OWNER’S MANUAL 1200/2000/3000 W A TT SERIES HIGH SURGE POWER INVERTERS THE WHISTLER GROUP , INC. CORPORA TE HEADQUARTERS 13016 N. W alton Blvd. Bentonville, AR 72712 TEL (479) 273-6012 FX (479) 273-2927 www .whistlergr oup.com CUSTOMER RETURN CENTER 1201 N.
1 If you have questions concerning the operation of this Whistler product please call customer service: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place. Y ou may r egister your pr oduct online at www .
WHISTLER FEA TURES A Wor d About Whistler Power Inverters Whistler inverters convert low voltage, direct curr ent (DC) t o 1 10 volt alternating household current (AC). The AC output i s c al l ed “modified sine wave”. See “T echnical Operating Princ iples” section for more information.
FEA TURES 5 FEA TURES 4 2000 watt series shown 3000 watt series shown.
FEA TURES a). ON/OFF Switch. This switch controls the flow of power from the power source to the inverter . It does not control the power running from the inverter to the equipment or appliance being operated. b). High T emperature LED Indicator Light.
INVERTER INFORMA TION I I m m p p o o r r t t a a n n t t I I n n f f o o r r m m a a t t i i o o n n About Y our New Whistler Inverter . This manual will provide you with dir ections for the safe and efficient operation of your Whistle Power Inverter .
start up load ratings comparable to your inverter wattage rating will not damage it. If a piece of equipment or an appliance will not operate, first confirm that the inverter has been properly connected to the 12 volt power source (See "Making The Connection").
13 BA TTER Y/CABLE INFORMA TION • It may be advisable to operate the inverter from a bank of batteries of the same type in a "parallel" configuration. T wo such batteries will generate twice the amp/hours of a single battery; three batteries will generate thr ee times the amp/hours and so on.
Adapter ." Use of #0 gauge wire to make the connections to the inverter may requir e a "0 to 4 Gauge Adapter ." Both adapters are available thr ough electronic supply stor es including Radio Shack.
17 16 OPERA TION OPERA TION 7. T urn the inverter ON (I). Check the Meter on the front panel. The V oltage should read between 11 and 14 volts depending on the voltage of the power source.
OPERA TION OPERA TION 18 • Check fr equently to ensure that the input and output connections are secur e. Loose connections may damage the inverter , the power source, or may generate excessive heat. • The following pr ecautions apply to the 3000 watt models only .
21 20 OPERA TION OPERA TION and typically is refer enced on the back of the microwave. If the operating power requir ement does not appear on the back of the microwave, check the owner’ s manual or contact the manufacturer . Some Powerful Advice. Y our W his tle r inverter will work best when placed on a reasonably flat surface.
OPERA TING PRINCIP ALS 23 22 OPERA TION r a d i a t o r s o r o t h e r sources of heat. Do not place the inverter in direct sunlight. • VENTILA TION. In order to disperse the heat generated while the inverter is in operation, keep it well ventilated.
OPERA TION SUMMAR Y • Before attempting to use a battery char ger see page 19. • Before attempting to use medical equipment see page 8. • Use the heaviest gauge wire (smaller the number , the larger or heavier the cable) available to connect the inverter to the power source.
TROUBLESHOOTING 27 PROBLEM: TV Interference Problem Solution Electrical interference fr om Add a Ferrite data line filter inverter . on to the TV power cord. This filter is available at RadioShack, or other electronic supply stor es. part number 273-105.
SPECIFICA TION WHISTLER 1200 WA TT INVER TER SPECIFICA TIONS Maximum Continuous Power……………………………1200 W atts Maximum Surge Capability (Peak Power).....................2400 W atts * * No Load Current Draw……………………………….
W ARRANTY IMPORT ANT : Whistler will not assume responsibility for loss or damage incurred in shipping. Ther efore, please ship your inverter insured with r eturn receipt requested. 2. Include with your unit the following information, clearly printed: • Y our name and street address (for shipping via UPS), a daytime telephone number , (No P .
MEMO 33 32 W ARRANTY The out of warranty service fee for your 1200 Whistler inverter is $90.00, 2000 Whistler inverter is $150.00 and 3000 Whistler inverter is $250.
Een belangrijk punt na aankoop van elk apparaat Whistler 3000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Whistler 3000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Whistler 3000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Whistler 3000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Whistler 3000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Whistler 3000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Whistler 3000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Whistler 3000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.