Gebruiksaanwijzing /service van het product EM00-GATE-0000 van de fabrikant Watlow Electric
Ga naar pagina of 28
EM Gateway User’s Manual For Watlow part number EM00-GATE-0000 1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580 Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507, Internet: http://www.
2 EM Gateway Table of Contents Chapter 1: Product Overvi ew 4 Ethernet Gateway 4 Ethernet Gateway Architecture 4 Program Upgrades 5 Chapter 2: Installation and Wiring 6 Dimensions 7 Chapter 3: Configu.
3 EM Gateway Table of Contents – cont. Chapter 6: Reference Documents 25 Reference Documents 25 Serial Numbers 25 Chapter 7: Specifications 26 Power Supply 26 Environmental 26 Indication 26 Agency 2.
4 Chapter One Product Overview The EM00-GATE-0000 is a gateway / bridge that allo ws up to 32 Watlow controllers to be directly connected to an Ethernet network. Using an HTTP Brow ser such as Microsoft Internet Explorer or Netscape Navigator you may access 16 controllers and view several controllers’ parameters via an onboard Web (HTTP) server.
5 Program Upgrades The gateway has a TFTP server for the purposes of reprogramming the program memory. A program update will be initiated when a TFTP client, residing on a PC, begins to write a new program file to the gateway TFTP server. When reprogramming the progr am memory, all other gateway services are unavailable.
6 Chapter Two Installation & Wiring UL Approved, Class 2 power supply required.
7 Dimensions are in inches.
8 Chapter Three Configuration Getting Started Perform these steps; 1. Connect the EM00-GATE-0000 gateway to your com puter’s Ethernet port using a cross-wired RJ45 cable or connect the EM00-GATE-0000 to a hub or net work using a straight wired RJ45 Category 5 cable.
9 You will need to configure your Gateway with your SMTP server name or address. A DNS server address must also be configured if using a SMTP name. Contac t your system administrator if you don’t know the SMTP name or address. Data Logging The gateway provides no explicit means of data logging.
10 Chapter Four HTML Pages The section describes the pages availabl e from the EM Gateway’s Web server. When the web page is first accessed, you are prom pted for a User name and Password. The default User name is ‘new’. The default Password is ‘user’.
11 Use this page to disable or enable automatic page refreshing or to change the time in between refreshes. In addition, you can force a rescan of the Modbus Ne twork. This will cause the Gateway to detect any new devices added to the serial network. Set the baud rate of the network to 9600 or 19200-baud.
12 Use this page to change the Gateway identificati on name or to change the IP Address Resolution Method. Contact your IS administrator for questions regarding these settings.
13 Use this page to enable notification and configure the addresses for email recipients. These recipients will receive an email when an alarm occurs on any c ontroller.
14 Use this page to update the time and date stored in the Gateway. This information is used to identify the time and date of alarms when emails are sent.
15 1 0 0 0 0 1174 0 2 0 0 0 0 1174 0 3 0 0 0 0 1174 0 4 0 0 0 0 1174 0 5 0 0 0 0 1174 0 6 0 0 0 0 1174 0 7 0 0 0 0 1174 0 8 0 0 0 0 1174 0 9 0 0 0 0 1174 0 10 0 0 0 0 1174 0 11 5 2 0 3 1167 0 12 0 0 0.
16 This page was loaded Wed Feb 1318: 00:28 2002 IP Address 7.3.37.91 Subnet 255.255.224.0 Gateway 7.3.63.250 Mac Address 00:03:AA:00:00:C1 Receives 128349 Unicasts 1207 Multicasts 0 Broadcasts 127061 Rx Errors 0 Rx Missed 2089 Rx CRC Errors 28 Rx Drops 0 Transmits 1251 Buffer Defers 0 Tx Errors 0 Tx Collisions 0 Tx Coll.
17 Chapter Five Controller Parameters and Registers The EM Gateway supports the following parameter s for each type of controller when using an HTTP browser: Series 96 – non-ramping Operation Mode .
18 Series 988 / 989 Operation Mode – register 10 with choice of Auto or Manual as read only Input Error – register 4 with choice of Sensor Error or Ok as read only Process Value Input 1 – regist.
19 Series F4P Operation Mode – register 200 with choice of Auto or Manual as read only Input 1 Error – register 101 with choice of Sensor Error or Ok as read only Input 2 Error – register 105 wi.
20 CLS200 Series (Loop 1 to 16 if available) Operation Mode – register 264 to 279 with choice of Auto or Manual as read only Input Error – registers 660 to 675 with choice of Ok, TC Reversed, TC S.
21.
22.
23.
24.
25 Chapter Six Reference Documents The MODBUS RTU specification is located at: http://www.modicon.com/techpubs/toc7.html or http://www.modbus.org Serial Numbers Gateways are labeled with a unique serial number in numeric and bar code formats. The serial number is embedded in the gateway firmware.
26 Chapter Seven Specifications Pow er supply • Voltage input 24 V (ac/dc) +10%, -15% 50/60 Hz +/- 5 • Connection through 2-position removable screw style terminal block • 22 to 12 AWG • Power.
27 Declaration of Conformity Gateway Products Watlow Winona, Inc. 1241 Bundy Blvd. Winona, MN 55987 USA Declares that the following product: Model Numbers: EM00-GATE-0000, NGW0-0000-2400 and NGW0-0000.
28 How to Reach Us Technical Assistance If you encounter a problem with your EM Gateway, revi ew all of your wiring and configuration information to verify that your selections ar e consistent with your application.
Een belangrijk punt na aankoop van elk apparaat Watlow Electric EM00-GATE-0000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Watlow Electric EM00-GATE-0000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Watlow Electric EM00-GATE-0000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Watlow Electric EM00-GATE-0000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Watlow Electric EM00-GATE-0000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Watlow Electric EM00-GATE-0000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Watlow Electric EM00-GATE-0000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Watlow Electric EM00-GATE-0000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.