Gebruiksaanwijzing /service van het product SLDVT-45PM van de fabrikant Superior
Ga naar pagina of 32
SLDVT Direct - Vent Gas Fireplaces INST ALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. INST ALLA TEUR : Laissez cette notice avec l'appareil. CONSOMMA TEUR : Conservez cette notice pour consultation ultérieure.
2 S af et y an d Y o u r F i r e p l a c e T o prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.
3 Afin d'éviter de vous brûler gravement ou de vous blesser , installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre. P ou r co mm a n de r un P AN N E AU D E PR O T E C TI ON L en no x ® G R A T UI T po ur v ot re fo ye r , c o ns ul t e z l es d é t ai ls d an s l a p ar t ie g a u ch e.
4 Important Safety Information 1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person . 2. Do not use this appliance if any part has been under water .
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A PP OS IT I ON D ES MI SE S E N GA RD E R EL A TI VE S À L A SÉ C UR IT É D ’U TI LI S A TI O N V ot re fo ye r a ét é l iv ré av ec d es ét iq ue tt es d e sé c ur it é qu i d oi ve nt êt re co ll ée s à cô té de s d is po si t if s de co nt rô le d u fo ye r .
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Appliance Installation, Service, and Maintenance Notices IMPORT ANT : Improper installation, adjustment, alteration, service, or main- tenance can cause injury or property damage. Refer to this manual.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. GENERAL INFORMA TION The fireplace models covered in this manual are direct-vent sealed combustion gas fireplace heaters designed for residential application. These direct-vent appliances operate with the combustion chamber completely isolated from the indoor environment.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Gas Controls/Control Compartment Access The gas con trols can be fou nd behind the control compartment access door .
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Figure 3 - SIT.
10 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS MAINTENANCE (See Maintenance Schedule, Page 26 ) R ef er to t he m a in te na nc e s c he du le fo r ma in te na nc e ta sk s, pr oc ed ure s, p er io di ci ty an d b y w ho m th ey sh ou ld be pe rfo rm ed .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Figure 6 Fron.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Figure 7 4. Placement of Glowing Embers - Separate the Embers (rockwool) into pieces about the size of a quarter (see Figure 8 ) .
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SLDVT -30 AND.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SLDVT -40 LOG.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SLDVT -45 LOG.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS BURNER ADJUST.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Air shutter adjustment should only be performed by a quali- fied professional ser vice technician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Carbon will be produced if the air shutter is closed too much.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS TP-TH TP TH O.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ACCESSORY COMPONENTS Remote Control Kit, Standard Cat. No. Model No. Description H0249 RCL Remote Control System (Standard) Remote Control Kit, Deluxe Cat.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Barrier Screen Panel Kit This easy to install optional screen panel installs over the standard glass enclosure panel and provides a barrier to prevent direct contact with the hot glass surface. These screen panels cannot be used in conjunction with the arch door kits or door frame kits.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Bag of Glowing Embers Bag of Volcanic Stone Replacement ember materials or volcanic stone are available for use with these appliances. Order kits as part of the periodic maintenance of the appliance.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS LIGHTING INSTRUCTIONS – MILLIVOL T GAS V AL VE FOR YOUR SAFETY READ BEFORE LIGHTING A.
23 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS REMARQUE : LES SCHÉMAS ET LES ILLUSTRA TIONS NE SONT PAS À L ’.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS A. When lighting the appliance, follow these instructions exactly .
25 REMARQUE : LES SCHÉMAS ET LES ILLUSTRA TIONS NE SONT PAS À L ’ÉCHELLE INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE PO UR V OT RE SÉ CU RI TÉ , LI SE Z CE S IN ST RU CT IO NS A VA NT L ’A LL UM AG E A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions.
26 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS MAINTENANCE T ASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner , Logs and Controls Qualified Service T echnician Inspect valve and ensure it is properly operating.
27 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark igniter will not light pilot after repeated triggering of igniter button.
28 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Check voltage on AC terminals of module an/or batteries.
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS LIST Gas Controls - SIT Millivolt Item No. Description Natural Gas Propane Gas Part No.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS REPLACEMENT P ARTS Dexen Gas Controls SIT Gas Controls 6 10 29 9 7 28 16 17 18 19 15 7 10 (Ref.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Notes SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Printed in U.S.A. © 2009/2011 Lennox Hearth Products P/N 506010-01 Rev .
Een belangrijk punt na aankoop van elk apparaat Superior SLDVT-45PM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Superior SLDVT-45PM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Superior SLDVT-45PM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Superior SLDVT-45PM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Superior SLDVT-45PM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Superior SLDVT-45PM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Superior SLDVT-45PM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Superior SLDVT-45PM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.