Gebruiksaanwijzing /service van het product xStream van de fabrikant Vita Spa
Ga naar pagina of 30
DM INDUSTRIES, LTD. 2320 N.W . 147th Street Miami, Florida 33054 www .dmindustries.com health and relaxation for life IMPORTANT SAFETY INSTRUCTIONS READ ENTIRE MANUAL BEFORE INSTALLING SPA.
09D12345BTZ P817G2DC1 17ACB 09D12345BTZ P817G2DC1 17ACB L I S T E D C US CONFORMS TO ANSI/UL STD 1563 CERTIFIED T O CAN/CSA C22.2 STD NO.218.1 DM Industries, L TD. 2350 N.W . 147 Street Miami, FL 33021 (305) 685-5739 www.dmindustries.com Serial Number Model Number ID PL ATES ARE L OCATED IN THE FRONT OF THE SP A .
OWNER’S RECORD D ATE PUR CHASED: ________________________________________ D ATE INST ALLED: _________________________________________ DEALER : __________________________________________________ ADDR.
.
GENERAL INFORMATION • Important Safety Instructions . . . . . . . . . . . . . . 1 • Manufactur er’s Do’s and Don’ts . . . . . . . . . . . . 2 SET UP AND INSTALLATION • Set Up and Installation Instructions. . . . . . . . . . 2 • W arning Label Installation .
.
PAGE 1 IMPORTANT SAFETY INSTRUCTIONS WHEN INST ALLING AND USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD AL W AYS BE FOLLOWED, INCL UDING THE FOLL OWING D ANGERS: 1. WARNING - T o reduce the risk of injury . Do not permit children to use this pr oduct unless they are closely supervised at all times.
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal HYPERTHERMIA. PAGE 2 R eading and understanding these warnings will allow you to r educe the risk of causing inadvertent damage to your spa, your surroundings, or yourself .
PAGE 3 INST ALLING THE SP A COVER 1. P osition the cover squarely over the spa. 2. P osition the locks for the tie-downs on the sides of the spa. Y ou should allow appro ximately 13mm to 20mm (1/2” to 3/4”) slack in the straps for ease of insertion into the locks and to allow for material shrinkage during temperatur e changes.
817G2 817G1 817G3 (2 ea) 0212318 (2 ea) 0532064 Cascade Cover Plate 0663005 (1 ea) 0212305- TRB (2 ea) 0532064 (1 ea) 0212318 (2 ea) 0212318 DRAIN DRAIN DRAIN DRAIN PAGE 4 NO DIVING TILES.
NOTE: FOR BEST RESULTS, READ EACH STE P CAREFU LLY AND ENTIRELY BEFORE PROCEEDING TO THE NEXT. FILLING YOUR SPA Wipe the interior of the spa with a damp, soft cloth to remove any residue that may be on the surface.
xStream Duo Pro only THERAPY OPERATIN G INSTRUCTIONS The xStream Duo Pro spa has been designed for your maximum enjoyment and comfort, with two totally independent areas, one for swi mming exercises and one for therapy. It has also been engi neered for energy effici ency.
3s TO START SELF TEST TO CANCEL SELF TEST continues on next p a g e Turns filtration On/Off on shown hour. 12: - Off 12: F Filtering Cycles up through filtration hours USE ARROWS TO CHANGE BETWEEN MOD.
TO CHANGE TO INDIVIDUAL DAYS OF THE WEEK: 7 – Saturday 6 – Friday 5 – Thursday 4 – Wednesday 3 – Tuesday 2 – Monday 1 – Sunday continues on next p a g e USE ARROWS TO CHANGE TEMPERATURE .
8s GOES BACK TO THE BEGINNING OF THE ADVANCED SET TINGS THERAPY ADVANCED P ROGRAMMING INSTRUCTIONS DO NOT ENTER THI S SECTION UNLESS IN STRUCTED BY A QUALIFIED TE CHNICIAN * * IMPROPER CHANGES MAY CAU.
SWIM OPERATING IN STRUCTIONS The xStream Series spas have been designed for your maximum enjoyment and comfort. They have been engineered for energy effi ciency, and the ICS TM electr onic contr ol center a llows full pr ogramming of temperature and filtration cycles.
SWIM OPERATING IN STRUCTIONS SETTING TEMPERATURE FOR A DAY. Press this button to display water temperature. Press these buttons to select the desired temperature. NOTE: For full instructions on programming your ICS TM controller, go to the SWIM PROGRAMING INSTRUCTION section on page 13.
SWIM OPERATING IN STRUCTIONS TURNING ON THE LIGHT Standard Light: Press to turn light on and off. LED Light : Press once to turn underwater lights on. Pressing a second time will turn on Aquabrite/ Chromatherapy, if so equi pped. Pressing a third time will turn lights off.
TO CHANGE TO INDIVIDUAL DAYS OF THE WEEK: 7 – Saturday 6 – Friday 5 – Thursday 4 – Wednesday 3 – Tuesday 2 – Monday 1 – Sunday continues on next p a g e USE ARROWS TO CHANGE TEMPERATURE .
12/24 HOUR MINUTES MONTH DAY YEAR continues on next p a g e GOES BACK TO THE BEGINNING USE ARROWS TO CHANGE ± TO LOCK ² TO UNLOCK ± TO LOCK ² TO UNLOCK SWIM PROGRAMMING INSTRUCTIONS E. CLOCK AND CALENDAR SETTING ...................................
8s xStream xStream Pro xStream Duo Pro GOES BACK TO THE BEGINNING OF THE ADVANCED SET TINGS USE ARROWS TO CHANGE VALUE SWIM ADVANCED PROGRAMMING I NSTRUCTIONS DO NOT ENTER THI S SECTION UNLESS IN STRU.
PAGE 16 Y our xStr eam Swim Spa’s therapy section is designed with a unique jet system to allow you to select a wide variety of massage patterns. The following is a description o f the various types of jets and their operation you may use to tailor your spa to your specific massage needs.
PAGE 17 SAFETY FEATURES A. FREEZE PROTECTION If the temperature in the spa plumbing falls below 10°C (50°F), the water pump will turn on low speed and run for 30 seconds. Af ter 30 seconds, if the water is still at 10°C (50°F), the heater will turn on and raise the temperatur e 2°C (10 °F).
FILTER MAINTENANCE Y our Spa is designed with the most efficient top loading filtration system in the industry . F ilter maintenance is the most critical fac- tor in k eeping your spa water clean. TO CLEAN THE FILTER (NOTE: NEVER RUN THE SP A WITHOUT A FIL TER INST ALLED) R emove the skimmer bask et and the cartridge.
PAGE 19 WINTERIZING YOUR SPA Most Hot T ub enthusiasts will agree that there is no bet- ter time to enjoy their spa then in colder winter months. Although your Spa has been designed and engineered for year -round use in any climate, if you chose to leave it empty in the winter time, there ar e precautions you should tak e.
SYMPTOM Spa Inoperative MESSAGE FL O HILI ICE LS SS CP REL HC P1/P2/P3 F1/F2/F3/F4 BUS PAGE 20 DIAGNOSTIC & TROUBLESHOOTING Resetting Your Spa Lik e your PC at home, your spa electronics could get cor rupted by electrical surges and operate impr operly .
3s 8s USE ARROW KEYS TO CHANGE VALUE UP OR DOWN Rev. Date: 10/17/200 8 Self Test (2 min.) If display does not show AH or ECO, call a service tech . FACTORY DEFAULT SETTINGS DOMESTIC EXPORT To exit Pro g rammin g mode p ress Jet, Li g ht or Aux button, or wait 10 seconds .
3s 8s Self Test Function not applicable to Swim Packs. xStream Pro xStream Duo Pro xStream Setup Menu - ADVANCED SETTINGS DISCLAIMER: DO NOT ENTER THIS SECTION UNLESS INSTRUCTED BY A QUALIFIED TECHNICIAN.
.
© 2009 DM INDUSTRIES • ALL RIGHTS RESER VED • SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE DM Industries, Ltd., 2320 Northwest 147th Street, Miami, Florida 33054 Email: customercar e@dmindustries.com and techhelp@dmindustries.com www .dmindustries.
Een belangrijk punt na aankoop van elk apparaat Vita Spa xStream (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vita Spa xStream heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vita Spa xStream vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vita Spa xStream leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vita Spa xStream krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vita Spa xStream bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vita Spa xStream kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vita Spa xStream . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.