Gebruiksaanwijzing /service van het product BF3-600 van de fabrikant Sterling
Ga naar pagina of 67
Digital Dosing Units 1 SDD Digital Dosing Units Part Number: 882.00276.00 Bulletin Number: BF3-600 Effective: 12/01/05 Write Down Your Serial Numbers Here For Future Reference: _______________________.
Please note that our address and phone infor mation has changed. Please reference this page for updated contact information . These manuals are obsolet e and are provided only for their techni cal informat ion, data and capacities.
Digital Dosing Units 2 Table of Contents SECTION 1: INTRODUCTI ON …………….…………… ………….………...3 1.1 Controller . .............................................................................................................
Digital Dosing Units 3 Section 1: Introduction This User’s Manual is intended for use with th e Digital Dosing Additive Feeder. The feeder precisely meters and controls the addition of mast er batches, chemical additives, and r egrinds to primary plastics.
Digital Dosing Units 4 Figure 2. 2 Station Digital Dosing Unit Q U I C K S T A R T P A G E S H A V E B L U E B O R D E R.
Digital Dosing Units 5 1.1 Contr oller The Digital Dosing additive feeder consists of a controller, dosi ng m otor, and feeder(s). The controller is used to • Enter, recall, and run recipes • To r.
Digital Dosing Units 6 1.2 Keys and Symbols Recipe Storage/Recall: For saving, recalling or modifying recipes. Stop : Stops the continuous operation of the feeder. W ill reset the totalizer showing metered amount of additive to zero if depressed f or two seconds.
Digital Dosing Units 7 Symbols Lights when the run signal from the pro cess machine is rece ived by the Digital Dosing controller. During operation, lights when the disc is dosing material. During calibration and recipe input/viewing, lights when a ca libration weight is input or viewed.
Digital Dosing Units 8 Section 2: Quick Start-up Quick Start is intended to help you in startin g up your Digital Dosing feeder quickly and easily. Please refer to the manual to go into gre ater detail. Unpacking: 1. Unpack box, making sure all parts indi cated on packing list are included.
Digital Dosing Units 9 3. Press Input to display #2, “Shot size of current mold”. Using arrow keys, set the total shot size (parts and runners) of the current mold capacity in gram s. 4. Press Input to display #3, “Screw recovery time”. Using arrow keys, set the screw recovery time (in seconds).
Digital Dosing Units 10 6. Repeat step #19 four more times, each time en tering the new weight from the scale into the controller using the arrow keys. Sometim es the values w on’t change, or sometimes they may only change by a few tenths of a gram.
Digital Dosing Units 11 Section 3: Initial Installation And Operation 3.1 Initial Installation Direction of Material Flow Hopper Piece Processing Machine Figure 4.
Digital Dosing Units 12 be exposed to extreme heat (maxim um temperature 45 ° C or 115 ° F) or excessive moisture. 4. Electrical connection to process machine: • Injection Molding : Connect the cycle/run slave ca ble (thin two-conductor cable) to a set of DRY (NO VOLTAGE) contacts that CLOSE for the duration of screw recovery.
Digital Dosing Units 13 NOTE: Zero input corresponds to zero scre w speed and no additive dosing. Maximum input corresponds to maximum screw speed. NOTE: If a 0-10kHz frequency input is used, it must be a square wave with an amplitude of 12VDC. The shape of the signal is important, especially above 7,000Hz.
Digital Dosing Units 14 • Recipe parameters are different for Injection Molding, Extrusion-Constant, and Extrusion-Proportional operation. See each ind ividual section for details. • The calibration method is the sa me for all processes. • Once the unit is online, the user may want to save recipes for later reca ll (10 maximum).
Digital Dosing Units 15 • Enter the additive perc entage by using the Arrow Keys . (The range of values that can be entered is 0.01% to 50.00%. The arrow keys are used to change all process variables. The d ouble arrow key allows the user to ramp up or down by larger increments.
Digital Dosing Units 16 this value during operation. The range of va lues that can be entered in this field is 00.50 to 99.99 seconds. Step 4: • Press Input a fourth time. • The symbols “ g ” or “ lb ”and flash. • After “4” quickly flashes on the screen, a number in the format xxxx.
Digital Dosing Units 17 • After “5” flashes on the display, a numb er in the format xxx.xx will come up on the display. • Enter the maintained running time of the blending unit in seconds using the arrow keys. This is how long the blende r will run after each dosing cycle and should be adjusted for the best possi ble blend.
Digital Dosing Units 18 1. Pressing again will first display th e number “18” and then will display the total throughput in kilograms (totalizer). Operation-Injection Molding 1. Ensure that the unit is properly installed (Section 3.1), a recipe is entered (section 3.
Digital Dosing Units 19 light on the controller during screw recovery. The disc symbol will light when the Digital Dosing unit is dosing material. • The totalizer will in crease after each cycle by th e amount of material dosed. • To stop the dosing process, press .
Digital Dosing Units 20 • Press once. • The symbol will flas h. • After “1” flashes on the screen, a number in the format xxx.xx will come up on the display. • Enter the additive perc entage by using the Arrow Keys . The range of values that can be entered is 0.
Digital Dosing Units 21 • Press a third time. • The machine displays a flashing , “g” or “lb” and a number “4”flashes on the display (because this is Extrusion Constant, step 3 is skipped). • After the “4” flashes on the display, a number in the form at xxxx.
Digital Dosing Units 22 Step 5: 6. Press again. 7. The number “18” will be display ed before the total throughpu t in kg is displayed. Operation –Extrusion Constant 1. Ensure that the unit is properly installe d (Section 3.1), a recipe is entered (Section 3.
Digital Dosing Units 23 NOTE: See Appendix A, Troubleshootin g, for information on problems or errors encountered and their resolution . 3.5 Extrusion Pr oportional Recipe Input – Extrusion Proporti.
Digital Dosing Units 24 Step 2: • Press again. • The machine displays a flashing “ g ” or “ lb ”, a flashing “ min ” and . • After “2” flashes quickly on the display, a number in the format xxx.
Digital Dosing Units 25 Step 4: 1. Press a fourth time. 2. The machine displays a flashing and “ g ”. 3. After “4” flashes quickly on the screen, a number in the form at xxx.xx will come up on the display. • Enter the calibration weight in grams or pounds.
Digital Dosing Units 26 2. Place the Digital Dosing unit into op eration by pressing the Run key ( ). The green LED will light when the unit is ready to dose, but will not feed until the extruder begins operation. 3. Start the extruder. The Di gital Dosing unit will begin dosing material as soon as the extruder starts.
Digital Dosing Units 27 Determining the Calibration Weight Step 1: • To start the calibration proce ss, press the calibration key. Step 2: • Once the sample container is in position, press . • The disc will rotate 1/4 revolution an d dispense material in to the sample container.
Digital Dosing Units 28 • The disc will rotate one full revolution. After the disc has stopped rotating, a number in the format “xx.xx” will ap pear on the screen along with a flashing and “ g .
Digital Dosing Units 29 • Pressing the stop button will stop pro portioning a nd not accept the calibration weight. • Pressing the calibration button will stop proportioning and accept the calibration weight. NOTE: It is normal for calibration weights to vary slightly from sa mple to sample.
Digital Dosing Units 30 Section 4: Advanced Operations/ Control Functions 4.1 Recipe S torage And Recall A maximum of ten (10) recipes can be stored and retrieved with the Digital Dosing controller in the Recipe Storage/Recall mode. Recipes are st o red using a two-digit identification number.
Digital Dosing Units 31 • Press and hold the button until the totalizer display returns to the screen. • The recipe is now stored under the selected ID number. Recipe Recall Step 1: • Press the stop button to st op any current applications. Step 2: • Press the Storage/Recall key ( ) once.
Digital Dosing Units 32 • Press and hold until the totalizer ap pears on the screen. • The recipe is now active and can be run or edited. NOTE: The recalled recipe now becomes the active recipe. 4.2 Clearing The T otalizer • The totalizer displays the tota l amount of additiv e dosed since the last time the totalizer was cleared.
Digital Dosing Units 33 Alarms Several alarm options are available for the Digita l Dosing feeder. The standard unit comes with a flashing alarm symbol on the faceplate. Options includ e both audible horns and flashing lights. An optional no voltage alar m relay can be connected to the user’s central alarm system.
Digital Dosing Units 34 Mixer An optional mixer is available that can be mount ed under the Digital Dosing unit. The m ixer is used to help distribute fine pow ders and granules. During the injection molding process, the mixer only runs during screw recovery (when th e Digital Dosing unit is dosing additives).
Digital Dosing Units 35 Figure Section 5: Maintenance 5.1 Maintenance Intervals Daily: Check warning signs on equipment for good legibility and completeness. Weekly: Check function of the on/off Switch. Every 3 months: Check scraper in dosing station DD/DT.
Digital Dosing Units 36 6. Remove the dosing unit from the dosing motor. 7. Remove the cover from the connectin g piece (D). 8. Loosen the two screws (C) on the unde rside of the dosing unit housing (E). 9. Remove the scraper (A). Installing the scraper 1.
Digital Dosing Units 37 5. Remove the dosing hopper from the dosing unit. 6. Dismantle the dosing unit and rem ove the scraper (D). 7. Loosen the two hexagon socket screws (B, M6 x 30) on the top side of the dosing disc (A). 8. Loosen the center hexagon socket screw (C, M6 x 12) and replace by an M6 x 60 screw.
Digital Dosing Units 38 5.4 Changing the Dosing Disc in the Digital Dosing Dosing S tation Removing the Dosing Disc 1. Empty the dosing station. 2. Switch the control unit off by means of the on/off switch. 3. Dismantle the dosing unit a nd remove the scraper.
Digital Dosing Units 39 Installing Different Types of Dosing Discs Dosing discs of the same type may be exchange d for each other without any problem s. If dosing discs with a different compartment num ber are in stalled, this has to be entered in the control system! 1.
Digital Dosing Units 40 9. Install the dosing container along with th e dosing hopper on the dosing housing (pay attention to the guide pins). 10. Mount the profile clamp. 11. Mount the screw at the profile clamp. 5.6 Cleaning the DT Dosing S tation 1.
Digital Dosing Units 41 17. Install the dosing container along with th e dosing hopper on the dosing housing (pay attention to the guide pins). 18. Mount the profile clamp. 19. Mount the screw at the pr ofile clamp and tighten. 5.7 Exchangeable S tations Dosing discs of the same type may be exchange d for each other without any problem s.
Digital Dosing Units 42 6. Never try to repair a defective fuse. 7. Open the screws (A) and remove the lid (B). 8. Remove the blind lid (C) and open the screws. 9. Move the lid (D) aside. 10. Remove the defective fuse from the fuse carrier. 11. Install the new fuse (while obs erving the value).
Digital Dosing Units 43 Appendix A: Troubleshooting During setup and use of the Digital Dosi ng Additive Feeder, personnel may experience difficulties. Some of the problems encountered may be reso lved using the following techniques. A.1 General T roubleshooting - Unit W ill Not Operate • Check all connections and process wiring.
Digital Dosing Units 44 ERROR CODES Code Definition Possible Reason/Solution A001 Strap “safety switch” is missing. Manufacturer Service. A002 The nominal current of the dosing motor (=100%, see name plate) is being exceeded for more than 2 seconds by 30% or for a maximum of 0.
Digital Dosing Units 45 A.3 Determining the Softwar e Setup Factor The Digital Dosing control unit is configured via a Software Set up Factor (binary code). To determine the Software Setup Factor answer th e following questions: If th e answer is “yes” enter the code number in the selec tion colum n.
Digital Dosing Units 46 Disc RPM ( Additive - %) x (Total Extruder Throughput - lb / hr) 13.22 x (Disc Calibration Weight - g) = Recipe Limitations Extrusion Mot or Ass emb ly S pe ed ( RPM ) Max imu m Speed (RPM) 12 12.
Digital Dosing Units 47 Appendix B: Basic Parameter Settings Extrusion Mode: You need an extruder signal that is proportional to the extruder speed to operate in the Extrusion Proportional mode.
Digital Dosing Units 48 If a current signal is available (0 - 20 m A) calculate the frequency output of the extruder for the lower / upper working area using the formula: Frequency [Hz] = Input current [mA] x 10000 [Hz] 20 [mA] Note the data: Min. input frequency = __________ Hz Max.
Digital Dosing Units 49 Alarm output is switched in case of power failure . . . . . . . . . . . 512 ___ Extrusion mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024 ___ Printer available . . . . . . . . . . . .
Digital Dosing Units 50 Totalizer displayed in lb (kg defa ult) . . . . . . . . . . . . . . . . . . . . . . . . . 16 ___ Shotweight up to 6.5 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 or Shotweight 6.5 to 65 kg . . . .
Digital Dosing Units 51 Basic Parameter Settings.
Digital Dosing Units 52.
Digital Dosing Units 53.
54 Appendix C: Disc Dosing Factor s And Equipment Drawings And Parts Numbers Disc Dosing Factor Table 1: Disc Guide Disc Disc Nomenclature Used in the Controller Minimum/ Maximum Disc Revolution Weight Per Disc Revolution (Bulk Density 35lb/cuft) Min.
55 D30-051725 Default Calibration # 7.30 g/rev 051725 # of Hole s D iameter Disc Thi ckness 0.2 Rev./min 6.4 Rev. /min (6.4 RPM) 0.5 Rev./min 11.5 Rev./min (11.5 RPM) 1.0 Rev./min 35.5 Rev./min (35.5 RPM) 7.37 g/Rev. 0.30 g/Hole 0.20 lb/hr 0.09 kg/hr 0.
56 DT30-102025 Sure-Shot disc No Picture Default Calibration # 33.00 g/rev P102025 # of Hole s D iameter Disc Thi ckness 0.2 Rev./min 6.4Rev./min (6.4 RPM) 0.5 Rev./min 11.5 Rev./min (11.5 RPM) 1.0 Rev./min 35.5 Rev./min (35.5 RPM) 33.60 g/Rev. 1.3 g/Hole 0.
57 DP30 050940 Default Calibration # 15.00 g/rev P050940 # of Hole s Diam eter Disc Thi ckness 0.2 Rev./min 6.4Rev./min (6.4 RPM) 0.5 Rev./min 11.5 Rev./min (11.5 RPM) 1.0 Rev./min 35.5 Rev./min (35.5 RPM) 15.64 g/Rev. 0.39 g/Hole 0.41 lb/hr 0.187 kg/hr 1.
58 Specification Sheet DIGITAL DOSING UNIT TECHNICAL PARAMETERS Disc Dosing Factor Table 2 Maximum Number of Feed St ations One (1) for G ranule Processi ng Maximum Product Temperature 80 o C (or 176 o F) Weight (Approx imately) 20 kg (44 pounds) Connected Loads 0.
59 Digital Dosing unit parameter setup 7-14 Biso n - Black motor Bauer - Blue motor Comments Parameter RPM 2 6 12 38 6.4 11.5 35.5 7 650 00 25200 14103 4387 117 39 6600 2135 These values refer to the pulses of the encoder 8 0.
.
61 Station 1 Digital Dosing Unit SIDE VIEW TOP VIEW.
62 Station 2 Digital Dosing Unit SIDE VIEW TOP VIEW.
63 Dosing Unit Electrical Schematic Chart Drawing No. Description of Drawing Voltage CT102020 C150 CONTROLLER INJECTION 110 CT102021 C150 CONTROLLER EXT-S SIMPLE EXTRUSION 110 CT102022 C150 CONTROLLER.
64 Appendix D: Spare Parts List Dosing Disc/Shear Order Numbers Dosing disc 72 chambers ID 100562 49 chambers ID 21710 25 chambers ID 21711 18 chambers ID 2057 Dosing disc, wear-resistant 40 chambers .
65 - Notes-.
66 Technical Assistance Parts Department Call toll-free 7am–5pm CST [ 800 ] 423- 3183 or call [ 630 ] 595- 1060, Fax [630] 475-7005 The ACS Customer Service Group will prov ide your com pany with genuine OEM qualit y parts manufactured to engineerin g design specificatio ns, which will maximize your equipment’s performance and efficiency.
Een belangrijk punt na aankoop van elk apparaat Sterling BF3-600 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sterling BF3-600 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sterling BF3-600 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sterling BF3-600 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sterling BF3-600 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sterling BF3-600 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sterling BF3-600 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sterling BF3-600 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.