Blue Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Model Programming Choices 1F95-0671 7 Day 5/1/1 Day Non-Programmab le www .
2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base.
3 WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransf ormer Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Co.
4 Single Stage 3-wire Zone V alve application Blower/Circulator Fan Energized Opens Va l v e (4) Constant 24 V olt (Com- mon) 24 V olt (Hot) Cool System 6 Y W C RC CLASS II TRANSFORMER HOT 24V AC NEUT.
5 Programming and Confi guration Items 1 "System On" indicates when heating or cooling stage is energized. "System On +2" indicates when addi tional stages are on. 2 The word " Hold" is displayed when the thermostat is in the HOLD mode.
6 INST ALLER/CONFIGURA TION MENU Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below . Press Menu to advance to the next menu item. Press or to change a menu item options.
7 INST ALLER/CONFIGURA TION MENU 21 20 18 MENU dS (On) Off Selects A utomatic Daylight Sa ving Time option 22 21 19 MENU (OFF) K eypad Lock out L, P , Limit Selects one of 3 K eypad Lock out confi gu.
8 INST ALLER/CONFIGURA TION MENU 5, 6 & 7) Cycle Rate Selection – The f actor y def ault setting for Heat and Cool modes, SS1, MS2, is medium cycle (ME). F or Heat Pump , HP1, HP2, the default setting is medium (ME). For Emer (A ux) the default setting is f ast cycle (F A).
9 INST ALLER/CONFIGURA TION MENU 24) Limited Cool Range – This f eature provide a minimum setpoint temperature f or cool. The default setting is 45°F .
10 T o pre vent compressor and/or property damage, if the outdoor temperature is below 50°F , DO NO T operate the cooling system. CAUTION ! Cooling System 1. Press SYSTEM b utton to select Cool. 2. Press to adjust thermostat setting below room tem- perature.
11 PR OGRAMMING Energy Sa ving Factory Pre-Pr ogram The 1F95-0680 thermostats are programmed with the energy saving settings sho wn in the table belo w for all da ys of the week. If this program suits y our needs, simply set the ther mostat clock and press the RunSched b utton.
12 A utomatic Daylight Sa ving Calculation The Real Time Clock will adjust automatically f or da ylight sav- ings time, in the f ollowing manner : Increment one hour at 2 AM on the second Sunda y of March and decrement one hour at 2 AM on the fi rst Sunda y of No- vember .
13 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T er minals +, S and - on the terminal block allo w connection of the remote sensor .
14 Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system.
15 NO TES.
www.white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925.
Een belangrijk punt na aankoop van elk apparaat White Rodgers 1F95-0671 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen White Rodgers 1F95-0671 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens White Rodgers 1F95-0671 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding White Rodgers 1F95-0671 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over White Rodgers 1F95-0671 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van White Rodgers 1F95-0671 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de White Rodgers 1F95-0671 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met White Rodgers 1F95-0671 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.