MOPS/586 Technical Manual Rev. 1.4 JUMP tec Industrielle Computertechnik AG Brunnwiesenstraße 16 94469 Deggendorf/ Germany Tri-M Systems Inc., 6-1301 Ketch Court, Coquitlam, B.C., V3K 6X7, Canada Phone: (604) 527-1100, (800) 665-5600 Fax: (604) 527-1110 Email: info@Tri-M.
MOPS/586 Table of Contents Table of Contents TABLE OF CONTENTS .......................................................................................................................................... 2 USER INFORMATION ..............................
MOPS/586 Table of Contents F LOPPY C ONNECTOR ............................................................................................................................................... 30 IDE C ONNECTOR FOR 2,5" H ARD D ISK .................
MOPS/586 User Information User Information Copyright 1997 JUMP tec ® Industrielle Computertechnik AG. In this document JUMP tec ® Industrielle Computertechnik AG will also be referred to by the short form " JUMP tec ® ". The information in this document has been carefully checked and is believed to be accurate and reliable.
MOPS/586 User Information Warranty Each board is tested carefully and thoroughly before being shipped. If, however, problems should occur during the operation, please check your user specific settings of all boards included in your system. This is often the source of the fault.
MOPS/586 Features Features • Processor AMD Am5x86 ® with 133 MHz internal Clock and 16 kByte write-back-Cache • Chipset ALI 1489/1487 PCI Chipset • Power Supply 5V only supply • Memory 4 MB o.
MOPS/586 I/O Map I/O Map The I/O-port addresses of the processor module MOPS/586 are functionally identical with a standard PC/AT. I/O Addresses MOPS/586 - onboard Function 0000 - 001F X DMA-Controlle.
MOPS/586 Memory Map for BIOS, SSD and JRC Support Memor y Map for BIOS, SSD and JRC Support The BIOS includes two special extensions to support the onboard silicon state disk and Jumptec Remote Control. If the SSD is enabled in setup or the JRC client finds a host the code of the bios extension will be copied into shadow ram.
MOPS/586 Onboard SSD (DOS-compatible) Expanded Memory Map The user can convert (up to 20Mbytes) Extended Memory into Expanded Memory (EMS). The selected Expanded Memory is devided into 16KByte pages, of which four can be mapped into the EMS-frame. The EMS- frame is located within the first 1MByte address space and has a length of 64KByte.
MOPS/586 Block Diagram Block Diagram CPU DRAM ALI Chipset Cache RTC EIDE BIOS IO-Con- troller Ethernet- Con- troller COM1 COM2 LPT1 10baseT IS A-Con. Tri-M Systems Inc., 6-1301 Ketch Court, Coquitlam, B.C., V3K 6X7, Canada Phone: (604) 527-1100, (800) 665-5600 Fax: (604) 527-1110 Email: info@Tri-M.
MOPS/586 Connector Arrangement Connector Arrangement Tri-M Systems Inc., 6-1301 Ketch Court, Coquitlam, B.C., V3K 6X7, Canada Phone: (604) 527-1100, (800) 665-5600 Fax: (604) 527-1110 Email: info@Tri-M.
MOPS/586 BIOS-Description BIOS-Description The Standard AMI-BIOS is located in the Flash EPROM onboard. This device has 8 bit wide access. 16 bit access is enabled by the shadow RAM feature (Standard). RTC-CMOS setup menu During boot sequence the CMOS setup can be entered by pressing the <DEL>-key while the memory test is in progress.
MOPS/586 BIOS-Description • WPcom (starting write precompensation cylinder) • Sec (number of sectors) Parameter Description Type The number for a drive with certain identification parameters. Cylinders The number of cylinders in the disk drive. Heads The number of heads.
MOPS/586 BIOS-Description Advanced CMOS Setup Quick Boot Set this option to Enabled to instruct AMIBIOS to boot quickly when the computer is powered on. This option replaces the former Above 1 MB Memory Test Advanced Setup option. The settings are: Setting Description Disabled AMIBIOS tests all system memory.
MOPS/586 BIOS-Description Wait For 'F1' if Error If this option is Enabled the system will wait on power up for the user to press the <F1> key on any occurring error.
MOPS/586 BIOS-Description Power Management Setup Power Management/APM If this option is Disabled, none of the below listed options are available, the system doesn't provide you with power save features. The Optimal and Fail Safe default settings are Disabled.
MOPS/586 BIOS-Description Peripheral Setup Onboard IDE This option enables the onboard IDE controller. The settings are Disabled and Enabled. The Optimal and Fail Safe default settings are Enabled. Onboard FDC This option enables the floppy drive controller on the motherboard.
MOPS/586 BIOS-Description This option enables the silicon state disk as either drive 80h, 81h, 82h, or 83h (C, D, E or F). The settings are Disabled, 80h, 81h,82h, 83h. The Optimal and Fail Safe default settings are Disabled . SSD Write Protect This option allows to write protect the silicon state disk.
MOPS/586 BIOS-Description AMIBIOS Configuration Screen AMIBIOS System Configuration (C) 1985-1996, American Megatrends Inc., Main Processor : Am5x86 (X5) Base Memory Size : 640KB Math Processor : Built-In Ext. Memory Size : 3072KB Floppy Drive A: : 1.
MOPS/586 Hardware Description Hardware Description ALI-Chipset Features The MOPS/586 Board operates with the chipset ALI 1489/87, which provides following features: • 32 bit PCI Interface • integrated DRAM controller • integrated PMU controller • integrated PCI to ISA bridge (fully compliant to PCI 2.
MOPS/586 Hardware Description Interrupts IRQ0 System Timer IRQ1 Keyboard IRQ2 Cascade IRQ3 COM 2 note (1) IRQ4 COM 1 note (1) IRQ5 Ethernet (default) note (2) IRQ6 Floppy IRQ7 LPT 1 IRQ8 Clock/Calenda.
MOPS/586 Hardware Description The JIDA Standard JIDA is the abbreviation for JUMP tec ® Intelligent Device Architecture. Every board with onboard BIOS extension shall support the following function calls, which supply information about the board.
MOPS/586 Hardware Description Get Manufacturing Date Int 15h Input: AX = EA02h DX = 4648h CL = Board number Output: CL=0: Board present CL ≠ 0: Board not present DX=6B6Fh: Function successful DX ≠ 6B6Fh: Fn.not implemented BX = Manufacturing date Description If CL=0 and DX=6B6Fh, then BX=Manufacturing date.
MOPS/586 Hardware Description Read Running Time Meter Int 15h Input: AX = EA07h DX = 4648h CL = Board number Output: CL=0: Board present CL ≠ 0: Board not present DX=6B6Fh: Function successful DX ≠ 6B6Fh: Fn.
MOPS/586 Hardware Description Watchdog Extension With the aid of a special Interrupt 15h function, the watchdog on a JUMPtec board can be controlled very easily. The respective functions have the following calling conventions: Watchdog init Int 15h 00h Input: AH = E0h AL = 00h BX = timeout in 0.
MOPS/586 Network Operation Returns no Example mov ax,0E000h ; Watchdog set mov bx,5 ; 5*0,2s = 1s Timeout mov cx, 5 ; 5*0,2s = 1s Delay mov dx,0 ; after Timeout and Delay generate RESET int 15h Network Operation Overview The Crystal LAN ™ CS8900 ISA Ethernet Adapter from Crystal Semiconductor follows IEEE 802.
MOPS/586 Specifications Specifications Mechanical Specifications PC/104 Bus connector: 2 pieces of 2*32 pin male and 2*20 pin male connector Module-dimensions: length * width 95 mm * 90 mm (3,7" .
MOPS/586 Peripheral Interface Peripheral Interface Keyboard, Reset, Battery, Speaker Pin Signal name Function 5-pin diode keyboard adapter 6-pin minidin keyboard adapter (PS2) 1 SPKR speaker output 2 .
MOPS/586 Peripheral Interface 1 (Speaker) 2 (GND) 3,10 (PowerGood) 4 (/KLOCK) 5 (KDATA) 6 (KCLK) 7 (GND) 8 (+ 5V) 9 (VBAT) 3 5 2 4 1 Serial Port COM 1, 2 (RS232C) Pin Signalname In / Out DSUB-25 (need.
MOPS/586 Peripheral Interface Parallel Port LPT 1 Pin Signalname Function In / Out DSUB-25 (need Adapter) 1 /Strobe Out 1 3 Data 0 I/O 2 5 Data 1 I/O 3 7 Data 2 I/O 4 9 Data 3 I/O 5 11 Data 4 I/O 6 13.
IDE Connector for 2,5" Hard Disk Pin Signal Pin Signal 1 /RESET 2 GND 3 D7 4 D8 5 D6 6 D9 7 D5 8 D10 9 D4 10 D11 11 D3 12 D12 13 D2 14 D13 15 D1 16 D14 17 D0 18 D15 19 GND 20 NC 21 NC 22 GND 23 /.
MOPS/586 Peripheral Interface Power Connector Pin Pin function 1 GND 2 +5V 3 keypin 4 +12V 5 -5V 6 -12V 7 GND 8 +5V Power Pins The MOPS/586 is a +5 V only module. Nevertheless the power connector offers the possibility to supply with the additional voltages +12V, -12V and -5V which may be needed by other boards in the PC/104 system.
MOPS/586 Peripheral Interface PC/104-Connector Specification XT Bus Pin Signal Name Pin Signal Name A1 /IOCHCK B1 GND A2 SD7 B2 RESETDRV A3 SD6 B3 +5V A4 SD5 B4 IRQ9 A5 SD4 B5 -5V A6 SD3 B6 DRQ2 A7 SD.
MOPS/586 Literature, Standards, Links Literature, Standards, Links PC/104-Bus • PC/104 Specification Version 2.3 June 1996 PC/104 Consortium; www.pc104.
MOPS/586 Document Revision History Document Revision History Filename Date Edited by Alteration to preceding revision P488M210 10.09.98 KW Created P488M211 16.09.98 KW Add SSD P488M212 28.09.98 KW Onboard-DRAM, superMOPSpro replaced P488M213 10.01.99 KW Add L1-Cache P488M214 22.
Een belangrijk punt na aankoop van elk apparaat Tri-M Systems MOPS/586 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Tri-M Systems MOPS/586 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Tri-M Systems MOPS/586 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Tri-M Systems MOPS/586 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Tri-M Systems MOPS/586 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Tri-M Systems MOPS/586 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Tri-M Systems MOPS/586 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Tri-M Systems MOPS/586 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.