Gebruiksaanwijzing /service van het product Remote Power Boot Switch van de fabrikant Western Telematic
Ga naar pagina of 12
WTI Part No.: 12651 Rev. B RPB+ Remote Power Boot Switch User's Guide 5 Sterling, Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com Table of Contents 1. Introduction ● 2. Unit Description 2.
A. Specifications ● B. Customer Service ● List of Figures 1. Front Panel ● 2. Back Panel ● 3. RS-232 (Control Port) Interface Schematic ● 4. RPB+ Cable Connections ● 5. The Status Screen ● 1. Introduction Network equipment sometimes "locks-up", making it impossible to communicate.
Throughout this manual, typefaces and characters have been used to denote the following: COURIER FONT Indicates characters typed on the keyboard. For example, /S or /3 ON . [Bold Font] Text set in bold face and enclosed in square brackets indicates a specific key.
Switched AC Outlets (Plugs 1 - 5): For connection to up to five AC devices. Each outlet is capable of switching up to 15 Amps. The total for all five outlets must not exceed 15 Amps.
allows the user to invoke On/Off/Boot commands, but prevents redefinition of parameters such as the Password and Power-Up Default. Switch Function Up Down 1 Control Port Baud Rate 2400 bps 9600 bps* 2 Off Time 10 sec. 5 sec.* 3 Password Function Disable Enable* 4 Read Only Mode Enable Disable* * = Factory Setting 3.
string. 3.3. Power Connection The Power Switch located on the back panel must be "On" in order for the RPB+ to operate. Each time the unit is powered On, the five AC outlets will be switched On or Off, as dictated by the Power-Up Default String (see Section 4.
Password: If the Password function is enabled, the unit will display a prompt. Key in the Password and press [Enter] . If the password has not yet been defined, just press [Enter] .
during password definition. Default (Power-Up Default): Allows the user to define default On/Off conditions for each switched plug as described in Section 4.
Example 1: To set default On/Off conditions as follows: ON: Plugs 1 and 5 OFF: Plugs 2, 3, and 4 The Power-Up Default String would be defined as " 10001 ". Example 2: To set default plug conditions as follows: ON: Plugs 3, 4, and 5 OFF: Plugs 1 and 2 The Power-Up Default String would be defined as " 00111 ".
Enter Parameters: To define parameters, such as the Location I.D., Power-Up Default, and Plug Labels, type /P [Enter] and refer to Section 4 , Step 4. 5. Set Plugs to Default: To set all plugs to the Power-Up Defaults, type /D [Enter] . Note that if the Default String includes missing or invalid characters, the /D command will not function.
2 RXD Data Input 3 TXD Data Output 4 DTR Ready Output 5 GND Signal Ground 6 (NC) Not Connected 7 RTS RTS Output 8 (NC) Not Connected 9 (NC) Not Connected Coding: Asynchronous.
Irvine, California 92618 Toll Free (U.S. & Canada): 1-800-854-7226 Phone: 949-586-9950 Fax: 949-583-9514 EMail: service@wti.com FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and 1.
Een belangrijk punt na aankoop van elk apparaat Western Telematic Remote Power Boot Switch (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Western Telematic Remote Power Boot Switch heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Western Telematic Remote Power Boot Switch vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Western Telematic Remote Power Boot Switch leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Western Telematic Remote Power Boot Switch krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Western Telematic Remote Power Boot Switch bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Western Telematic Remote Power Boot Switch kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Western Telematic Remote Power Boot Switch . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.