E6581373 TOSVERT VF-FS1 series L ON W ORKS ® option unit Communication Func tion Manual NOTICE 1. Make sure that this ins truction m anual is delivered to the end user of L ON W ORKS option unit. 2. Read this manual befor e installing or operating the L ON W ORKS option unit.
E6581373 - 1 - Introduction Thank you for purchasing the “ L ON W ORKS option unit” f or TO SVERT VF- FS1 series inverter. Before us ing L ON W ORKS option unit, car efully read this function m anual in order to com pletely and cor rectly utilize its excellent perf orm ance.
E6581373 - 2 - Table of Contents 1. Scope ........................................................................................................................ ..........................4 1.1. Overview ..............................................
E6581373 - 3 - 6.5.8. nviEme rgOverride (Em ergency stop) ............................................................................. 25 6.5.9. nviParamCm d (Param eter access ) .......................................................................
E6581373 - 4 - 1. Scope 1.1. Overv iew L ON W ORKS technology is a network contr ol system c oncept developed by Echelon Corporation, L ON W ORKS network provides Local O perating N etwork that is super ior in the distributed c ontrol. it is featured by peer to peer com m unication between the L ON W ORKS nodes.
E6581373 - 5 - 2. Names and functions of main par t s 2.1. Outline view The drawings below show nam es of m ain parts. Refer to each instr uction m anual for ins talling and wiring. 2.1.1. LIU006Z 2.1.2. LIU007Z (for VF-FS1) *1: Refer to f ollowing section.
E6581373 - 6 - 2.2. Diagnosti cs 2.2.1. Service LED Service LED indicates the node condition. 1 2 3 4 5 6 1 345 2 LED OFF LED ON Power ON Time (second) Continues to be OFF Continues to be ON Momentari.
E6581373 - 7 - 2.2.2. Status LED It displays node status with green color. LIU007Z does not have this LED. 1 2 3 4 5 6 12 LED OFF LED ON Power ON Time (second) Continues to be OFF Continues to be ON R.
E6581373 - 8 - 2.3. RS485 comm unication port RS485 port is usef ul for RS485 serial com m unication option (USB001Z ) or Rem ote Keypad (RKP002Z). Refer to the inver ter instruc tion m anual for details .
E6581373 - 9 - 3. Configurations 3.1. Neur on ID L ON W ORKS device has the individual Neuron ID. The ID is indicated on the option unit as the barcode (EAN128).
E6581373 - 10 - 3.6. Command & Setpoint selection (Local/Remote) Indication to display Local/Remote m ode is on the inverter unit (Ref er to the inverter instruction m anual for details ). L ON W ORKS option com mand and s etpoint are activated on Rem ote m ode *1 .
E6581373 - 11 - 3.7. Reference parameter of the inverter Referenc e param eter of the inver ter is listed below. Title Nam e Descr iption acc Acceleration tim e dec Deceleration tim e fh Maxim um f re.
E6581373 - 12 - 4. Functional profile 4.1. Functional profil e supported by thi s option Thi s L ON W ORKS option unit supports L ON M ARK Variable Speed Motor Drive func tional profile (SFPTvar iableSpeedMotorDrive, 6010_11). It has 2 objec ts (func tional block s) shown in the f igure below.
E6581373 - 13 - 5. Node Object functional block The Node Object func tional block includes 2 m andatory network var iables “nviReques t (Objec t request)” and “nvoStatus (objec t status)” .
E6581373 - 14 - 5.2.1. nciLocation (Location Label) Configuration pr operty , Node Object 0000_20 ( Optional) SNVT type: SNVT_str_as c (36) SCPT ref erence: SCPT _location ( 17) It can be used to provide physical location inf orm ation. - Valid Range: Any NULL ( “ 0” ) term inated ASCII str ing of 31 bytes total length.
E6581373 - 15 - 5.2.3. nvoStatus (Obj ect Status) Output network var iable, Node Object 0000_20 (Mandator y ) SNVT type: SNVT_obj_status (93) This is the variable to inform the object s tatus. L ON W ORKS option unit supports s ome status s hown in the table below.
E6581373 - 16 - 6. ACMotorDriv e functional block ACMotorDrive f unctional block includes the “V ariable Speed Motor Drive (6010_11)”. It can perf orm Run/stop contr ol of the inverter , intensive surveillanc e c ontrol of an oper ation state, m onitor the inver ter status through network variables.
E6581373 - 17 - 6.2. Netw ork variable list (VSD_6010_11) L ON W ORKS option unit supports all m andatory netw or k variables included in L ON M ARK func tional profile “Variable Speed Motor Drive” . The network variables are s hown in the table below.
E6581373 - 18 - 6.3. Netw ork variable list (the other) The other network variables ar e shown in the table below. . LIU 007Z LIU 006Z Variables SNVT_ty pe. unit Def ault value v nviResetFault SNVT_switch 0.5%,1 {0.0%, 0} v nviInvSetFreq SNVT _freq_hz 0.
E6581373 - 19 - 6.4. Confi guration properti es 6.4.1. nciMaxSpeed ( Maximum Speed ) Configuration pr operty (nc50), Var iable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_lev_percent ( 81) SCPT ref erence: SCPT m axSetpoint (50) It is used to define the m axim um speed of the inverter output.
E6581373 - 20 - 6.4.3. nciRcvHrtB t (Receiv e Heartbeat Time) Configuration pr operty , Vari able Speed Drive 6010_11 (Optional) SNVT type: SNVT_tim e_sec ( 107) SCPT ref erence: SCPT m axRcvT im e (4.
E6581373 - 21 - 6.4.6. nciNmlSpeed (Nominal M otor Speed in min -1 ) Configuration pr operty , Variable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_rpm (102) SCPT ref erence: SCPT nom RPM (158) It is used to provide the nom inal s peed of the inverter output in m in -1 .
E6581373 - 22 - 6.4.9. nciRampDow nTm (Ramp Dow n Time) Configuration pr operty , Variable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_tim e_sec ( 107) SCPT ref erence: SCPT ram pDownTm (161) It determ ines the ram p down time of the motor . - Valid range: 0.
E6581373 - 23 - 6.5. Input netw ork variable s 6.5.1. nviD rvSpeedSt pt (Drive Speed Setpoint) Input network variable, Var iable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_switch (95) It provides star t/stop control and a low res olution speed setpoint as a per cent of nom inal speed.
E6581373 - 24 - 6.5.4. nviInv SetFreq (Frequency Setpoint) Input network variable SNVT type: SNVT_fr eq_hz (76) It provides speed setpoint in Hz. T he rotation di rection is provided by “ nviDrvSpeedScale” (Negative value means in revers e). - Valid range: 0.
E6581373 - 25 - - Valid range LIU007Z LIU006Z Bit Term inal Par ameter T erm inal Param eter 0 --- --- 1 --- --- 2 --- --- 3 --- --- 4 --- --- 5 --- --- 6-15 --- --- If multiple digital output c ontrol s ignals are used at the sam e tim e, the output value is the OR of all digital output controls.
E6581373 - 26 - 6.5.9. nviParamCmd (Parameter access) Input network variable SNVT type: SNVT_preset ( 94) It is used to acces s the inverter par ameter s.
E6581373 - 27 - 6.6. Output netw ork variables 6.6.1. Output netw ork variable update Norm ally , output network variables are updated when the inverter st atus was changed. Autom atic transm ission func tion is also prepared by “nciSndHrtBt (Send Heartbeat Tim e)”, “ nciMinOutT m (Minim um Send Tim e)” c onfiguration pr operties.
E6581373 - 28 - 6.6.6. nvoDrvFeedback ( Velocity Feedback) Output network var iable SNVT type: SNVT_switch (95) It provides stopped / r unning status and low resolution output s peed of the m otor. - Specif ication nvoDrvFeedback value state Operation N/A 0 Stop 0.
E6581373 - 29 - 6.6.9. nvoA larmWord (Alarm Status) Output network var iable SNVT type: SNVT_state (83) It provides the inverter fault status . If the inverter faulted, “Fault” bit and the contents bit are set to ON. Bit De scription 0 Fault 1 Supply fault 2 Inverter fault 3 Motor f ault (overvoltage, phase los s, overheating .
E6581373 - 30 - 6.6.13. nv oDrvEnergy (Cumulative Input Energy ) Output network var iable, SNVT type: SNVT_elec_k wh_l (146) It provides the cum ulative input ener gy c alculated by the inverter. - Valid range: 0.0k W h to 42949672.9kW h ( If an overf low occurred, the value retur ns to 0.
E6581373 - 31 - The relations hip between the network variables and input ter minals is shown in below. Variables LIU007Z LIU006Z nvoDigitalIn1 F term inal nvoDigitalIn2 R term inal nvoDi gitalIn3 ------- nvoDi gitalIn4 ------- nvoDi gitalIn5 ------- nvoDi gitalIn6 ------- nvoDi gitalIn7 ------- nvoDi gitalIn8 ------- 6.
E6581373 - 32 - 6.6.18. nvoParamResp (P arameter Access Response) Output network var iable SNVT type: SNVT_preset ( 94) It provides to the respons e of the inverter par ameter s acce ssing ( nviParam Cm d). Refer to section 7.5 “Param eter acc ess m ethod” for the exam ple usage.
E6581373 - 33 - 7. Example usage 7.1. Procedure Lower exam ple shows the procedur e to send the 100% speed drive c omm and to the inverter . 1. Comm iss ion Make a network tool to identify this option by using s ervice pin f unction (ref er to network tool manual in detail) .
E6581373 - 34 - 7.4. Communicati on health management This option unit has com m unication health m anagem ent function. 1. Comm unic ation time out f unction (nciRc vHrtBt) This value manages the com m unication time out func tion.
E6581373 - 35 - 7.5. Parameter access method Param eter acc ess is allowed by us ing nviParam Cm d and nvoParam Resp network var iables. T he struc ture form at is shown in below table.
E6581373 - 36 - - Exam ple 3: Illegal acc ess Illegal data is written to the inverter param eter f171 , (Base f requency voltage, address 0171) . The upper lim it value is 330.0V ( 200V class) . In case of writing 360.0V, the unit of this param eter is 0.
E6581373 - 37E - 8. Specifications Item Specific ation Notes Number of dom ains 2 Number of addres s entries 37 Number of alias tables 8 Comm unic ation transceiver Free topology transceiver TP/FT -10 channel type. ANSI/EIA/CEA 709.3 Baudrate 78k bps Protocol LonT alk ANSI/EIA 709.
Een belangrijk punt na aankoop van elk apparaat Toshiba TOSVERT VF-FS1 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Toshiba TOSVERT VF-FS1 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Toshiba TOSVERT VF-FS1 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Toshiba TOSVERT VF-FS1 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Toshiba TOSVERT VF-FS1 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Toshiba TOSVERT VF-FS1 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Toshiba TOSVERT VF-FS1 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Toshiba TOSVERT VF-FS1 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.