Ascensia ® B REEZE ™ and Ascensia ® A UTODISC ™ Unique 1 0 - T est Disc U SER G UIDE Diabetes Care System.
Introduction: Thank you for choosing the Ascensia ® B REEZE ™ Diabetes Care System! W e are proud to be your partner in helping you to manage your diabetes. W e understand that people who regularly check their blood glucose levels want a meter that is simple, straightforward and easy to use.
Fold this page out for easy reference when using your user guide. A look at your Ascensia B REEZE Meter… On/Off Button: Use this button to manually turn the meter On or Off. Data Port: (side of meter) Insert cable here to allow communication between meter and a personal computer .
Simply place the easy reference sticker on the Button Door as shown. See sheet of stickers provided in your meter package and select the language of your choice. On/Off Button: Use this button to manually turn the meter On or Off. Memory Button: Use this button to view your blood glucose results stored in memory and to view your 14-day average.
iv Release Button T est Strip Slot Open Latch (back of meter) Press in and pull up to open meter . Meter Handle.
T esting Materials: 10-T est A UTODISC ™ (Contains ten test strips.) Normal Control Solution M ICROLET ® Adjustable Lancing Device and Lancet Important Information: Caution: Before using any pr oduct to test your blood glucose, read all instructions car efully and practice the test.
1 T able of Contents: Everyday Use Inserting a 10-T est A UTODISC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Running a Blood Glucose T est . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Running a Control T est . .
INSERTING A 10-TEST A UTODISC ™ : W ARNING: Never open the meter with the meter handle pulled out. Open Meter 1. Hold the meter with the display screen down. Open the meter by pressing down on the back edge of the open latch and then pulling the front cover up.
Insert Disc 3. Insert a new 10-test disc—yellow arrow (bumpy side) up. The arrow may point in any direction. Close Meter 4. Close the meter and snap it shut. Keep the meter flat. J Helpful Hint: The meter must be kept flat when closing. If the meter is not kept flat, the disc may move and become damaged and you may waste test strips.
Counting Number of Strips Left Y our Ascensia ® B REEZE ™ Meter will automatically count down the number of test strips you have left. To see this count when the meter is off, press the button. Note: This count is reset to 10 every time you open the meter .
RUNNING A BLOOD GLUCOSE TEST : 1. Wash your hands well with soap and warm water . Rinse and dry thoroughly . 2. Remove the endcap from the M ICROLET ® Adjustable Lancing Device. (See M ICROLET ® Device package insert for complete instructions.) 3. Insert lancet firmly until it comes to a full stop.
4. T wist off lancet cap and replace the endcap. Push out T est Strip Caution: Y our meter is designed to push out one test strip at a time. Do not attempt to push out a new test strip with one already showing. 5. Y our Ascensia ® B REEZE ™ Meter was designed with a special, easy-to-use “Pull and Push” design.
Note: This will automatically turn your meter on if it is not al- ready on. For regular , everyday use you don’t have to worry about turning it on — just “Pull and Push. ” Note: The r elease button is UP , a test strip is pushed out and a flashing blood drop appears on the screen.
Te s t 7. Y our test strip is like a straw; it sips in a sample of blood. Move the entire front edge of the test strip to touch the edge of the blood drop. The blood is automatically pulled into the test strip and fills the test strip. Hold the test strip in place until the meter beeps, and three dashes appear on the screen, then move it away .
8. While the meter calculates your blood glucose level, you will see a sequence of dashes on the screen. After 30 seconds, your test result will appear on the screen.
9. T o r elease the used test strip, hold the meter with the test strip pointing down over a waste container . Press the r elease button. Make sure the heel of your hand is not against the meter handle. Note: If you block the meter handle with your hand, the test strip may not release properly .
For best results: •B lood is pulled IN the test strip not dropped ON. • Do not allow blood to run down into the meter . •D o not add more blood after the meter beeps.
RUNNING A CONTROL TEST : There are times when you will want to do a quality control test so you know that your system is working properly . Y ou may also want to do a control test to check the way you do your test. Simply follow these steps: Note: Look on the bottom flap of the box of test strips to find the control range.
13 Note: The r elease button is UP , a test strip is pushed out and a flashing blood drop appears on the screen. The meter is now ready to run a control test. 2. Squeeze a small drop of control solution onto a nonabsorbent surface (such as a clean piece of wax paper).
4. While the meter calculates your control test result, you will see a sequence of dashes on the screen. After 30 seconds, your control test result will appear on the screen. Compare this control test result with the range printed on the bottom flap of the test strip carton.
15 Marking a Control T est Marking a test result as a control test excludes it from the 14-day average. Y ou must mark the result immediately after the test is performed — while the result is still displayed on the screen. To do this, follow these steps: 5.
Marking a Deleted Blood T est Marking a test result as a deleted blood test excludes it from the 14-day average. Y ou must mark the result immediately after the test is performed — while the result is still displayed on the screen. To do this, follow these steps: 1.
17 RECALLING TEST RESUL TS: Y our Ascensia ® B REEZE ™ Meter can store up to 1 00 test results in its memory . This makes it easy to see your earlier blood glucose test results. T o view those results: 1. Open the Button Door . 2. Press the button.
V iewing Y our 14-Day A verage Y our Ascensia ® B REEZE ™ Meter also keeps a 14-day average of your bl ood glucose results for you ( ). T o see this aver- age, simply follow these steps. 1. Open the Button Door and press the button. The meter will show you your last result.
SETTING TIME, DA TE AND OTHER FEA TURES: J Helpful Hint: Y ou may press the button at any time during set-up to turn the meter off. Just remember to press the button first to store your changes! Setting the Time 1. Open the Button Door . 2. Press . 3.
5. Press or to select AM or PM. Press to accept and move on. Setting the Date Note: If you have just set the time, skip ahead to step 4. 1. Open the Button Door . 2. Press . 3. Press until you see the “day” icon flashing. 4. Press or to change the day .
5. Press or to change the month. Press to accept and move on. 6. Press or to change the year . Press to accept and move on. 21.
22 Setting Buzzer Level Y our Ascensia ® B REEZE ™ Meter has an easy-to-use volume control for the buzzer . Here are the three different buzzer levels: high low off Note: If you have just set the date, skip ahead to step 4. 1. Open the Button Door .
Setting Units-of-Measure Important: T est results are shown in either mmol/L or mg/dL. The mmol/L results will always include a decimal point. The mg/dL results do not include a decimal point. Example: 5 5 . . 3 3 or 9 9 5 5 Y our Ascensia ® B REEZE ™ Meter comes with the units-of- measure preset.
24 Setting Time Format (12- or 24-hour Clock) Y our Ascensia ® B REEZE ™ Meter will let you choose either a 12-hour ( ) or a 24-hour time setup ( ). Note: If you have just set the units-of-measure, skip ahead to step 4. 1. Open the Button Door . 2.
Setting Date Format Y our Ascensia ® B REEZE ™ Meter will let you set the day and month option on your meter . Y ou can choose to set it as “month/day” ( ) or as “day/month” ( ). Note: If you just set the time format, skip ahead to step 4. 1.
TRANSFERRING TEST RESUL TS TO A COMPUTER: Y ou can transfer test results from the Ascensia ® B REEZE ™ Meter to a computer , where they can be summarized in a report with graphs and tables.
CLEANING YOUR METER: Y our Ascensia ® B REEZE ™ Meter can be cleaned using a m oist (not wet) lint-free tissue with a m ild detergent or disinfect- ing solution (1 part bleach mixed with 9 parts water).
28 REPLACING THE BA TTER Y : Y our Ascensia ® B REEZE ™ Meter uses one 3-volt lithium battery (CR2025). A battery will already be installed in the meter when you buy it. When it is time to put a new battery in the meter , the meter will tell you by displaying a flashing battery on the screen.
To r eplace the battery , follow these steps: Note: A replacement battery (CR2025) can be found at most pharmacies. 1. Hold the meter with the display screen down. Open the meter by pressing on the open latch and pulling up. 2. Slide out the bat- tery holder .
4. Snap 1 new battery (CR2025) firmly in the holder with the + side up. 5. Gently slide the battery holder back into the battery compartment. Make sure battery holder is pushed all the way in. 6. Close the meter . 7. Reset the meter’ s time (see pg.
SPECIFICA TIONS: T est: Capillary blood glucose referenced to plasma/serum glucose values Calibration: Meter is automatically calibrated each time a new test strip disc is used. Sample Size: Approximately 2.5–3.5 µL T est Range: 0.6–33.3 mmol/L (10–600 mg/dL) T est Time: 30 seconds Memory Feature: Meter stores 1 00 test results.
PERFORMANCE EV ALUA TIONS: Precision 1. Laboratory Precision: To assess the repeatability (within-run precision) of Ascensia ® B REEZE ™, 100 blood glucose readings (10 readings on each of 10 instruments) were obtained with venous blood specimens at five glucose concentrations.
Normal Control Solution High Control Solution Accuracy 1. Bayer Accuracy Evaluation: To assess the accuracy of the Ascensia ® B REEZE ™ System, 102 fresh fingerstick specimens from people with diabetes were tested with the Ascensia ® B REEZE ™ (2 readings per fingerstick) and the YSI 2300 ST A T Plus Glucose Analyzer .
W eighted Deming Agreement Statistics / Pearson correlation 2. Professional / Lay User Evaluation: A patient use evaluation was conducted at two diabetes clinics. Lay users with diabetes learned to use the meter system by reviewing the meter user guide.
comparative laboratory glucose and hematocrit determinations. The glucose concentrations of the 196 samples ranged from 2.9 to 28.2 mmol/L with an average of 8.9 mmol/L. The range of hematocrits was 32 to 55%, with an average of 45%. 35 0.0 5.0 10.0 15.
Comparison of Meter to Laboratory Results † † Weighted Deming regression, weighted linear correlation coef ficient Opr . = Operator; Lay = Lay User; HCP = Healthcare Professional 36 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 0.0 5.0 10.0 15.0 20.0 25.
MUL TIPLE SITE TESTING EV ALUA TION: Forty-one persons with diabetes, in steady state for glucose, performed self-capillary blood glucose assays using the Ascensia ® B REEZE ™ System and one test strip lot (Lot A). A fingerstick was performed with the M ICROLET ® Adjustable Lancing Device.
38 Comparison of Multiple Site to Fingertip Results † † Weighted Deming regression, weighted linear correlation coef ficeint ‡One outlier excluded from statistics, but included in data plot Opr . = Operator; Lay = Lay User; 95% Confidence Intervals Site Opr .
PROBLEM SOL VING: Y ou can solve many of the problems you might have by working through this section. 1. Do you have a 10-test disc in the meter? Y es____ No_____ No? (see pg. 2) 2. Does it contain new test strips? Y es____ No_____ No? (see pg. 2) 3. Is the 10-test disc within its expiration date? Y es_____ No______ No? (see pg.
The 10-test disc is out of test strips. Insert a new 10-test disc. 40 Y ou have not pushed the meter handle all the way in. Push the meter handle in until it clicks. Y ou must push the handle all the way in and see the flashing blood drop before you touch the strip to the blood drop.
41 What Y ou See What It Means What Y ou Do T emperature is either too hot or too cold. Allow the meter to reach room temperature. T est strip removed during the test, or release button pressed during the test. T ake care to not press release button or remove test strip during test.
42 What Y ou See What It Means What Y ou Do Y our Blood Glucose Level is very high or meter error . Tu rn meter off, then on using . Retest. If error appears again, call your physician or healthcare professional (HCP). Y our blood glucose may be above 55.
43 What Y ou See What It Means What Y ou Do Meter Malfunction T urn meter off, then on using . Retest. If error remains, contact the Bayer Diabetes Helpline (see pg.
44 This may affect the way you see your results. If there is a difference in your meter’ s display and the one shown on page v , contact the Bayer Diabetes Helpline (see pg. 45). Some display segments do not appear to be working when the meter handle is all the way out.
CUSTOMER SERVICE: If a problem arises, work through the Solving Problems section (see pg. 39). Y ou may easily find your solution there. If you are still having trouble, please call our Bayer Diabetes Helpline. W e have friendly , knowledgeable people who are there to help 12 hours a day , 7 days a week (9 – 9 EST).
46 REPLACEMENT ITEMS: If you call or write for supplies, please include the number with the name of the replacement part or product. Replacement Parts Part Number* Item 40030035 1 lithium battery (CR2025) (available at most stores) Duracell Inc.
5-YEAR LIMITED W ARRANTY : Manufacturer’ s W arranty: Bayer Inc. Healthcare Division (“Bayer”) warrants to the original purchaser that this instrument will be free from defects in materials and workmanship for 5 years from the date of original purchase (except as noted below).
4. Bayer has no knowledge of the performance of the Ascensia ® B REEZE ™ Meter when used with any T est Strip Discs other than Ascensia ® A UTODISC ™ T est Strip Discs, and therefore makes no wa.
Bayer and Bayer Cross are registered trademarks of Bayer AG, used under license by Bayer Inc. 99A61189 Rev . 4/ 04 © 2003 Bayer HealthCare LLC Made and Printed in U . S . A. Manufactured by: Bayer HealthCare LLC Subsidiary of Bayer Corporation Mishawaka, IN 46544 U .
Een belangrijk punt na aankoop van elk apparaat Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bayer HealthCare Ascensia Breeze Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.