring tool, or file to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°- 15° should be added to the end to permit easier insertion of the pipe into the end of the fitting.
20 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner .
21 Due to the nature of the typical gas water heater , the water temperature in certain situations may vary up to 30°F (16.7°C) higher or lower at the point of use such as, bathtubs, showers, sink, etc. Any water heater’s intended purpose is to heat water.
22 FOR YOUR INFORMA TION ST ART UP CONDITIONS CONDENSA TE Whenever the water heater is filled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when: a .
23 VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1. Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed. 2 . Damage or deterioration which could cause improper venting or leakage of combustion products.
24 INST ALLED IN SUIT ABLE AREA: T o insure suf ficient ventilation and combustion air supply , proper clearances from the water heater must be maintained. See “Locating the New Water Heater” section. Combustible materials such as clothing, cleaning materials, or flammable liquids, etc.
25 LEAKAGE CHECKPOINTS Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely filled with water .
26 Key No. Part Description 1 Burner Assembly 2 Burner Head 3 Burner Orifice 4 Burner T ube 5 HSI Ignition Assembly 6 Inner Door 7 Inner Door Gasket 8 Flue Baffle 9 Flue Restrictor 1 0 Blower Assembly.
27 TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualified service technicia n. Read the GENERAL SAFETY INFORMA TION section first.
28 These guidelines should be utilized by a qualified service agent. When calling for service notify the service agent that this is a “Flammable V apor Ignition Resistant” Product.
29 NOTES:.
30 NOTES:.
31 THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY . If the glass lined tank in this water heater shall prove upon examination by (the warrantor) to have leaked during the warranty period in no.
32 500 T ennessee Waltz Parkway Ashland City , TN 37015 www.statewaterheaters.com.
Een belangrijk punt na aankoop van elk apparaat State Water Heaters Residential Gas Water Heater (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen State Water Heaters Residential Gas Water Heater heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens State Water Heaters Residential Gas Water Heater vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding State Water Heaters Residential Gas Water Heater leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over State Water Heaters Residential Gas Water Heater krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van State Water Heaters Residential Gas Water Heater bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de State Water Heaters Residential Gas Water Heater kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met State Water Heaters Residential Gas Water Heater . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.