SERVICE MANUAL For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit our website at www.vulcanhart.com F35628 (10-04) - NOTICE - This manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.
— 2 — F35628 (10-04) T ABLE OF CONTENTS GENERAL ............................................................................................................................... ......... 3 Introduction ..............................................
— 3 — F35628 (10-04) INTRODUCTION Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific. All models are equipped with 30,000 BTU/HR burners as standard equipment.
— 4 — F35628 (10-04) REMOV AL AND REPLACEMENT OF P ARTS COMPONENT LOCATION Figure A Bullnose Deflector Plate Heat Shield Control Plate Control Panel Grease Drawer Griddle Flame Switch Ignitor Modu.
— 5 — F35628 (10-04) CONTROL PANEL WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the two screws securing the control panel. One screw is located at each end of the control panel. 2 . Pull the control panel forward and disconnect the electrical connector near the right end.
— 6 — F35628 (10-04) POWER ON/OFF SWITCH WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the control panel. 2. Label and disconnect the wires to the power ON/OFF switch. 3. Squeeze the switch retainer and slide the switch out through the front of the control panel.
— 7 — F35628 (10-04) FLAME SWITCH WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the control panel. 2. Label and disconnect the wires to the flame switch. 3. Remove the two screws securing flame switch to control plate.
— 8 — F35628 (10-04) GAS BURNER WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the back panel. 2. Cut shipping tie from burner. 3. To remove the burner, reach through the back of the unit and lift the burner up over the guide screw then pull the burner out through the back of the unit.
— 9 — F35628 (10-04) PILOT WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. WARNING: SHUT OFF THE GAS BEFORE SERVICING THE GRIDDLE. 1. Remove control panel and heat shield for visual access of the pilot.
— 10 — F35628 (10-04) WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER AND FOLLOW LOCKOUT / TAGOUT PROCEDURES, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.
— 11 — F35628 (10-04) 2. Units for operation of natural or propane gas are also equipped with a factory preset pressure regulator with an outlet pressure of 5” W.C. (Water Column) for natural gas supply and 10” W.C. for propane gas supply, and should not require further adjustment.
— 12 — F35628 (10-04) COMPONENT DESCRIPTION Power Switch ON/OFF – Switch turns power ON or OFF. Ignition Control Module – Provides ignition spark. Turned on when ON/OFF switch is set to the ON position and turned off when flame switch closes. Burner On Lights – Illuminates to indicate burner is turned on.
— 13 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 24” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2.
— 14 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 36” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2.
— 15 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 48” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2.
— 16 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 60” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2.
— 17 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 72” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2.
— 18 — F35628 (10-04) TROUBLESHOOTING GUIDE SYMPTOM Indicator light fails to light when power ON/OFF switch is set to ON position Indicator light fails to go out when power ON/OFF switch is set to.
— 19 — F35628 (10-04) TROUBLESHOOTING GUIDE REMEDY Check operation of pilot valve Purge gas lines Check that gas supply is on Check and repair wire connection Check for obstruction or wrong size o.
FORM 35628 (10-04) PRINTED IN U.S.A..
Een belangrijk punt na aankoop van elk apparaat Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.