STUDER INNOTEC TEL : ++41 (0)27 205 60 80 Rue des Casernes 57 FAX : ++41 (0)27 205 60 88 CH – 1950 Sion E-MAIL : info@studer-innotec.com User’s and installer’s Manual Sine wave Inverter, Battery.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 2/77 English description .................................................................................................................. 5 1 General Information .............................................
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 5/77 English description 1 General Information 1.1 Operating instructions This manual is part of the delivery pa ckage of every XP-COM PACT inverter-charger. It serves as guidelines for safe and e fficient operation of XP-COMPACT.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 6/77 − Damage from atmospheric over voltage (lightning) 1.4 Liability Disclaimer Respecting this manual, servicing and method of installation, functioning, application and maintenance of the appliance can not be controlled or supe rvised by STUDER INNOTEC.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 7/77 − Plenty of fresh water and soap must be ready at hand so that in case of acid coming in contact with skin, eyes and cl othes, the areas in question can be thoroughly washed. − If acid enters the eyes, you must thor oughly wash them with cold running water for at least 15 minutes.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 8/77 connection between Neutra l and earth in inverter mode only may be done by installing a bridge internally to the unit. Please contact your installer regarding this point. (2) Remote control for remote adjustment of the input limi t.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 9/77 2.3 Battery connecting Lead-acid batteries are normally available in blocks of 2V, 6V or 12V. In most cases, to generate the necessary operating voltage and the capacity of the batteries for the XP-COMPACT many batteries have to be c onnected together in parallel and or in series.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 10/77 3 Mounting and installing 3.1 Installation place The location of the XP-COMPACT must be driven by the following criteria: − Protection from unauthoriz.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 11/77 3.3.2 Protection cover of the terminals connections The protection is available as an option (Order ref. CFC-01) and avoid to do wrong hazardous connection on the termi nals 230Vac. It mounted with strain relief clamps for the cable.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 12/77 3.5 Cabling Connecting the XP-COMPACT is a very important step of t he installation. You must take care that all connection work is ca rried out in a clean and correct way and that under no circumstance a cable is connected to a wrong terminal.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 13/77 3.6.4 Connect the solar modules: SO LAR +/- (Only for solar option) Solar modules are connected on these termi nals. Under no circ umstances should any other energy source i.e. wind generator be connected to these terminals! Only solar modules must be connected with two cabl es +/-.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 14/77 4.2 Display and control parameters on remote control panel (optional) 4.3 Light Emitting Diodes (LED) LED Marking LED lit LED blinks 1 AC IN Voltage corresponding to self-adjusted values is at the AC IN input.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 15/77 10 Over Temp. For the time being the XP-COMPACT is out of service because of overheating. 11 Overload The XP-COMPACT is out of service because of overload or short- circuit 12 Batt. Low/High Battery voltage is too low Battery voltage is or was to high 13 OFF XP-COMPACT is turned off.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 16/77 4.6.1 Charge detection system „Standby“ In order to avoid unnecessary discharge of the battery, the inve rter switches OFF automatically if no appliance is connect ed and switches ON aut omatically again if appliance is connected.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 17/77 at the input (LED 1 AC IN is lit), the Ba ttery Charger is switc hed on automatically (LED 2 CHARGER is lit). The battery is fu lly automatically charged matching to the charge level, the adjusted vo lt-age levels and the charge current.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 18/77 Equalization mode should never be used when using Gel-Batteries. 4.7.4 Charging current The maximum charging current for the ba ttery can be adjusted with the Turning Knob 22 (CHARGER). The charging current of the battery should be set to approximately 10 – 20% of the battery capacity (at C10).
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 19/77 lit. The inverter is switched off and the batte ry charger switched on. This process is automatic, unless the charger mo de or the transfer mode is disabled (see Chap. 5.5). The maximum current of the Tr ansfer switch is 16A.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 20/77 4.9 The Solar charge controller (option) The XP-COMPACT also has a Solar Charge Controller built in. For charging the batteries, Solar modules can be connected to the screw terminal SOLAR +/-.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 21/77 4.11 The Remote Control RCC-01 As an option, a Remote Control can be connected to the XP-COMPACT. All operating controls and displays except from level adjustment are available on the Remote Control. The Remote Control is supplied with a 20m long cable.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 22/77 5 Programming (possible only wi th the remote control RCC-01) The XP-COMPACT (except for 60Hz versi ons) is equipped with a Flash processor fitted out w.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 23/77 With the Push Button 19 (Change status) se t the desired parameter (voltage or time) to modify (LED 14/ 15/16/17/18). Push Bu tton 19 (Change status) to set the desired value according to the table 5.3.2.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 24/77 are automatically stored and the XP- COMPACT switches back to normal operating condition. 5.4.3 Auxiliary Contact as generator starter As per the batter.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 25/77 The Auxiliary Contact can be operated at any time wit h the Push Button 21 (AUX. CONTACT). The LED 6 „Contact manual“ lights up as information that the Contact is manually operated, and LED 5 „Contact active “ lights up when the Contact is active.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 26/77 6 Installation Maintenance Apart from the periodic controls mentioned for the connections, the XP-COMPACT does need any maintenance. Keep the appliance clean and from time to time, wipe it clean with a damp cloth.
STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 27/77 8 Technical Data.
Een belangrijk punt na aankoop van elk apparaat Studer Cable Cover CFC-01 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Studer Cable Cover CFC-01 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Studer Cable Cover CFC-01 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Studer Cable Cover CFC-01 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Studer Cable Cover CFC-01 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Studer Cable Cover CFC-01 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Studer Cable Cover CFC-01 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Studer Cable Cover CFC-01 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.