NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903589 REV. E 02/2004 CFST -CMN CFPF-CMN CFST -CMP CFPF-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 GENERAL INFORMATION The CFST and CFPF Series Unvented Room Heaters covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating. These heaters have a standing pilot and are manually controlled through the use of a milli- volt gas valve.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING UNVENTED ROOM HEATER, VOIDING ITS WAR- RANTY.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Example: CFST/PF heater 34,000 BTU/Hr Gas appliance #1 32,000 BTU/Hr (water heater) Total = 66,000 BTU/Hr * Do not include direct-vent gas appliances. Direct-vent is sealed combustion and draws combustion air from the outdoors.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 41 ⁵⁄₈ ” (1210 mm) Figure 1 A hearth extension is not required with this appliance.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 CFST FRAMING SPECIFICATIONS CFST APPLIANCE SPECIFICATIONS A 22 ³⁄₄ " (578 mm)* B 43" (1092 mm) Min.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 6 Figure 7 Figure 8 C A B Gas Line CFPF FRAMING SPECIFICATIONS CFPF APPLIANCE SPECIFICATIONS Gas Line Energy Wall 2 x 4 Outside Wall Drywall Dr.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Step 2 . Route a ¹⁄₂ " (13 mm) gas line along the left or right side framing ( Figure 9 ). All appliances have a 3" long ³⁄₈ " NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Step 7. Installing the Optional Remote Wall Switch – The standard millivolt system comes from the factory wired as shown in Figure 12 . Select a convenient location for the remote wall switch and connect the wiring to the appliance ( Figure 13 ).
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VERMICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. Figure 15 Step 9. The heater includes a set of ceramic fiber logs.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The installation of the logs and twigs, should be complete and resemble Figures 15, 16 and 19 . After setting the logs and rockwool into posi- tion as described above, ensure the logs are properly and firmly situated.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Gas Flex Line with Valve A gas flex line kit is available to aid in attaching the appliance to the gas supply.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS Wall Switch Kit WSK Gas Flex Line Kit GFLV Decorative .
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 CFST REPLACEMENT PARTS LIST CFST GAS CONTROLS — MILLIVOLT CFST-CMN CFST-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123071 1 123072 1 2. Bar, Louver (Black) 104951 8 104951 8 3.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS – CFST 8 20 9 21 22 23 a. b. c. d. f. g. e. 3 2 1 7 6 2 11 4 5 10.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 CFPF REPLACEMENT PARTS LIST CFPF GAS CONTROLS — MILLIVOLT CFPF-CMN CFPF-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123073 1 123074 1 2. Bar, Louver (Black) - Main Panel 104951 8 104951 8 3.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 REPLACEMENT PARTS – CFPF 11 20 12 21 22 23 13 4 2 1 10 14 7 6 2 5 3 3 9 a. b. c. d. e. 8 f. g..
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 21 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 22.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 23.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 24 Printed in U.S.A. © 1997 by SFC P/N 903589 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited W arranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC.
Een belangrijk punt na aankoop van elk apparaat Superior CFST-CMP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Superior CFST-CMP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Superior CFST-CMP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Superior CFST-CMP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Superior CFST-CMP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Superior CFST-CMP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Superior CFST-CMP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Superior CFST-CMP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.