Gebruiksaanwijzing /service van het product TAM7A0C36H31SB van de fabrikant Trane
Ga naar pagina of 28
V ariab le Speed Modular Multi-position Air Handler s 2-5 T ons T AM7A0A24H21SB T AM7A0B30H21SB T AM7A0C36H31SB T AM7A0C42H31SB PUB. NO . 22-1847-03 T AM7A0C48H41SB T AM7A0C60H51SB T AM7B0C60H51SA.
2 Pub . No . 22-1847-03 Featur es and Benefits © 2012 T rane • Unique cabinet design – 2% or less air leakage – Precision applied - durab le door seals – Specially designed air seal around refrigerant, condensate and conduit connections – Double w all f oamed cabinet system – R-4.
Pub . No . 22-1847-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 T AM7A0A24H21SB 6 T AM7A0B30H21SB 6 T AM7A0C36H31SB 6 T AM7.
4 Pub . No . 22-1847-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEV AC05BK1AA Electric Heater , 5kW , Breaker , RS-485 Control, 1 Ph A to C BA YEV AC05LG1AA Electric Heate.
Pub . No . 22-1847-03 5 5 Conduit Connections Locations r Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s 7 Alert Code Viewport e Compact 20.
6 Pub . No . 22-1847-03 General Data PRODUCT SPECIFICA TIONS MODEL T AM7A0A24H21SB RA TED V OL TS/PH/HZ. 200-230/1/60 RA TINGS 1 See O .D . Specications INDOOR COIL — T ype Plate Fin Rows — F .P .I. 3 - 14 F ace Area (sq. ft.) 3.67 T ube Size (in.
Pub . No . 22-1847-03 7 T AM7A0A24 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
8 Pub . No . 22-1847-03 T AM7A0B30 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
Pub . No . 22-1847-03 9 T AM7A0C36 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
10 Pub . No . 22-1847-03 Minimum Heating Airo w Settings T AM7A0C42 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
Pub . No . 22-1847-03 11 Minimum Heating Airo w Settings T AM7A0C48 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
12 Pub . No . 22-1847-03 Minimum Heating Airo w Settings T AM7A0C60H51SB, T AM7B0C60H51SA AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
Pub . No . 22-1847-03 13 Electrical Data Notes: 1. See Air Handler nameplate for appro ved combinations of Air Handlers and Heaters 2. Heater model numbers may ha v e additional sufx digits. kW BTUH kW BTUH No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15 BAYEVAC05++1 1 4.
14 Pub . No . 22-1847-03 Electrical Data kW BTUH kW BTUH No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15 BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25 BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40 BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.
Pub . No . 22-1847-03 15 Electrical Data kW BTUH kW BTUH No Heater 0 - - 4.2** 5 15 - - 4.2** 5 15 BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.
16 Pub . No . 22-1847-03 Electrical Data kW BTUH kW BTUH No Heater 0 - - 5.5** 7 15 - - 5.5** 7 15 BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.
Pub . No . 22-1847-03 17 AIR HANDLER ELECTRIC HEA TER PRESSURE DROP Air handler electric heater pressure drop is negligib le f or the heaters and is inc luded in the airow data f or the Series 7 air handler s.
18 Pub . No . 22-1847-03 T AM7 AIR HANDLER AND HEA TER MA TRIX - ALLO WBLE COMBINA TIONS Electrical Data AIR HANDLER MODEL NUMBER AC05BK1AA 4.80 Kw BK AC05LG1AA 4.80 Kw LG AC08BK1AA 7.68 Kw BK AC08LG1AA 7.68 Kw LG AC10BK1AA 9.60 Kw BK AC10LG1AA 9.60 Kw LG BC15BK1AA 14.
Pub . No . 22-1847-03 19 Electrical Data WIRING DIA GRAM FOR T AM7 AIR HANDLERS.
20 Pub . No . 22-1847-03 Comfort Control Air Handler Air Conditioner Neatly bundle all low voltage wires behind the service valve cover as shown. Field wiring Y ellow Blue Red Y ellow Green White Blue.
Pub . No . 22-1847-03 21 Comfort Control Air Handler Heat Pump Neatly bundle all low voltage wires behind the service valve cover as shown. Field wiring Y ellow Blue Black (X2) Red Orange Red Y ellow .
22 Pub . No . 22-1847-03 T wo Stage Cooling Field Wiring Comfort Control Air Handler Air Conditioner Neatly bundle all low voltage wires behind the service valve cover as shown.
Pub . No . 22-1847-03 23 Comfort Control Air Handler Heat Pump Neatly bundle all low voltage wires behind the service valve cover as shown. Y ellow/Red Field wiring Y ellow Blue Black (X2) Red Orange .
24 Pub . No . 22-1847-03 T AM7 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Downflo w Condensate Drains Refrigerant Conne.
Pub . No . 22-1847-03 25 Dimensions T AM7 AIR HANDLER DIMENSIONAL D A T A T AM7 AIR HANDLERS ARE ALL TWO PIECE CABINETS. Model No . H W D T AM7A0A24H21SB 49.9 17.5 21.75 T AM7A0B30H21SB 55.7 21.3 21.75 T AM7A0C36H31SB 56.9 23.5 21.75 T AM7A0C42H31SB 56.
26 Pub . No . 22-1847-03 T AM7 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE LIQ LINE BRAZE T AM7A0A24H21SB 49.9 17.5 14.5 39.6 14.5 7.3 24.4 EEV 3/4 3/8 T AM7A0B30H21SB 55.7 21.3 18.4 45.5 18.4 9.2 24.8 EEV 3/4 3/8 T AM7A0C36H31SB 56.
Pub . No . 22-1847-03 27.
T rane 6200 T roup Highway T yler , TX 75707 www .trane.com 03/12 The manuf acturer has a policy of continuous product and product data improv ement and it reserves the right to change design and specifications without notice.
Een belangrijk punt na aankoop van elk apparaat Trane TAM7A0C36H31SB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Trane TAM7A0C36H31SB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Trane TAM7A0C36H31SB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Trane TAM7A0C36H31SB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Trane TAM7A0C36H31SB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Trane TAM7A0C36H31SB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Trane TAM7A0C36H31SB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Trane TAM7A0C36H31SB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.