Gebruiksaanwijzing /service van het product TUH2C100A9V4VA van de fabrikant Trane
Ga naar pagina of 30
XV 95 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A PUB. NO . 22-1814-08 Upflo w/ Horizontal Left, Do wnflo w/ Horizontal Right V ariab le Speed T w.
2 Pub . No . 22-1814-08 General Features © 2012 T rane All Rights Reser ved NA TURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Associa - tio n for both natur al and L.
3 Pub . No . 22-1814-08 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A .
4 Pub . No . 22-1814-08 XV 95 ST AND ARD EQUIPMENT Features and Benefits • Lite P or t ™ e xtended system diag - nostics • Stored f ault code history in micro pro - cessor nonv ocatile memor y .
5 Pub . No . 22-1814-08 Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... T A YST A T241 [ ] Thermostat, Media Programmable 2-Stage Heating .
6 Pub . No . 22-1814-08 General Data 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
7 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No .
8 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No .
9 Pub . No . 22-1814-08 *UH2B060A9V3V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.
10 Pub . No . 22-1814-08 *UH2B080A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.
11 Pub . No . 22-1814-08 *UH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.
12 Pub . No . 22-1814-08 *UH2C100A9V4V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.
13 Pub . No . 22-1814-08 *UH2C100A9V5V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 62,855 96,700 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.
14 Pub . No . 22-1814-08 *UH2D120A9V5V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.
15 Pub . No . 22-1814-08 *DH2B060A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 37,440 57,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.
16 Pub . No . 22-1814-08 *DH2B080A9V3V - FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.
17 Pub . No . 22-1814-08 *DH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 49,400 76,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.
18 Pub . No . 22-1814-08 *DH2C100A9V4V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 62,400 96,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.
19 Pub . No . 22-1814-08 *DH2D120A9V5V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 74,880 115,200 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 8 SW 7 0.
20 Pub . No . 22-1814-08 Maxim um V ent Length T able VENT LENGTH T ABLE AL TITUDE MAXIMUM T OT AL EQUIV ALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NO TES) 0-7,000 F eet 2 INCH PIPE 2.
21 Pub . No . 22-1814-08 Electrical Data *UH2 WIRING DIA GRAM F rom drawing D344303.
22 Pub . No . 22-1814-08 Electrical Data *UH2 SCHEMA TIC DIA GRAM F rom drawing D344303.
23 Pub . No . 22-1814-08 *DH2 WIRING DIA GRAM Electrical Data F rom drawing D344304.
24 Pub . No . 22-1814-08 *DH2 SCHEMA TIC DIA GRAM Electrical Data F rom drawing D344304.
25 Pub . No . 22-1814-08 FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING ONL Y Field Wiring.
26 Pub . No . 22-1814-08 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING/ SINGLE ST A GE COO.
27 Pub . No . 22-1814-08 Dimensions *UH2 UPFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES).
28 Pub . No . 22-1814-08 *DH2 DO WNFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) Dimensions.
29 Pub . No . 22-1814-08 Notes.
T rane has a policy of continuous product and product data improv ement and i t reser ves the right to change design and specifications without notice.
Een belangrijk punt na aankoop van elk apparaat Trane TUH2C100A9V4VA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Trane TUH2C100A9V4VA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Trane TUH2C100A9V4VA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Trane TUH2C100A9V4VA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Trane TUH2C100A9V4VA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Trane TUH2C100A9V4VA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Trane TUH2C100A9V4VA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Trane TUH2C100A9V4VA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.