USSC 1 851621E MUL TIFUEL ST OVE 6039, 6039I, 6039T OWNER’S MANUAL Installation - Operation - Maintenance Instructions - Repair Parts READ THIS ENTIRE MANUAL , THOROUGHL Y , BEFORE A T TEMPTING T O INST ALL AND/OR BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MUL TI-FUEL ST OVE.
2 USSC Heat Input, Maximum 52,200 BTU/HR Heat Output, Maximum , , , , , 48,280 BTU/HR Heating Capacity 1,200 Sq. Ft 0 Fuel Storage Capacity 60 Lbs. Width 29 in.
USSC 3 ASSEMBLY Assembly 1. Unpack unit and make sure all components are included; (4) Legs, and all hardware for installation. 2. Fold the corner padding from the carton and lay it on the floor behind the unit. This is used to hold the heater up off the floor to install the legs.
4 USSC 6039I ASSEMBLY For the following assemblies, we suggest locating the unit near it’s desired location. Depending on installation, you may want to connect the exhaust venting before installing the facade parts.
USSC 5 COMPONENT LOCATION.
6 USSC Ashes will have to be removed from the stove for proper operation. See cleaning procedure. Y our American Harvest sto v e, due to the natur e of sol id f uels, wi l l r equir e brief periodic at tention. Please do not expect to light your stove and walk away from it.
USSC 7 FLOOR PROTECTION The American Harvest Multifuel Stove may be installed on a combustible floor , with proper floor protection, or on a masonry hearth. The hearth or noncombustible floor protector must extend a minimum of (6) inches (152mm)in front and (6) inches (152mm) from each side of the unit.
8 USSC CLEARANCES TO COMBUSTIBLES 6039(T) The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE: These are minimum clearances to combustible walls established by the testing lab. PARALLEL - A - Sidewall to T op Edge of Unit 8 in.
USSC 9 CLEARANCES TO COMBUSTIBLES 6039I.
10 USSC GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN • • • • • • • • A UL listed 3” or 4” type “PL ” pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove.
USSC 11 For installations with horizontal through-the-wall exhaust, it is strongly recommended that the stove combustion air be connected to the outside. If the home is newer or has been tightly insulated, it is required to install outside combustion air .
12 USSC Note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA -B365 The American Harvest Multifuel Stove Model 6039/6039T m.
USSC 13 3" PL Vent (12" Long) Inner Wall Thimble Outer Wall Thim ble 3" PL Vent (12" Long) 3" PL Tee w/ Cleanou t 3" PL Vent (12" Long) 3" PL Ve nt 90° Elbow 3.
14 USSC THROUGH THE WALL, VERTICAL PIPE INSTALLATION WITH TERMINATION CAP The Hearth Pad is not required under the unit if the floor is noncombustible but is required 6 inches (152mm) beyond the front of the unit and 6 inches (152mm) bey ond each side of the door if the floor is a combustble floor .
USSC 15 DESIGN GUIDELINES FOR 6039I INSERT INSTALLATION INSTALLATION AS A BUILT-IN FIREPLACE A continuous sheet of non-combustible floor protection must be installed underneath the unit to prevent the possibility of embers falling through to the combustible floor .
16 USSC DESIGN GUIDELINES FOR 6039I INSERT INSTALLATION INSTALLATION INTO A MASONRY FIREPLACE When installing into a masonry fireplace, DO NOT remove an y bricks or masonry , with the following except.
USSC 17 Y our American Harvest Multifuel Stove comes to you wi th the glass door instal led in place, ready f or use. The glass is surrounded on the edges with a gasket and seated in a glass channel. It is held in place with two (2) clips. REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS Open the door and lift off of hinges.
18 USSC UNDERSTANDING THE CONTROL BOARD CONTROL PANEL T urning the heater OFF/ON, as well as adjustments for the fuel feed rate and room fan speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower left-hand side of your American Harvest heater.
USSC 19 LIGHTING INSTRUCTIONS CAUTION: DO NOT USE CHEMICALS OR FLUIDS T O ST ART THE FIRE HOT WHILE IN OPERA TION. KEEP CHILDREN, CLO THING AND FURNITURE AW AY . CONT ACT MA Y CAUSE SKIN BURNS. Before lighting your heater for the first time, make sure that all items are out of the hopper, ash pan and firebox area.
20 USSC SPECIAL CLEANING/OPERATIONAL INSTRUCTIONS: After cleaning or when operating the stove, you need to make sure that “both” clean-outs are in their proper position. If left out or placed incor- rectly , the combustion air is eff ected greatly and the stove will not burn properly .
USSC 21 FUEL ADDITIVE Chicken Scratch for my Corn Burner? Y es - Crazy as it may sound, ground Oyster Shells, (calcium carbonate) same as fed to chickens, is the ideal additiv e to promote clean burning, especially when the Corn Fuel is extra high in starch.
22 USSC CIRCUIT BOARD FUNCTIONS Draft Fan Agitator Auger Room Fan Automatic Shutdown Normal Operation COMPONENT OPERA TION ST ART OPERA TION END ST ART -UP SEQUENCE OF EVENTS Once the control panel is turned to on, a timer begins that will start, stop and continue operation of the American Harvest as a preset temperature is achieved.
USSC 23 ERROR CODES and DISPLAY INDICATORS CAUTION: When performing any internal electrical maintenance • Moving parts inside of the cabinet may cause injury . Do not oper ate unit with panels remov ed or open. • HOT parts. Do not operate the unit with panel open.
24 USSC TROUBLE SHOOTING NOTE: Negative pressure in a home is a serious issue. All American Harvest appliances should be installed with the optional fresh air kit (69F AK). Unplug stove before performing any maintenance PROBLEM CAUSE: T oo rich air/fuel mixture ? Fire burns with a lazy , orange flame and/or fuel builds up in the firepot.
USSC 25 WIRING DIAGRAM.
26 USSC REPAIR PARTS DIAGRAM-6039.
USSC 27 K EY PAR T # DESCRIPTION QTY. 1 69516 Feed Door Assembly 1 2 25080MB Latch, Door 1 3 25409MB Pedestal (6039) 1 4 69508MB Pedestal Bottom Weldment (6039) 1 5 25451MB Pedestal Back (6039) 1 6 69.
28 USSC 22 23 20 21 24 25 26 27 18 17 7 6 3 4 6 5 11 10 2 9 8 10 15 14 16 12 13 19 23 1 28 29 REPAIR PARTS-6039I.
USSC 29 K EY PA RT # DESCRIPTION QTY. 1 891373 Pad, Door Hinge(Threaded) 2 2 69547MB Weldment, Sub-Base 1 3 25569 Bracket, Caster 2 4 891424 Caster , Plastic 2 5 83412 1/4-20 x 1-1/2 Hex Bolt 2 6 8313.
30 USSC K e y Part No. Descritption Qty. 1 25523 Leg, Cast Iron 4 1 a 891216 Leg, Steel (alternate to item 1) - 2 25425 Guide Rail, Ash Pan 2 3 69483B Ash Pan Weldment 1 4 891138 Handle, Brass 1 1 3 2 4 5 6 7 9 10 8 11 2 3 1 6 4 5 K e y Part No. Descritption Qty.
USSC 31 Notes.
32 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND- ABLE SERVICE FROM YOUR AMERICAN HARVEST, AND EN- ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER- ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Een belangrijk punt na aankoop van elk apparaat United States Stove 6039I (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen United States Stove 6039I heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens United States Stove 6039I vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding United States Stove 6039I leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over United States Stove 6039I krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van United States Stove 6039I bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de United States Stove 6039I kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met United States Stove 6039I . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.