Gebruiksaanwijzing /service van het product 410 van de fabrikant Vermont Casting
Ga naar pagina of 28
Homeowner ’ s Installation and Operating Manual For use in the United States and Canada SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
2 Madison Woodburning Stove 30001453 Introduction Thank you for choosing a Vermont Castings Madison to meet your heating needs. We're confident you will find the Madison to be an effective woodburning heater incorporating modern, non-catalytic combustion technology with the classic aesthetic appeal of its Vermont Castings lineage.
3 Madison Woodburning Stove 30001453 Specifications Madison, Model 1655 Series Range of Heat Output ............... 1 1,300 - 39,700 BTU’ s Maximum heat output ......................... 39,700 Btu’s/hr . 1 Area heated .............................
4 Madison Woodburning Stove 30001453 Chimneys Y our stove must be connected either to a sound masonry chimney that meets local codes, to a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney . Whichever of those types you use, the chimney and chimney con- nector must be in good condition and kept clean.
5 Madison Woodburning Stove 30001453 Masonry Chimneys, cont'd. • Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Openings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement.
6 Madison Woodburning Stove 30001453 Double-wall Chimney Connectors The Madison is approved for installation in the U.S. and Canada with double-wall chimney connectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory .
7 Madison Woodburning Stove 30001453 Connection Above the Fireplace In this installation, the chimney connector enters the fireplace flue through a thimble located above the fireplace. (Fig. 6) The liner of the fireplace chimney should extend at least to the point at which the chim- ney connector enters the chimney .
8 Madison Woodburning Stove 30001453 Floor Protection A tremendous amount of heat radiates from the bottom plate of your Madison. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox.
9 Madison Woodburning Stove 30001453 To meet these requirements, a floor protector must be at least 54” (1372mm) wide (“A”,Fig. 12) and 52” (1320mm) deep (“B”, Fig. 12). Fireplace Hearth Protection Do not assume that your fireplace hearth is completely noncombustible.
10 Madison Woodburning Stove 30001453 Wall Shields W all shields should be constructed of 24 gauge or heavier sheet metal, or another noncombustible material such as 1/2" (13mm) insulation board (Fig. 14) or common brick "laid on flat," with the 3 ¹⁄₂ " (89mm) side down.
11 Madison Woodburning Stove 30001453 Alcove Installations Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations.
12 Madison Woodburning Stove 30001453 Madison 1655 Series Clearance Chart Use the chart below together with the diagrams on the next page to determine the minimum clearance required for your particular installation.
13 Madison Woodburning Stove 30001453 F F C C A B D E J K L L G H P Q M N I I O O R R V W S T U U X X Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner .
14 Madison Woodburning Stove 30001453 Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner PROTECTED SURFACES Madison 1655 Series Clearance Diagram UNPROTECTED SURFACES Rear Exit Installations, Bottom Heat Shield, floor protection, minimum 18” (457mm) in front.
15 Madison Woodburning Stove 30001453 Y ou will need the following tools to assemble the Madi- son: • 9/16" open end wrench • safety glasses & gloves • flat head screwdriver • power drill w/ 1/8" (3mm) bit • stub handle phillips screwdriver Unpack the Stove 1.
16 Madison Woodburning Stove 30001453 Attach the Chimney Connector Insert the crimped end of the first section of chimney connector into the flue collar . Using the holes in the collar as guides, drill 1/8" (3mm) holes through the connector pipe.
17 Madison Woodburning Stove 30001453 How the Madison Works Combustion control is achieved in the Madison through two separate air delivery systems. The primary air control lever , located at the left rear corner of the stove, controls the amount of incoming primary air for starting, maintaining, and reviving the fire.
18 Madison Woodburning Stove 30001453 Fig. 27 Start a fire with small, dry kindling. ST263 Fig. 28 Gradually add larger pieces of wood until all the wood is burning well. ST264 In newer homes that are well-insulated and weather- tight, poor draft may result from insufficient air in the house.
19 Madison Woodburning Stove 30001453 NOTE: Some chimneys need to be “primed,” or warmed up, before they will draw sufficiently to sustain a fire. T o correct this situation, roll up a couple pieces of newspaper , place them on top of the kindling and toward the back of the stove, light them, and close the doors.
20 Madison Woodburning Stove 30001453 Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Madison looking new.
21 Madison Woodburning Stove 30001453 The Chimney System Creosote Your Madison is designed to reduce creosote buildup significantly. However, regular chimney inspection and maintenance must still be performed.
22 Madison Woodburning Stove 30001453 Your stove is only one part of a system that includes the chimney, the operator, the fuel and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the stove works well.
23 Madison Woodburning Stove 30001453 There should be no more than eight feet of single-wall stove pipe between the stove and a chimney . Longer runs can cool the smoke enough to cause draft and creosote problems. Use double-wall stove pipe for longer runs.
24 Madison Woodburning Stove 30001453 1453 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
25 Madison Woodburning Stove 30001453 Madison W oodburning Stove Model 1655, 1656, 1657, 1658, 1659 (continued) Item Description Part Number 23. Brick Support 30000804 24. Secondary Air Tube (Rear) 30001493 25. Secondary Air Tube (Middle) 30001494 26.
26 Madison Woodburning Stove 30001453 Shell Enamel Parts - Madison Model 1655 Part Name Classic Green Moonlight Sand Red Suede Brown To p 30000817 30001213 3001203 30001 193 30001 183 30002599 Left Si.
27 Madison Woodburning Stove 30001453 W arranty Limited 3 Y ear W arranty CFM Specialty Home Products warrants that this woodburning stove will be free of defects in material and workmanship for a per.
© CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.
Een belangrijk punt na aankoop van elk apparaat Vermont Casting 410 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Casting 410 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Casting 410 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Casting 410 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Casting 410 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Casting 410 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Casting 410 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Casting 410 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.