Gebruiksaanwijzing /service van het product VGBQ412T van de fabrikant Viking
Ga naar pagina of 16
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA.
IMPORTANT: PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty • Please observe all local and national codes and ordinances.
BASIC SPECIFICATIONS T-SERIES GRILLS Description Cutout Width Cutout Depth Cutout Height Overall Width Overall Depth Gas Requirements Electrical Requirements Grill Burner Rating TilJSea r TM Burner Ra.
BASIC SPECIFICATIONS E-SERIES GRILLS Description Cutout Width Cutout Depth Cutout Height Overall Width Overall Depth ,Sas Requirements Electrical Requirements Maximum Amp Usage Still Burner Rating Tru.
GAS CONNECTION Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the grill rating plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-off valve must be installed in an easily accessible location.
NATURAL FIXED PIPING CONNECTION Connection: Operating Pressure: Supply Pressure: Standard Residential 1/2" ID gas service line - 1/2" NPT male with 7/8" (2.2 cm) flare adapter. 4.0" W.C.R Nat. 6" to 10" W.C.R Nat. If in excess of 10" W.
LP/PROPANE FIXED PIPING CONNECTION Connection: Operating Pressure: Supply Pressure: Standard Residential 1/2" ID gas service line - 1/2" NPT male with 3/8" flare adapter. 10.0" W.C.R LP/Propane. 11" to 14" W.C.R Nat. If in excess of 14" W.
LP/PROPAN E TAN K CON N ECTION Outdoor grills orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb.
LEAK TESTING Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation clue to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit.
INSTALLATION PROCEDURES FOR BUILT-IN INSTALLATION 1. A minimum of 6" (15.2 cm) from the sides, or a minimum of 8" (20.3 cm) from the right side if there is a rotisserie motor, and a minimum of 24" (61.0 cm) from the back must be maintained from the grill above the cookin 9 surface to adjacent vertical combustible construction.
,, (15.2 cm) / / ._ A ,. n 0 0 _° o /, o°@ @0 / / / / MODEL Dim. A VGBQ300T/0302T 29 1/2" (74.9 cm) VGBQ300E VGIQ300T 29 1/2" (74.9 cm) VGIQ300E VGBQ410T/VGIQ410T 41 3/16" (104.6 cm) VGBQ410E/VGIQ410E VGBQ412T 41 3/16" (104.6 cm) VGBQ412E VGBQ530T/VGIQ530T 53 3/16" (135.
CUTOUT DIMENSIONS Model Dim. B VGBQ300T/0302T 28 518" (72.7 cm) VGBQ300E VGIQ300T 28 5/8" (72.7 cm) VGIQ300E VGBQ410T/VGIQ410T 40 1/4" (102.2 cm) VGBQ410E/VGIQ410E VGBQ412T 40 1/4" (102.2 cm) VG BQ412E VGBQ530TNGIQ530T 52 1/4" (132.
BURNER ADJUSTMENT Each burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make it necessary to adjust the burners. The flames of the burners (except the rotisserie infrared burner) should be visually checked and compared with Fig.
Fig. 3 SIDE BURNERS (If applicable) °O o _[ ° I -1_ Air Shutters / Orifice Fig. 4 FLAME HEIGHT SIDE BURNERS (If applicable) 3/8" (.95 cm) Fig. 6 FLAME HEIGHT TruSear BURN ER 1/4" (.64 cm) Fig. 5 FLAME HEIGHT INFRARED BURNER 1/4" (.64 cm) .
ROTISSERIE SYSTEM The rotisserie motor is attached to the mounting bracket located on the right side of the grill frame. The rotisserie motor must be electrically grounded in accordance with local cod.
F20054H (PSO606VR).
Een belangrijk punt na aankoop van elk apparaat Viking VGBQ412T (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Viking VGBQ412T heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Viking VGBQ412T vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Viking VGBQ412T leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Viking VGBQ412T krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Viking VGBQ412T bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Viking VGBQ412T kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Viking VGBQ412T . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.