Gebruiksaanwijzing /service van het product SPER2 ML-52919 van de fabrikant Vulcan-Hart
Ga naar pagina of 12
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 INST ALLA TION & OPERA TION MANUAL SPER1 & SPER2 ELECTRIC FR YERS MODEL SPER1 ML-52918 SPER2 ML-52919 SPER0 Frymate ML-52920 FORM 30729 Rev.
— 2 — Installation, Operation and Care of MODEL SPER1 & SPER2 ELECTRIC FR YERS PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE GENERAL Your Vulcan fryer is produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance.
— 3 — INSTALLATION CODES AND STANDARDS Your Vulcan fryer must be installed in accordance with: 1. State and local codes. 2. The National Electrical Code, ANSI/NFPA No. 70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
— 4 — PL-40545-1 Power On Light High Limit Lights Temperature Controller Power Switch Trouble Light Fry / Melt Switch Heating Light OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS.
— 5 — POWER SWITCH — Controls electric supply to fryer (Optional - hood ventilator to interlock.) POWER ON LIGHT — Indicates when electric supply is on. TEMPERATURE CONTROLLER — Maintains frying temperature by controlling power supply. HEATING LIGHT — When on, indicates temperature control is calling for power to the elements.
— 6 — Split Vat 1. Remove crumb screens. 2. Divide a 50-pound block of shortening into two equal halves (approximately 25 pounds each). 3. Place each half of the shortening directly on the heating elements in each well of the fry tank and slide back.
— 7 — PL-40547-1 Drain Valves Drain Nipple 1. Allow shortening to cool before draining or filling. 2. Consult the operating instructions supplied by the manufacturer of your filtering system before filtering the shortening. 3. Firmly screw the fryer drain nipple (supplied) into the fryer drain valve (Fig.
— 8 — SHORTENING MAINTENANCE Shortening life may be extended by following these important procedures. Do not salt foods over the fryer. Use good quality shortening. Filter shortening daily at a minimum. Keep equipment and surroundings clean. Set thermostats correctly.
— 9 — PL-40546-1 Reset Button 7. Turn power switch OFF at termination of burn-off cycle. 8. Heating elements will heat up in excess of 600 ° F glowing red. If any do not glow, call a Vulcan- authorized service agency. Some smoking, crackling sound and puffs of flame will occur.
— 10 — 6. Drain solution and discard. Close drain valve and fill tank half full with water. 7. Scrub entire inside of tank with a stiff bristle nylon brush. 8. Drain solution and rinse tank thoroughly with clean water. 9. Close drain valve and refill tank with clean hot (minimum 140 ° F) water.
— 11 — MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE PERFORMING ANY MAINTENANCE. CALIBRATION PROCEDURES 1. Monitor shortening temperature 1" below the surface with an accurate temperature measuring device.
— 12 — FORM 30729 Rev. A (1-95) PRINTED IN US.A..
Een belangrijk punt na aankoop van elk apparaat Vulcan-Hart SPER2 ML-52919 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vulcan-Hart SPER2 ML-52919 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vulcan-Hart SPER2 ML-52919 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vulcan-Hart SPER2 ML-52919 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vulcan-Hart SPER2 ML-52919 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vulcan-Hart SPER2 ML-52919 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vulcan-Hart SPER2 ML-52919 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vulcan-Hart SPER2 ML-52919 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.