Gebruiksaanwijzing /service van het product 36XDV van de fabrikant Vermont Casting
Ga naar pagina of 56
DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building.
XD V Direct V e nt G as Fir eplace 2 10009383 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
10009383 3 XD V Direct V e nt G as Fir eplace This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code.
XD V Direct V e nt G as Fir eplace 4 10009383 Ref. 33XDV 36XDV 39 XDV A 33” (838 mm) 36” (914 mm) 39” (991 mm) B 28 ⁷⁄₈ ” (733 mm) 34 ¹⁄₄ ” (870 mm) 34 ¹⁄₄ ” (870 mm) C 31 .
10009383 5 XD V Direct V e nt G as Fir eplace 5/ 8 " V - R oug h O pe nin g W idt h 7" Dia. 4" Dia. Rough Opening Height Rough Opening Depth Recessed Nailing Flange (178mm) (102mm) (16m.
XD V Direct V e nt G as Fir eplace 6 10009383 T op of Unit to Ceiling ................................ 36” (914 mm) Front of Unit to Combustibles ................... 36” (914 mm) Appliance T op of Standoff .........................................
10009383 7 XD V Direct V e nt G as Fir eplace Max. Min. Inp ut Input Model Fuel Gas Control BTU/ h BTU/h 33XDVRN Nat. Millivolt Hi/Lo 21,500 4,400 33XDVRP Prop. Millivolt Hi/Lo 21,500 5,425 33XDVEN Nat. 24 V olt Hi/Lo 21,500 4,400 33XDVEP Prop. 24 V olt Hi/Lo 21,500 5,425 36XDVRN Nat.
XD V Direct V e nt G as Fir eplace 8 10009383 The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe or an ap- proved flex connector . Since some municipalities have additional local codes, it is always best to consult your local authority and the National Fuel Gas Code, ANSI Z223.
10009383 9 XD V Direct V e nt G as Fir eplace The EB-1 Electrical junction box has been fitted stand- ard on this model to allow for the easy connection of an optional fan kit. T o connect the EB-1 box to the house electrical supply follow the steps below .
XD V Direct V e nt G as Fir eplace 10 10009383 Optional T op V ent Application The 33/36/39XDV fireplaces are shipped as rear vent units. If the layout requires a top vent, convert the unit following the steps below . 1. Remove the 10 screws securing outer collar adapter to fireplace.
10009383 1 1 XD V Direct V e nt G as Fir eplace T op V ent Application Restrictor Plate When the 33XDV or 36XDV models are installed as top vent fireplaces with a minimum 12” (305 mm) rise, the restrictor plate must be installed to give better flame appearance.
XD V Direct V e nt G as Fir eplace 12 10009383 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Fixed Closed Operabl e Operable Fixed Closed V B CFM145a DV Termin Location 5/01/01 Rev.
10009383 13 XD V Direct V e nt G as Fir eplace Fig. 17a T ermination clearances. General Information Assembling V ent Pipes Canadian Installations: V enting system must be installed in accordance with the current CSA-B149.
XD V Direct V e nt G as Fir eplace 14 10009383 The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall.
10009383 15 XD V Direct V e nt G as Fir eplace DVR584-600 Rear vent no elbows 2/99 djt 20" (508 mm) Rear V ent T op View DVR584-600 Fig. 21 Rear vent application, no elbows. FP836 Rear V ent-T op V iew 1 1/21/98 20" (508 mm) Max. REAR VENT -TOP VIEW 20" (508 mm) Max.
XD V Direct V e nt G as Fir eplace 16 10009383 FP1005 Side View V ent T ermination 1/25/00 djt Finished W all V ent T ermination FP1005 Fig. 25 Side view of final unit location. Rear W all V ent Installations - Flex V ent Pipe Follow Steps 1 and 2 on Page 15.
10009383 17 XD V Direct V e nt G as Fir eplace • The maximum number of 90° elbows per side wall installation is three (3). (Fig. 28) • If a 90° elbow is fitted directly on top of the fireplace flange, the maximum horizontal vent run before the termination or a vertical rise is 36” (914 mm).
XD V Direct V e nt G as Fir eplace 18 10009383 V ertical Sidewall Installation T wist Lock Pipe STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size.
10009383 19 XD V Direct V e nt G as Fir eplace STEP 7 Apply high temperature sealant to 4” (102 mm) and 7” (178 mm) collars or the termination one inch away from the end. Guide the vent termination’s 4” and 7” collars into their respective vent pipes.
XD V Direct V e nt G as Fir eplace 20 10009383 Below Grade Installations When it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level a snorkel kit is recommended. This allows installation depth of down to 7” (178 mm) below grade level.
10009383 21 XD V Direct V e nt G as Fir eplace Max. Height 40’ (12.2m) Min. Height 8’ (2.4m) Max. 10’ (3m) Support Straps Every 3’ (.9m) Max. Height 40’ (12.2m) Min. Height 8’ (2.4m) Max. 10’ (3m) FP1 183 Fig. 41 Support straps for horizontal runs.
XD V Direct V e nt G as Fir eplace 22 10009383 FP1184 T ypical roof/ceiling suppor t apps. T ypical Roof Support Application T ypical Ceiling Support Application Fig. 44 V enting supports. FP1 184 Min. 2' (610 mm) FP1 185 Fig. 45 Minimum termination to roof clearance.
10009383 23 XD V Direct V e nt G as Fir eplace 7TDVRVT - Through the wall Rear V ent T ermination Starter Kit - Model 7TDVSK - Sidewall V enting (T wist Lock Pipe) Model 7FDVSK - Sidewall V enting (Fl.
XD V Direct V e nt G as Fir eplace 24 10009383 Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass.
10009383 25 XD V Direct V e nt G as Fir eplace Log Center Right (A51) LG955 Figure 51 Installation of Logs The logs are fragile and should be handled with care.
XD V Direct V e nt G as Fir eplace 26 10009383 36XDV 4. Place the log front (A50). Place the two underside holes of the log over the two pin studs of the bracket located at the front of the burner housing. (Fig. 52) 5. Place the log top right (A52). Place the bot - tom round hole onto the knob at the right side of the rear log.
10009383 27 XD V Direct V e nt G as Fir eplace Log Front (B155) LG950 Figure 56 2. Place the log, center right (B153). Place the two underside holes of the log over the two pin studs of the bracket support center log on the right.
XD V Direct V e nt G as Fir eplace 28 10009383 NOTE: Refer to Figure 57 for bracket and bend loca- tions. 1. Place the log front right. Hold the log with the pointed end toward the left.
10009383 29 XD V Direct V e nt G as Fir eplace Log Rear LG467 Figure 62 3. Place log rear . The rear log sits in the firebox at an angle toward the left over the rear log bracket and the left side of the burner .
XD V Direct V e nt G as Fir eplace 30 10009383 Large Lava Rock The large bag of lava rock provided with this fireplace must be placed on the firebox base around the sides of the burner assembly and on the tray beneath the grate. Under no circumstances should this large lava rock be placed on any part of the burner assembly .
10009383 31 XD V Direct V e nt G as Fir eplace Fig. 69 Correct burner flame appearance. Y ellow Flames Red Glow LG959 Y .
XD V Direct V e nt G as Fir eplace 32 10009383 3. Open louvre assembly bottom. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace.
10009383 33 XD V Direct V e nt G as Fir eplace Lighting & Operating Instructions For Fireplaces equipped with SIT822 Gas V alve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
XD V Direct V e nt G as Fir eplace 34 10009383 Instructions for RF C om fo rt C o nt ro l Va l ve The Comfort Control V alve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal.
10009383 35 XD V Direct V e nt G as Fir eplace Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key . Pushing the key once will change the timer by 10 minutes.
XD V Direct V e nt G as Fir eplace 36 10009383 LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 T urn fan ON NOTE: Some keys are not active.
10009383 37 XD V Direct V e nt G as Fir eplace Light pilot burner Set manual switch to local or remote Release pilotstat knob T urn pilotstat knob from PILOT to ON If manual switch is set to LOCAL, di.
XD V Direct V e nt G as Fir eplace 38 10009383 NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. SIT NOV A 820 MILLIVOL T V AL VE T roubleshooting the Gas Control System W ARNING: REMOVE GLASS FRONT BEFORE DOING ANY GAS CONTROL SERVICE WORK.
10009383 39 XD V Direct V e nt G as Fir eplace T roubleshooting the Gas Control System SIT 822 V alve with Synetek Electronic Control Operating Diagram Normal Operation ON/OFF Switch Closed? Safe Star.
XD V Direct V e nt G as Fir eplace 40 10009383 Fuel Conversion Instructions T o convert the XDV units for use with a different gas fol- low these instructions. Before proceeding, turn control knob on valve to “ OFF ” and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance.
10009383 41 XD V Direct V e nt G as Fir eplace LP: Rear air shutter fully open. Front air shutter fully open. 7. Reinstall burner housing assembly and front burner tube.
XD V Direct V e nt G as Fir eplace 42 10009383 Fuel Conversion Instructions Honeywell Comfort Control V alve ONL Y W ARNING: The conversion must only be undertaken by a qualified, certified gas ap- pliance installer .
10009383 43 XD V Direct V e nt G as Fir eplace CO103 Gas Conv ersion Air shutter 2/15/99 djt Fig. 86 Remove air shutter from burner pan. Shutter Retaining Screw Burner Pan Air Shutter Front View CO103 5. Install conversion air shutters on burner pan.
XD V Direct V e nt G as Fir eplace 44 10009383 Conversion to Natural Gas Burner Orifice Input (BTU/hr) Kit # Model Front Part # Rear Part # Minimum Maximum 2001 1506 39XDVRP #53 20007347 #44 30000334 6,700 30,000 (.
10009383 45 XD V Direct V e nt G as Fir eplace Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
XD V Direct V e nt G as Fir eplace 46 10009383 38 1a 1f 1d 1 33XDV 2 3 13 19 32 21a,b 22a,b 26 27 24 25 28 HI LO 39 23a,b 31 45 48 46 49 47 51 52 53 61 LOCAL REMOTE ON • PILOT OFF • LED 40 59 33a,.
10009383 47 XD V Direct V e nt G as Fir eplace 33XDV/36XDV/39XDV (continued) Ref. Description 33XDV 36XDV 39XDV 1. Log Set (Complete) 10009399 10009367 20010991 1a. Log Rear 10009392 (A49) 10009361 (B152) 20010994 1b. Log Center Right 10009394 (A51) 10009362 (B153) -- 1c.
XD V Direct V e nt G as Fir eplace 48 10009383 33XDV/36XDV/39XDV (continued) Ref. Description 33XDV 36XDV 39XDV 33b. Orifice Pilot LP RF -- 20000907 n/a 34a. Pilot Assembly Nat. RF -- 20002266 n/a 34b. Pilot Assembly LP RF -- 20002268 n/a 35. Thermopile (RF) -- 20002400 n/a 36.
10009383 49 XD V Direct V e nt G as Fir eplace Optional Accessories A vailable FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth sup - ports.
XD V Direct V e nt G as Fir eplace 50 10009383 Remote Controls Optional remote control units are available to control dif- ferent functions of the appliance.
10009383 51 XD V Direct V e nt G as Fir eplace Optional T rim Kits Louvre Accent T rim Appliance Model Main Louvre Kit Additional Louvre Polished Brass 33XDV 33DVLMP 33DVLAP 36XDV 36DVLMP 36DVLAP 39XD.
XD V Direct V e nt G as Fir eplace 52 10009383.
10009383 53 XD V Direct V e nt G as Fir eplace.
XD V Direct V e nt G as Fir eplace 54 10009383.
10009383 55 XD V Direct V e nt G as Fir eplace BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 33XDVRN 60.1 80 81 64 33XDVRP 60.1 81 82 64 33XDVEN 66.2 80 81 64 33XDVEP 66.2 81 82 64 36XDVRN 61.8 83 84 64 36XDVRP 61.8 84 85 64 36XDVRFN 61.
Een belangrijk punt na aankoop van elk apparaat Vermont Casting 36XDV (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Casting 36XDV heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Casting 36XDV vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Casting 36XDV leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Casting 36XDV krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Casting 36XDV bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Casting 36XDV kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Casting 36XDV . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.