Gebruiksaanwijzing /service van het product K5960008-03 van de fabrikant Barco
Ga naar pagina of 61
DCMS Displa y Consistency Management Softw are User Manual K5960008-03.
2 _________________ ___________________ __________________ _____ Barco - DCMS - User Manual Intentionally left blank.
Barco - DCMS - User Manual _________________ ___________________ __________________ ____ 3 About 1A b o u t 1.1 Contents of the user manual This guide consists of the following c hapters: Chapter 1: A.
4 _________________ ___________________ __________________ _____ Barco - DCMS - User Manual About 1.3 Notation conv ention Foll owing notations are applicab le to this manual and should be respected through the manual.
Barco - DCMS - User Manual _________________ ___________________ __________________ ____ 5 Important notice 2 Important notice 2.1 Commercial In Confidence The information contained herein is Barc o confidential information.
6 _________________ ___________________ __________________ _____ Barco - DCMS - User Manual Important notice 2.6 Software License T erms 1 This Software License is betw een you and BARC O NV , a corporation organized and existing under the laws of Belgium regist ered under number BE 0473.
Barco - DCMS - User Manual _________________ ___________________ __________________ ____ 7 Important notice copies of the Softw are then in your possession and returning al l associated materials and d ocumentat ion, to Barco or the appo inted Barco reseller that sold or provided these to you.
8 _________________ ___________________ __________________ _____ Barco - DCMS - User Manual Important notice SUCH ERRORS WILL BE CORRECTED BY BARCO AND YOU ARE SOLEL Y RESPONSIBLE FOR ALL COSTS AN D EXPENSES ASSOCIA TED WITH RECTIFICA TION, REP AIR OR DAMAGE CAUSED BY SUCH ERRORS.
Barco - DCMS - User Manual _________________ ___________________ __________________ ____ 9 Important notice both parties. Excep t as otherwise expressly prov ided for in this Software License, no forb.
10 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual About DCMS 3A b o u t D C M S 3.1 What is DCMS? The Barco Display Consistency Mana gement So ft w ar e ( DC MS ) i s a so ft wa re to ol to calibr ate displays in terms of luminance, gamma and gr ay tracking*.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 11 About DCMS 3.3 K ey components 3.3.1 Calibr ation system Calibration with internal test pattern gener ation (without disconnecting the display from its source) The calibration can be done without disc onnecting the display .
12 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual About DCMS IMPORTANT : When calibr ation is done with external computer gra p hics, please restore all color.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 13 About DCMS 3.4 P ackage content • USB color sensor (Marked ‘Configured for DCMS’) • RS232 cable male-female, 3-wire str aight, 1.8m • RS232 cable male-female, 3-wire crossed, 1.
14 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Installing DCMS 4 Installing DCMS 4.1 System requirements • Host: Pentium II or later • Memory: 256MB .
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 15 Instal li ng DCMS •I n t r o d u c t i o n Read the introduction an d p r es s ‘ Next ’ to continue. It is strongly recommended to quit al l programs before conti nuing with the installation.
16 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Installing DCMS •E n t e r L i c e n s e K e y T o continue the installation, enter your pers onal License Key , supplied on the DCMS license certificate. Press ‘ Next ’ to continue.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 17 Instal li ng DCMS • Choose Shor tcut Folder Choose the location wher e the shortcuts will be located. There is a shortcut available for the DCMS application in the Barco DCMS program Group.
18 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Installing DCMS • Installing… During the installation, a dialog with progress bar is displayed. • Install Complete The Install Complete panel shows if the in stallation w as successful or not.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 19 Instal li ng DCMS 4.4 Uninstalling DCMS T o remove DCMS from your system: • Be s ure you have A dmin ist ra.
20 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Installing DCMS • Click the Uninstall button to remo v e the DCMS program. NOTE : Log files and files co ntaining calibr ation parameters are n ot automatically remove d.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 21 Connecting the components 5 Connecting the components 5.1 Optical sensor connection CAUTION : The USB sensor is deliv ered with a suction cup head that can be attached to the sensor for easy attachment to a displa y with front glass.
22 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Connecting the components • Select ‘No, not this time’ and click ‘Next’ to continue. • Select ‘Install the software automati cally’ and click ‘Next’ to continue.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 23 Connecting the components • Browse to the path where th e file ‘s eqcal.
24 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Connecting the components 5.2 Calibr a tion system connection Figure 4: Calibr ation system connection • Plug the sensor (delivered together with the DCMS software) in one of the USB connections of your PC.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 25 Connecting the components CAUTION : Barco displays ar e connected with a 3-w ire, crosse d or str aight serial cable. DCMS provides 2 serial cab les: one 3-wir e crossed ca ble and one 3- wire straight cable.
26 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application 6 Running the DCMS application 6.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 27 Running the DCMS application 6.1.2 Connection panel The user ca n select the display type an d display communication details in the Connection P anel.
28 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application Press the ‘Calibr a te Sensor’ button to start calibration.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 29 Running the DCMS application 6.1.4 Calibr ation target panel The Calibrati o n T arget Panel contains 8 sections. Eac h of these sections are listed and described below .
30 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application Note that the input source will not be vi sible for the dur ation of the calibration when the display pattern gener a tor is selected.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 31 Running the DCMS application Select the ‘Color temper ature’ radi o bu tton to define the white point in color temperature and use the slider to set the desired color temper ature between 3200 and 9900K.
32 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application The three input text fields ‘x’ , ‘y’ and ‘Y ’ are disabled as long as the check box ‘Fol low white point and gamma’ is sele cted.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 33 Running the DCMS application Figure 17: Gamma 4 Figure 18: Gamma 2 Figure 19: Gamma 1 The gamma slider can be used to set the desired gamma of the display . This value can also be seen in the text field on the right of the gam ma slider .
34 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application Get, Load, Save and Reset Besides u sing the contro ls above, the user h as the option to ‘Load’ a previously defined set of par ameters from file or ‘Save’ the current set to file.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 35 Running the DCMS application 6.2 Using DCMS 6.2.1 Proper use and gener al remarks • Store the sensor at the same ambien t tempe rature as the display , facing down in the sensor pod.
36 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application Calibration target panel ” par agr aph above. V erify that the sensor status field states ‘CALIBRA TED’ . Step 3: Calibration target • Select the type of test patches to be used.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 37 Running the DCMS application 6.2.3 Match displays In this section we will calibr ate a display (target display) to match another display (r eference display). The displays d o not need to be of the same type.
38 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application See the “User Interface, Sensor panel” paragr aph above for more details on the selection of the test patch.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 39 Running the DCMS application Step 7: The calibration routine • Press ‘Calibr ate now… ’ to open the calibr ation dialog. • Fol low the instructions as given in the calibration dialog and p r ess ‘Start’ to start the ca li b ration r out ine.
40 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Running the DCMS application Step 3: Measurement • Press the ‘Single measureme nt ’ button to open the measureme nt dialog. • Place the sensor on a color patch on the displa y to be measured and press ‘Measure’ .
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 41 Display connection and calibration options 7 Display connection and calibr ation options 7.1 ADP361 Connection The Barco ADP361 can be connected to the host by means of a 3-wire str aight (Rx-Rx, Tx - Tx, GND-GND) male-female cabl e.
42 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Display connection and calibration options 7.2 LCx -4x Connection The Barco LCx -4x series displays (LCN/ LCS-42/47) can be connected to the host by means of a 3-wire straight (Rx -Rx, Tx - Tx, GND-GND) male-female cable.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 43 Display connection and calibration options 7.3 MDP471 (ISIS) Connection The Barco MDP471 (code name ISIS) display can be connected to the host by means of a 3-wire crossed male-femal e cable (Rx - Tx, Tx-R x, GND-GND).
44 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Display connection and calibration options After calibration fo llowi n g dialog box pops up: Here you can choose whether th e calibrat ion v alue should be stored or not.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 45 Display connection and calibration options 7.4 MDPW476 Connection The Barco MDPW476 display can be connected t o the host by means of a 3-wire crossed male-female cable (Rx- Tx, Tx -Rx, GND-GND).
46 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Display connection and calibration options Figure 27: MDPW LUT selection The user can now select which of the 3 look -up-table slots the user wishes to overwrite with t he new calibr ation (slot 0 is reserved for a native 1-to-1 LUT).
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 47 Display connection and calibration options 7.5 NSL -4601 Connection The Barco NSL -4601 displa ys c an b e connec ted to the host by means of a 3-wire strai ght (Rx-Rx, Tx - Tx, GND-GND) male-female cabl e.
48 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Display connection and calibration options The monitor ID is the address of a monitor . The monitor address is a double (x, y) where x represents the horizontal position (column) and y the v ertical position (row) of the m onitor in the wall .
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 49 Display connection and calibration options Color versus brightness NOTE : Note that reducin g the color temper ature reduces the ov erall achiev able brightness.
50 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Calibration 8 Calibr ation Calibration is done in 3 major steps: Figure 31: Calibr ation steps flowchart Each of these step s is ex pl ai ne d in detail in the following sub p a ragraphs.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 51 Calibration Finally , we measure the luminance an d color of the maximum nativ e white. This is our starting point from where we calibrate to the required white point.
52 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Ve r i f i c a t i o n 9 V erification The verification table below lists an example output of a verification table.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 53 Ve r i f i c a t i o n The report shows: T able 3: V erification table expl anation.
54 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual The log file 10 The log file Each time th e DCMS applicat ion is starte d, a new log file is created. This file is named ‘dcmsxxx.log’ where xx x is the timestamp of creation.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 55 List of abbreviations 11 List of abbreviations A ADP Auxiliary Display Panel ALC Ambient Light Controller B B.
56 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual List of abbreviations SMPTE Society of Motion Picture and Television Engineers STD Standard SVGA Super Video.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 57 Appendix A: Open Source Softw are 12 Appendix A: Open Source Software DCMS copyright DCMS is copyrighted by Barco nv wi th exception of the RXTXComm libr ary . RXTXComm is open source software, licensed under the ‘RXTX extension to LGPL ’ .
58 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Appendix B: Specifcations 13 Appendix B: Specifcations 13.1 Specifications of the USB sensor • Connection type: USB • P ower supply: through USB.
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 59 T a ble of contents 14 T able of contents 1 About ......... .......................... .......................................... ................. 3 1.1 Contents of the user manual .
60 ________________ ___________________ __________________ _____ Barco - DCMS - User Manual Ta b l e o f c o n t e n t s 11 List of abbrevia tions ..................... ..................... ..................... ....... 55 12 Appendix A: Open Source Soft ware .
Barco - DCMS - User Manual _________________ ___________________ __________________ ___ 61 T a ble of contents End of document.
Een belangrijk punt na aankoop van elk apparaat Barco K5960008-03 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Barco K5960008-03 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Barco K5960008-03 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Barco K5960008-03 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Barco K5960008-03 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Barco K5960008-03 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Barco K5960008-03 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Barco K5960008-03 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.