— Do not store gasoline or other flammable vapors or liquids near this or any other appliance. — WHA T T O DO IF Y OU SMELL GAS • Do not try to light any appliance. • Do not touch an y electrical switch; do not use any phone in y our building.
2 20003889 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read these directions thoroughly before installation. For assistance or additional infor- mation, consult your gas log dealer , qualified installer , service agency or gas supplier .
20003889 3 The Logsets have been designed and tested to operate safely when installed according to the installation instructions contained in this manual. Read all instructions before starting the installation. • The logset should be inspected before use and at least annually thereafter .
4 20003889 CA UTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Are you burning Natural Gas? If you have Propane Gas, you need to purchase a factory authorized safety pilot kit (see below).
20003889 5 This Damper Stop is designed to work on all CFM Specialty Home Products BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6. When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close completely .
6 20003889 The Damper Stop provided keeps your damper from accidentally closing during operation of your set. This Damper Stop must be installed onto your Damper at all times . NOTE: The damper clamp is designed to hold the damper plate open 3 inches.
20003889 7 Leak T est Pr ocedures Create a mixture of equal parts soap and water . Apply to all the joints of the pipe fittings from the gas supply pipe to the burner . T urn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak.
8 20003889 1. Place the Elevated Grate Steps onto the back of the Grate and attach the Fettel to front of Grate as shown in Figure 7. 2. Place the Grate over the Burner Pan so the front legs of the Grate are 1” behind the front edge of the Pan, as shown in Figure 8.
20003889 9 1. T urn the gas shut-of f valve to OFF . 2. W ait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information above. If you don’t smell gas, go on to the next step. 3. Light a match and lay it on top of the pan material, about 2” from the end of the supply side of the pan.
10 20003889 Tr oub leshooting Log Set is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flame contacts the logs.
20003889 11 8 11 7 5 4 2 3 17 13 18 16 14 19 10 12 15 9 6 1 a b c d e f g h CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. R18 / 24 / 30CFL V ented Gas Logs 1.
12 20003889 R18 / 24 / 30CFL V ented Gas Logs (continued) Ref. Description R18CFL R24CFL R30CFL 11 . Cast Front Grate w/Clips CIGF18 CIGF24 CIGF30 12. Grate 20000924 20000925 20000926 13. Grate Step 20000955 20000955 20000955 14. Pan & Extension Assembly 20003840 20003841 20003842 15.
20003889 13 W ARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W ARRANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EX- PRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Pr oducts.
Een belangrijk punt na aankoop van elk apparaat Vermont Casting R30CFL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Casting R30CFL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Casting R30CFL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Casting R30CFL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Casting R30CFL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Casting R30CFL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Casting R30CFL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Casting R30CFL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.