Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: y Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. y Contact a professional, quali fi ed service agency for installation, start-up or service work.
2 Contents Burner Application Scope and Intended Use ........... 2 Prepare Before Installing ............................................ 3 Speci fi cations ..................................................................... 3 Notice Special Requirements.
3 12 Vdc ADC Burner Manual Section: Prepare Before Installing Owner ’ s Responsibility Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
4 Figure 1. T ypical Burner Nameplate T able 1. Low Firing Rate Baf fl e Head T ype Low Firing Rate Baf fl e (if speci fi ed) F0 up to 0.65 gph F3 up to 0.85 gph F4 or F6 up to 0.90 gph T able 2. Air Tube Combination (A TC) Codes Firing Rate GPH Head Static Plate Size A TC Codes for Usable Air T ube Lengths: (‘A ’ in inches see Fig.
5 12 Vdc ADC Burner Manual 10 11 6 8 1 2 7 4 9 3 5 4 90 ° Contacts to be parallel with horizontal center line within 2°. Electrode gap to be centered with nozzle center .
6 Figure 4. ‘Z’ Dimensions Using Gauge SK9787 Section: Nozzle Assembly Maintenance B. Check/Adjust Electrodes Check the electrode tip settings. Adjust if necessary to comply with the dimensions shown in Figure 2 . T o adjust, loosen the electrode clamp screw and slide/rotate electrodes as necessary .
7 12 Vdc ADC Burner Manual For oil supply system speci fi cations for tanks not mounted on machines, carefully follow the pump manufacturer ’s literature and the latest edition of the National Fire Protection Association (NFP A) 31 standard. Pumps with automatic bypass do not require a bypass plug.
8 Section: Burner Wiring Figure 6A. T ypical Wiring For Constant Duty Ignition - With No Primary Control Figure 6B. T ypical Wiring For Interrupted Ignition - With No Primary Control 30A FUSE IGNITER .
9 12 Vdc ADC Burner Manual Figure 6C. T ypical Wiring with 7556 Primary Safety Control Section: Drive Component Maintenance Driv e Component Maintenance A.
10 Section: Drive Component Maintenance B. Pump Maintenance General Pump Information Important information - Long or oversized inlet lines may require the pump to operate dry during initial bleeding period. In such cases, the priming may be assisted by injecting fuel oil in the pump gear set.
11 12 Vdc ADC Burner Manual Section: Start Up Burner & Set Combustion Explosion and Fire Hazard Failure to follow these instructions could lead to equipment malfunction and result in heavy smoke emission, soot-up, hot gas puff-back, fi re and asphyxiation hazards.
12 Section: Maintain & Service Burner Professional Service Required Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
13 12 Vdc ADC Burner Manual T roubleshooting Oil burners that are designed for use on road maintenance equipment are built to take temperature extremes, vibration, and rough handling.
14 Section: T roubleshooting T able 4. Troubleshooting Chart Symptom Possible Cause Oil Not Igniting If the burner is not igniting, the burner motor , drive coupling, and oil pump are operating and oil is fl owing to the nozzle through the solenoid valve, check the following possibilities.
15 12 Vdc ADC Burner Manual 1 2 3 4 5 6 7 8 9 12 10 11 13 14 15 16 18 19 17 21 20 22 23 R eplacement P ar ts Illustration # Description Part# 1 DC Motor n/a 2 Blower Wheel 2999U 3 Coupling 2140501 4 A.
The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship.
Een belangrijk punt na aankoop van elk apparaat Beckett ADC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Beckett ADC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Beckett ADC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Beckett ADC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Beckett ADC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Beckett ADC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Beckett ADC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Beckett ADC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.