Gebruiksaanwijzing /service van het product SLDVT-30NM van de fabrikant Superior
Ga naar pagina of 40
MODELS I N S T A L L A T I O N I N S T R U C T I O N S SLDVT Direct-Vent Gas Fireplaces SLDVT -30NM SLDVT -30PM SLDVT -35NM SLDVT -35PM SLDVT -40NM SLDVT -40PM SLDVT -45NM SLDVT -45PM MILLIVOL T : SLDVT -30NE SLDVT -35NE SLDVT -40NE SLDVT -45NE ELECTRONIC: P/N 506009-01 Rev .
2 SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS T ABLE OF CONTENTS P a c k a g i n g .......................... 2 I n t r o d u c t i o n ........................ 2 General Information .
3 SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS W ARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injur y or property damage. Refer to this manual.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 2 - Dexen Electronic Gas Valve Pilot Stage T erminal Pressure-T ap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-T ap (Manifold) Bur.
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS Figure 3 - T ypica.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMIN.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS Figure 7 V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted = Air Supply Inlet X = Vent T ermination V D V 3 ft.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 ( 1 27 ) 8-1/4 ( 2 09 ) 14 ( 3 56 ) 12 ( 3 05 ) 19 ( 48 3) *Shelf Height ( see table) Do not insulate the space between the appliance and the area above it.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNING Fa il ur e to po si ti on th e pa rt s in ac co rd an ce wi th th es e d ia gr am s or fa il ur e to us e on ly pa rt s s pe ci fi- ca ll y ap pr ov ed wi th th is ap pl ia nce ma y re sul t in pr op ert y da mag e or pe rs on al i nj ury .
Ef fici enc ies (% ) Mo del N atu ral Ga s Pr opa ne AF UE En erG uid e ( P4) A FUE En erG uid e ( P4) SLDVT -30 57 51 5 8 54 SLDVT -35 59 59 6 1 61 SLDVT -40 62 61 6 4 61 SLDVT -45 64 59 6 6 61 10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FIREPLACE FRAMING SPECIFICA TIONS Figure 14 - Corner Framing with Horizontal T ermination Inches (millimeters) C Back wall of chase/enclosure (.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Installation of Vent Restrictor A vent restrictor may be needed with this appliance. The restrictor is installed in the appliance top flue outlet as shown in Figure 16 , either before adding vent, from above, or after installation of vent from below , within the firebox.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Push the vent component against the previous section until it fully engages, then twist the com ponent cloc kwise run ning the dimpl es down and along the incline channels until they seat at the end of the channels.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. If the vent system extends more than 5 feet (1.5m) above the roof ashing, stabilizers may be necessar y . Additional screws may be used at section joints for added stability . Guide wires may be attached to the joint for additional sup- port on multiple joint configurations.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. u Ce ili ng Fir est op / Sp ace r ( SV4 .5V F) u When using Se- cure Flex, use Firestop / Spac- er SF4.5VF A Vent Restrictor , as shown in Figure 16 Page 12 , must be used in this application Figure 25 - T op Vent - STRAIGHT u C ei li n g Fi re s t o p / S p ac er ( S V4 .
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintain a minimum 1" (25 mm) clearance to combustibles on the vertical sections. Clear - ances for the horizontal runs are; 3" (76 mm) on top, 1" (25 mm) on sides, and 1" (25 mm) at the bottom.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. S u p p o rt B r a c k et s B u i l d in g S u p p o rt F r a m i ng S V 4 . 5 E9 0 E l b o w C e i l i ng F i r e p la c e S V 4 . 5 L6 / 12 / 2 4/ 3 6/ 4 8 V en t S e c ti o ns V er t ic a l R i s e S u p p o rt Br a c ke t S p a ci n g E v e ry 5 ft ( 1.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS J. Assemble vent run to exterior wall - If not previously measured, locate the center of the vent at the exterior wall.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. See T able 8 as an aid in venting component selection for a particular range of exterior wall thicknesses. See T able 8 as an aid in venting component selection for a particular range of exterior wall thicknesses.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. V H H 1 Wall Firestop/Spacer (SV4.5HF) Wall Firestop/Spacer (SV4.5HF) Whe n using Sec ure Flex, use Firestop/Spacer SF4.5HF. Ceiling Firestop/Spacer (SV4.5VF) Note - When using Secure Flex TM , use Firestop/Spacer SF4.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Example: If 20 feet total (H+H 1 ) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required. This table shows a 1(V) to 5(H) ratio. For ever y 1 foot of (V) vertical, you are allowed 5 feet of (H+ H 1 ) horizontal run, up to a maximum horizontal run of 20 feet.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. D. I ns t al l F i r e s t op / S pa c er s a t c e il i ng s a n d w al l s - Whe n Secure Fle x pen etrat es a wa ll or ceili ng, a res top / spac er is requ ired: use the SF4 .5 VF re stop / spa cer fo r cei lings and the SF4.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS Step 4. FIELD WIRING B. Electronic Wiring (See Figure 38 ) – Note: The electronic appliance must be con- nected to the main power supply .
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS Note: Remote rece.
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Flex Line Gas Shut-Off Valve Valve Piezo Spring Door Latch Lower Control Compartment SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS Figure 41 Step 6.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T urn on gas supply and test for gas leaks, us- ing a gas leak test solution (also referred to as bubble leak solution).
28 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REFERENCE Firebox Accessories / Parts Cat. No. Mo d el No . Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Decorative Volcanic Stone Volcanic Stone 4. Placement of Glowing Embers - Separate the Embers (rockwool) into pieces about the size of a quarter (see Figure 46 ) .
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SLDVT -30 AND SLDVT -35 LOG PLACEMENT Figure 47 Step 2 Step 3 Step 4 3 Left Rear Brackets Step 1 Align hole at the bottom of left front log (1) over the left front brackets and the right front log over the right front brackets.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SLDVT -40 LOG PLACEMENT Step 2 Step 3 Step 1 4 2 Right Front Log "Nub" 3 Step 4 Log Number Description 1 Ember Chunk 2 Left Front Log.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SLDVT -45 LOG PLACEMENT Step 2 Step 3 Step 1 Step 4 Figure 49 Log Number Description 1 Left Front Log 2 Right Front Log 3 Center Log 4 Left Rear Log 5 Right Rear Log Catalog Number for the entire log set: H7547 Rest the bottom of log (5) over the "Groove" of log (3) as shown.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 9. REMOVING AND INST ALLING THE GLASS DOOR Air Shutter Adjustment Guidelines : Amount of Primary Air Flame Color Air Shutter Adjustment If.
33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Air shutter adjustment should only be performed by a qualified professional service technician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Soot will be produced if the air shutter is closed too much.
34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 11. HOOD INST ALLA TION (Refer to Figure 55) All of these appliances must have hoods installed prior to operating. In st al l ho od by s li di ng it i nt o the s lo ts o n t he l ow er ed ge o f th e c ab in et t op .
35 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. STEP 12. A TT ACHING SAFETY -IN-OPERA TION WARNINGS It is the installer’ s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
36 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Cat. No. Model Description V ent S ec tio ns (R ig id) 77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.5L12 12 Inch (305 mm) 77L72 SV4.5L24 24 Inch (610 mm) 77L73 SV4.5L36 36 Inch (914 mm) 77L74 SV4.5L48 48 Inch (1219 mm) 77L75 SV4.
37 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PE RIO R DIR EC T -V EN T G AS FI RE PLA CE S • MO DE LS SL DV T -3 0/3 5/ 40/ 45 • INS T A LLA TI ON IN ST RUC TI ONS C a t .
38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. SLDVT -30 H6165 SLDVT -35 H7293 SLDVT -40 H7294 SLDVT -45 85L66 Millivolt SIT Systems Natural Gas T o Propane Gas Conversion Kits Models Catalog No.
39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Burner Orifice Sizes Elevation 0 -4 5 0 0 f e et ( 0- 1 37 2 me t er s) Model Series Nat.Gas d ri ll s i ze ( in ch e s) Propane d ri ll s i ze ( in ch e s) SLDV T -30 #50 (0.070")* H4873 • #61 (0.
Printed in U.S.A. © 2009 Lennox Hearth Products P/N 506009-01 Rev . E 06/2011 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Een belangrijk punt na aankoop van elk apparaat Superior SLDVT-30NM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Superior SLDVT-30NM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Superior SLDVT-30NM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Superior SLDVT-30NM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Superior SLDVT-30NM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Superior SLDVT-30NM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Superior SLDVT-30NM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Superior SLDVT-30NM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.