Ga naar pagina of 12
1 Blue 2” Heat Pump Ther mostat Heat Pump or Single Stage Installation and Operating Instructions Save these instructions f or future use! F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMA GE.
2 REMO VE OLD THERMOST A T 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remov e the front cov er of the old thermostat. With wires still attached , remov e wall plate from the w all.
3 INST ALLA TION install fresh “AA” alkaline batteries immediately . For best results, use ne w premium brand alkaline batteries such as Duracell® or Energizer®.
4 WIRING DIA GRAMS L R C SYSTEM MONITOR SWITCH G W2 Figure 4. T ypical wiring diagram for tw o transformer systems with saf ety circuits in BO TH systems Changeov er Relay* Y O/B Compressor Contactor .
5 The confi guration menu allo ws you to set certain ther mostat operating characteristics to your system or personal requirements. T o enter the menu: Set your thermostat to OFF and press the and b uttons simultaneously . The display will show the fi rst item in the confi guration menu.
6 Emergency System EMER bypasses the Heat Pump to use the heat source wired to terminal W2 on the ther mostat. EMER is typically used when compressor operation is not desired, or y ou prefer bac k-up heat only . 1. Mo ve SYSTEM s witch to EMER position, EMER will fl ash on the displa y .
7 Do not allow the compressor to run unless the compressor oil heaters ha ve been operational for 6 hours and the system has not been operational f or at least 5 minutes. CA UTION ! MANU AL OPERA TION • HOLD TEMPERA TURE — With the SYSTEM s witch set to HEA T or COOL , momentarily press R UN/HOLD button.
8 PR OGRAMMING Enter Heating Program 1. Mov e the SYSTEM switch to HEA T . 2. Press PRGM once. “Mo T u We Th Fr” (indicating weekda y program) will appear in the displa y . Also displa yed are the currently programmed start time for the 1st heating period and the currently programmed temper ature (fl ashing).
9 TR OUBLESHOO TING Reset Operation If a voltage spik e or static discharge blanks out the displa y or causes erratic thermostat operation, reset the ther mostat by pressing the , and PRGM buttons sim ultaneously .
10 ST A GING Second Stage - A uxiliary Heat Most heat pump systems hav e an A uxiliar y or Second Stage electric heater or gas fur nace. Heat produced by a heat pump is economical but ma y not alwa ys ha ve the capacity to maintain a comf or table room temperature setting.
11 NO TES.
12 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mar k of Emerson Electric Co. Homeowner Help Line: 1-800-284-2925 www .
Een belangrijk punt na aankoop van elk apparaat White Rodgers 1F82-0261 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen White Rodgers 1F82-0261 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens White Rodgers 1F82-0261 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding White Rodgers 1F82-0261 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over White Rodgers 1F82-0261 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van White Rodgers 1F82-0261 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de White Rodgers 1F82-0261 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met White Rodgers 1F82-0261 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.