Upflo w/Horizontal T w o-sta ge Condensing Gas-Fired Furnace XV 90 TUY060,080,100,120R9V V ariable Speed Blo wer V ariable Speed Inducer PUB. NO . 22-1682-05-0802 (EN) TDD-D-1.
2 Pub. No. 22-1682-05-0802 (EN) General Features © 2002 American Standard Inc. All Rights Reserved NA TURAL GAS MODELS Central heating furnace designs are cer tified b y the Inter national Approv al Services (IAS) for both natural and L.
3 Pub. No. 22-1682-05-0802 (EN) Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V P erformance Data Elec.
4 Pub. No. 22-1682-05-0802 (EN) XV 90 ST AND ARD EQUIPMENT Features and Benefits • Variable speed indoor blower • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blo.
5 Pub. No. 22-1682-05-0802 (EN) Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... T A YS T A T241 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .
6 Pub. No. 22-1682-05-0802 (EN) TUY-R9V PRODUCT SPECIFICA TIONS 1 MODEL RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE (ICS) T emp. Rise (Min.-Max.) °F . BLO WER DRIVE Dia.-Width (In.
7 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data *UY060 R9V3V FUR NA CE COOLING AIRFL O W (CFM) AND PO WE R (W A TT S) VS. EX TERNAL ST A TIC PRESSUR E WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFL OW SETTI NG DIP SWITC H SETTING EXTERN AL ST A TIC PR ESSURE SW 1 SW 2 SW 3 SW 4 0.
8 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY080 R9V3V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.
9 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY100 R9V4V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.
10 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY120 R9V5V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.
11 Pub. No. 22-1682-05-0802 (EN) SCHEMA TIC DIAGRAMS FOR GAS FURNA CES TUY060,080,100,120R9V -V LEGEND Electrical Data From Dwg. 21D341111 P03.
12 Pub. No. 22-1682-05-0802 (EN) TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING F rom Dwg. 21B341127 Rev . 0 F rom Dwg. 21B341126 Rev . 0 FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING THERMOST A T TO 115 V 1 PH.
13 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg.
14 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING TWO ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg.
15 Pub. No. 22-1682-05-0802 (EN) Dimensions TUY-R9V -V OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES).
Since T rane has a policy of continuous product improv ement, it reserves the right to change design and specifications without notice. T rane A business of American Standard Companies www .
Een belangrijk punt na aankoop van elk apparaat Trane XV 90 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Trane XV 90 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Trane XV 90 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Trane XV 90 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Trane XV 90 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Trane XV 90 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Trane XV 90 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Trane XV 90 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.