INSTALLATION & OPERATIONAL MANUAL GRD & GRC SERIES GAS FRYERS With KleenScreen PLUS ® Filtration Systems M O D E L S : 1 G R 4 5 D M L - 1 3 6 4 1 1 1 G R 4 5 C M L - 1 3 6 4 1 4 1 G R 6 5 D .
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -5- INSTALLATION Do not use the door or its handle to lift the fryer. Before installing the fryer, veri fy that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -6- CODES AND STANDARDS The fryer must be insta lled in accordance with: In the United States: State and local codes, or in t he absence of local codes, with: National Fuel Gas Code, ANSI-Z223.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -7- FLUE CONNECTION Make the flue connection as follows: Comply with Vapor Removal from Cooking Equipment , ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -8- After piping has been checked for leaks, fully purge gas pipes to remove air. GAS PRESSURES (ALL MODELS): The gas pressure should be set at 4” W.C. (W ater Column) (0.8 kPa) for natural gas and 10” W.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -9- In Australia, use only the caster suppl ied by the manufacturer for the fryer device. The fryer must be installed using a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -10- BEFORE FIRST USE Cleaning New units are wiped down at the fa ctory to remove an y visible signs of dirt, oil, grease, etc.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -11- BASIC FRYING INSTRUCTION Set the desired temperature and allow short ening to heat up to that temperature. Fry items that are the same size to ensure equal doneness. Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot shortening.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -12- TURNING ON THE FRYER Open the door to the fryer. Turn the power switch to the on position. Set temperature by turning the knob to the desired temperat ures. The burners will light automatically.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -13- Programming the Solid State Control.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -14- Programming the Computer Control.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -15- DRAINING THE TANK 1. Turn off fryer. 2. Insert the drain extension into t he drain valve. Tighten only hand tight. 3. Direct the drain spout into the container that you want to drai n the shortening into.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -16- 7. Press the TEMP button again and the gas burners will heat the solution. Bring the solution to a simmer only. A llow to stand for a few minutes. 8. Turn OFF the power to the fryer.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -17- KleenScreen Plus ® Filtration System Installation and Operational Manual for “DF” and “CF” Models GRD/CF 2GR45DF S.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -18- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS ® filtration system filters t he oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -19- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -20- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -21- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -22- Filtering Instructions for KleenScreen PLUS ® Fryers with Solid State Controls.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -23- Filtering Instructions for KleenScreen PLUS ® Fryers with Computer Controls.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -24- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the re turn line to run back into the filter pan. This will take about 30 seconds to complete.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -25- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drai n extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -26- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, cleani ng, and servicing the fry er. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying com pound from the tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -27- OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled.
Een belangrijk punt na aankoop van elk apparaat Vulcan-Hart 1GR85DF ML-136790 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vulcan-Hart 1GR85DF ML-136790 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vulcan-Hart 1GR85DF ML-136790 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vulcan-Hart 1GR85DF ML-136790 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vulcan-Hart 1GR85DF ML-136790 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vulcan-Hart 1GR85DF ML-136790 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vulcan-Hart 1GR85DF ML-136790 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vulcan-Hart 1GR85DF ML-136790 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.